Gait Adaptation Using a Cable-Driven Active Leg Exoskeleton (C-ALEX) With Post-Stroke Participants

被引:46
作者
Hidayah, Rand [1 ]
Bishop, Lauri [2 ]
Jin, Xin [1 ]
Chamarthy, Siddharth [1 ]
Stein, Joel [3 ]
Agrawal, Sunil K. [3 ,4 ]
机构
[1] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
[2] Univ Southern Calif, Dept Biokinesiol & Phys Therapy, Los Angeles, CA 90089 USA
[3] Columbia Univ, Med Ctr, Dept Rehabil & Regenerat Med, New York, NY 10032 USA
[4] Columbia Univ, Dept Mech Engn, New York, NY 10027 USA
关键词
Assistive technology; medical robotics; rehabilitation robotics; exoskeleton; wearable robots; COGNITIVE ASSESSMENT MOCA; STROKE; DIRECTIONS; DESIGN;
D O I
10.1109/TNSRE.2020.3009317
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Individuals with chronic hemiparesis post-stroke exhibit gait impairments that require functional rehabilitation through training. Exoskeletal robotic assistive devices can provide a user with continuous assistance but impose movement restrictions. There are currently devices that allow unrestricted movement but provide assistance only intermittently at specific points of the gait cycle. Our design, a cable-driven active leg exoskeleton (C-ALEX), allows the user both unrestricted movement and continuous force assistance throughout the gait cycle to assist the user in new walking patterns. In this study, we assessed the ability of C-ALEX to induce a change in the walking patterns of ten post-stroke participants using a single-session training protocol. The ability of C-ALEX to accurately provide forces and torques in the desired directions was also evaluated to compare its design performance to traditional rigid-link designs. Participants were able to reach 91% +/- 12% of their target step length and 89% +/- 13% of their target step height. The achieved step parameters differed significantly from participant baselines (p < 0.05). To quantify the performance, the forces in each cable's out of the plane movements were evaluated relative to the in-plane desired cable tension magnitudes. This corresponded to an error of under 2Nm in the desired controlled joint torques. This error magnitude is low compared to the system command torques and typical adult biological torques during walking (2-4%). These results point to the utility of using non-restrictive cable-driven architectures in gait retraining, in which future focus can be on rehabilitating gait pathologies seen in stroke survivors.
引用
收藏
页码:1984 / 1993
页数:10
相关论文
共 50 条
[11]   Motor learning after stroke: Is skill acquisition a prerequisite for contralesional neuroplastic change? [J].
Boyd, Lara A. ;
Vidoni, Eric D. ;
Wessel, Brenda D. .
NEUROSCIENCE LETTERS, 2010, 482 (01) :21-25
[12]   Recent developments and challenges of lower extremity exoskeletons [J].
Chen, Bing ;
Ma, Hao ;
Qin, Lai-Yin ;
Gao, Fei ;
Chan, Kai-Ming ;
Law, Sheung-Wai ;
Qin, Ling ;
Liao, Wei-Hsin .
JOURNAL OF ORTHOPAEDIC TRANSLATION, 2016, 5 :26-37
[13]   Overground vs. treadmill-based robotic gait training to improve seated balance in people with motor-complete spinal cord injury: a case report [J].
Chisholm, Amanda E. ;
Alamro, Raed A. ;
Williams, Alison M. M. ;
Lam, Tania .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2017, 14
[14]   Knee joint forces: prediction, measurement, and significance [J].
D'Lima, Darryl D. ;
Fregly, Benjamin J. ;
Patil, Shantanu ;
Steklov, Nikolai ;
Colwell, Clifford W., Jr. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H2) :95-102
[15]   Effects of hip abduction and adduction accuracy on post-stroke gait [J].
Dean, Jesse C. ;
Embry, Aaron E. ;
Stimpson, Katy H. ;
Perry, Lindsay A. ;
Kautz, Steven A. .
CLINICAL BIOMECHANICS, 2017, 44 :14-20
[16]   Randomized clinical trial of therapeutic exercise in subacute stroke [J].
Duncan, P ;
Studenski, S ;
Richards, L ;
Gollub, S ;
Lai, SM ;
Reker, D ;
Perera, S ;
Yates, J ;
Koch, V ;
Rigler, S ;
Johnson, D .
STROKE, 2003, 34 (09) :2173-2180
[17]  
Eng Janice J, 2007, Expert Rev Neurother, V7, P1417, DOI 10.1586/14737175.7.10.1417
[18]  
Han HX, 2017, IEEE INT CON MULTI, P1177, DOI 10.1109/ICME.2017.8019424
[19]   Walking With Augmented Reality: A Preliminary Assessment of Visual Feedback With a Cable-Driven Active Leg Exoskeleton (C-ALEX) [J].
Hidayah, Rand ;
Chamarthy, Siddharth ;
Shah, Avni ;
Fitzgerald-Maguire, Matthew ;
Agrawal, Sunil K. .
IEEE ROBOTICS AND AUTOMATION LETTERS, 2019, 4 (04) :3948-3954
[20]  
Hidayah R, 2018, P IEEE RAS-EMBS INT, P299, DOI 10.1109/BIOROB.2018.8487771