Slice Profile and B1 Corrections in 2D Magnetic Resonance Fingerprinting

被引:130
|
作者
Ma, Dan [1 ]
Coppo, Simone [1 ]
Chen, Yong [1 ]
McGivney, Debra F. [1 ]
Jiang, Yun [2 ]
Pahwa, Shivani [1 ]
Gulani, Vikas [1 ]
Griswold, Mark A. [1 ]
机构
[1] Case Western Reserve Univ, Dept Radiol, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Biomed Engn Dept, Cleveland, OH 44106 USA
关键词
MR fingerprinting; T-1; T-2; slice profile correction; B-1; correction; STATE FREE PRECESSION; STEADY-STATE; HUMAN BRAIN; RADIOFREQUENCY FIELD; PULSE DESIGN; RECONSTRUCTION; EXCITATION; ACCURATE; DENSITY; SIGNAL;
D O I
10.1002/mrm.26580
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The goal of this study is to characterize and improve the accuracy of 2D magnetic resonance fingerprinting (MRF) scans in the presence of slice profile (SP) and B-1 imperfections, which are two main factors that affect quantitative results in MRF. Methods: The SP and B-1 imperfections are characterized and corrected separately. The SP effect is corrected by simulating the radiofrequency pulse in the dictionary, and the B-1 is corrected by acquiring a B-1 map using the Bloch-Siegert method before each scan. The accuracy, precision, and repeatability of the proposed method are evaluated in phantom studies. The effects of both SP and B-1 imperfections are also illustrated and corrected in the in vivo studies. Results: The SP and B-1 corrections improve the accuracy of the T-1 and T-2 values, independent of the shape of the radiofrequency pulse. The T-1 and T-2 values obtained from different excitation patterns become more consistent after corrections, which leads to an improvement of the robustness of the MRF design. Conclusion: This study demonstrates that MRF is sensitive to both SP and B-1 effects, and that corrections can be made to improve the accuracy of MRF with only a 2-s increase in acquisition time. (C) 2017 International Society forMagnetic Resonance inMedicine.
引用
收藏
页码:1781 / 1789
页数:9
相关论文
共 50 条
  • [31] Comprehensive Evaluation of B1+-corrected FISP-based Magnetic Resonance Fingerprinting: Accuracy, Repeatability and Reproducibility of T1 and T2 Relaxation Times for ISMRM/NIST System Phantom and Volunteers
    Kato, Yutaka
    Ichikawa, Kazushige
    Okudaira, Kuniyasu
    Taoka, Toshiaki
    Kawaguchi, Hirokazu
    Murata, Katsutoshi
    Maruyama, Katsuya
    Koerzdoerfer, Gregor
    Pfeuffer, Josef
    Nittka, Mathias
    Naganawa, Shinji
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2020, 19 (03) : 168 - 175
  • [32] MUPen2DTool: A new Matlab Tool for 2D Nuclear Magnetic Resonance relaxation data inversion
    Bortolotti, Villiam
    Brizi, Leonardo
    Nagmutdinova, Anastasiia
    Zama, Fabiana
    Landi, Germana
    SOFTWAREX, 2022, 20
  • [33] Simultaneous T-1 and T-2 Brain Relaxometry in Asymptomatic Volunteers Using Magnetic Resonance Fingerprinting
    Badve, Chaitra
    Yu, Alice
    Rogers, Matthew
    Ma, Dan
    Liu, Yiying
    Schluchter, Mark
    Sunshine, Jeffrey
    Griswold, Mark
    Gulani, Vikas
    TOMOGRAPHY, 2015, 1 (02) : 136 - 144
  • [34] Rapid Radial T1 and T2 Mapping of the Hip Articular Cartilage With Magnetic Resonance Fingerprinting
    Cloos, Martijn A.
    Asslander, Jakob
    Abbas, Batool
    Fishbaugh, James
    Babb, James S.
    Gerig, Guido
    Lattanzi, Riccardo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (03) : 810 - 815
  • [35] Mapping and characterizing endometrial implants by registering 2D transvaginal ultrasound to 3D pelvic magnetic resonance images
    Yavariabdi, Amir
    Bartoli, Adrien
    Samir, Chafik
    Artigues, Maxime
    Canis, Michel
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2015, 45 : 11 - 25
  • [36] Novel 3D magnetic resonance fingerprinting radiomics in adult brain tumors: a feasibility study
    Tippareddy, Charit
    Onyewadume, Louisa
    Sloan, Andrew E.
    Wang, Gi-Ming
    Patil, Nirav T.
    Hu, Siyuan
    Barnholtz-Sloan, Jill S.
    Boyacioglu, Rasim
    Gulani, Vikas
    Sunshine, Jeffrey
    Griswold, Mark
    Ma, Dan
    Badve, Chaitra
    EUROPEAN RADIOLOGY, 2023, 33 (02) : 836 - 844
  • [37] Accelerated white matter lesion analysis based on simultaneous T1 and T2* quantification using magnetic resonance fingerprinting and deep learning
    Hermann, Ingo
    Martinez-Heras, Eloy
    Rieger, Benedikt
    Schmidt, Ralf
    Golla, Alena-Kathrin
    Hong, Jia-Sheng
    Lee, Wei-Kai
    Wu Yu-Te
    Nagtegaal, Martijn
    Solana, Elisabeth
    Llufriu, Sara
    Gass, Achim
    Schad, Lothar R.
    Weingaertner, Sebastian
    Zoellner, Frank G.
    MAGNETIC RESONANCE IN MEDICINE, 2021, 86 (01) : 471 - 486
  • [38] Nanoscale magnetic field imaging for 2D materials
    Marchiori, Estefani
    Ceccarelli, Lorenzo
    Rossi, Nicola
    Lorenzelli, Luca
    Degen, Christian L.
    Poggio, Martino
    NATURE REVIEWS PHYSICS, 2022, 4 (01) : 49 - 60
  • [39] Magnetic resonance fingerprinting for simultaneous renal T1 and T2*mapping in a single breath-hold
    Hermann, Ingo
    Chacon-Caldera, Jorge
    Brumer, Irene
    Rieger, Benedikt
    Weingartner, Sebastian
    Schad, Lothar R.
    Zoellner, Frank G.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (06) : 1940 - 1948
  • [40] Accelerating Parallel Transmit Array B1 Mapping in High Field MRI With Slice Undersampling and Interpolation by Kriging
    Ferrand, Guillaume
    Luong, Michel
    Cloos, Martijn A.
    Amadon, Alexis
    Wackernagel, Hans
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (08) : 1726 - 1734