Postoperative Results after Implantation of a Toric, Aspheric Intraocular Lens

被引:5
作者
Khoramnia, R. [1 ,2 ]
Fitting, A.
Rabsilber, T. M.
Auffarth, G. U.
Holzer, M. P.
机构
[1] Univ Augenklin Heidelberg, IVCRC, D-69120 Heidelberg, Germany
[2] David J Apple Int Lab Ocular Pathol, D-69120 Heidelberg, Germany
关键词
IOL; toric; aspheric; aberration-neutral; cataract; refractive surgery; CATARACT-SURGERY; ROTATIONAL STABILITY; SINGLE-PIECE; CORNEAL ASTIGMATISM; MULTICENTER; EXTRACTION; MODERATE; OUTCOMES; EYES;
D O I
10.1055/s-0034-1396179
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Zusammenfassung Hintergrund: Ziel der Studie war eine klinische Evaluation der funktionellen Ergebnisse und Sehqualitat nach Implantation einer aspharischen, aberrationsneutralen, torischen Intraokularlinse (IOL). Patienten und Methoden: 18 Augen von 13 Patienten wurden in diese prospektive Studie eingeschlossen. Die T-flex aspharische, aberrationsfreie torische IOL (Rayner Intraocular Lenses Limited, UK) wurde nach Femtosekundenlaser- oder Standard-Phakoemulsifikation implantiert. Verlaufskontrollen wurden 2 bis 4 Monate postoperativ durchgefuhrt und beinhalteten subjektive Refraktion, unkorrigierten (UDVA) und bestkorrigierten (CDVA) Fernvisus, Wellenfrontanalyse, Streulichtanalyse (C-Quant) und einen Fragebogen. Ergebnisse: Postoperativ betrug der UDVA im Median 0,06 logMAR (0,30 bis -0,18 logMAR). Der CDVA stieg im Median von 0,20 logMAR (0,64 bis 0,00 logMAR) auf -0,07 logMAR (0,16 bis -0,26 logMAR) an. Die Differenz zwischen dem erreichten und intendierten spharischen Aquivalent betrug im Median -0,08dpt (-1,25 bis +0,65dpt). Der mediane subjektive Zylinder verringerte sich von praoperativ -2,00dpt (-6,50 bis -0,25dpt) auf -0,50dpt (-1,25 bis 0,00dpt) nach der Operation. Die spharischen Aberrationen (6mm Pupillengro ss e) betrugen postoperativ im Median -0,38 mu m (-0,69 bis -0,10 mu m). Die Streulichtanalyse mittels C-Quant ergab im Median einen Wert von 1,28 log(s) (0,92 bis 1,61 log[s]). Schlussfolgerung: Die T-flex aspharische torische IOL liefert postoperativ gute funktionelle Ergebnisse. Die Implantation der T-flex ist eine effektive Methode zur Korrektur von Astigmatismen uber einen gro ss en Bereich. Abstract Purpose: The purpose of this study was to evaluate the functional results and quality of vision after implantation of an aspheric, aberration-neutral, monofocal toric intraocular lens (IOL). Patients and Methods: 18 eyes of 13 patients were enrolled in this prospective clinical study. The T-flex aspheric, aberration-free toric IOL (Rayner Intraocular Lenses Limited, U.K.) was implanted after femtosecond or standard phacoemulsification. Follow-up examinations were performed two to four months after surgery; these included subjective refraction, ETDRS uncorrected (UDVA) and corrected distance visual acuity (CDVA), wavefront analysis, measurements of stray light (C-Quant), and a questionnaire. Results: Median UDVA was 0.06 logMAR (range: 0.30 to -0.18 logMAR) postoperatively. Median CDVA increased from 0.20 logMAR (range: 0.64 to 0.00 logMAR) preoperatively to -0.07 logMAR (range: 0.16 to -0.26 logMAR) postoperatively. The median difference between achieved versus intended spherical equivalent was -0.08 D (range: -1.25 to +0.65 D). Median subjective cylinder improved from -2.00 D (range: -6.50 to -0.25 D) preoperatively to -0.50 D (range: -1.25 to 0.00 D) postoperatively. The median spherical aberrations (6mm pupil size) were -0.38 mu m (range: -0.69 to -0.10 mu m) postoperatively. Measurements of stray light (C-Quant) revealed a median value of 1.28 log(s) (range: 0.92 to 1.61 log[s]). Conclusion: The T-flex aspheric toric IOL provided beneficial and predictable functional results after surgery. The implantation of the T-flex is an effective method to correct a large range of corneal astigmatism.
引用
收藏
页码:867 / 873
页数:7
相关论文
共 28 条
[21]   Rotational stability of a single-piece toric acrylic intraocular lens [J].
Koshy, John J. ;
Nishi, Yutaro ;
Hirnschall, Nino ;
Crnej, Alja ;
Gangwani, Vinod ;
Maurino, Vincenzo ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10) :1665-1670
[22]   Evaluation of the long-term rotational stability of single-piece, acrylic intraocular lenses [J].
Kwartz, J. ;
Edwards, K. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (08) :1003-1006
[23]   Comparison of Clinical and Patient-reported Outcomes With Bilateral AcrySof Toric or Spherical Control Intraocular Lenses [J].
Lane, Stephen S. ;
Ernest, Paul ;
Miller, Kevin M. ;
Hileman, Kendra S. ;
Harris, Blake ;
Waycaster, Curtis R. .
JOURNAL OF REFRACTIVE SURGERY, 2009, 25 (10) :899-901
[24]   Differences in contrast sensitivity between monofocal, multifocal and accommodating intraocular lenses: long-term results [J].
Mesci, Cem ;
Erbil, Hasan H. ;
Olgun, Ali ;
Aydin, Nihat ;
Candemir, Bahadir ;
Akcakaya, Aylin A. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (08) :768-777
[25]   Refractive error and visual outcome after cataract extraction [J].
Murphy, C ;
Tuft, SJ ;
Minassian, DC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (01) :62-66
[26]  
Packer Mark, 2004, Curr Opin Ophthalmol, V15, P56, DOI 10.1097/00055735-200402000-00011
[27]   Effect of applanation tonometry on precision of biometry measurements [J].
Rabsilber, T. M. ;
Bueltmann, S. ;
Holzer, M. P. ;
Auffarth, G. U. .
OPHTHALMOLOGE, 2011, 108 (01) :52-+
[28]   Straylight effects with aging and lens extraction [J].
Van den Berg, Thomas J. T. P. ;
Van Rijn, L. J. ;
Michael, Ralph ;
Heine, Christian ;
Coeckelbergh, Tanja ;
Nischler, Christian ;
Wilhelm, Helmuth ;
Grabner, Guenther ;
Emesz, Martin ;
Barraquer, Rafael I. ;
Coppens, Joris E. ;
Franssen, Luuk .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (03) :358-363