Technological Barriers in the Use of Electrochemical Microsensors and Microbiosensors for in vivo Analysis of Neurological Relevant Substances

被引:11
作者
Bucur, Bogdan [1 ]
机构
[1] Natl Inst Res & Dev Biol Sci, Bioanal Ctr, Bucharest 060031, Romania
关键词
Brain in vivo analysis; microelectrodes; microbiosensors; neurotransmitters; neuromodulators; CARBON-FIBER MICROELECTRODES; SCAN CYCLIC VOLTAMMETRY; BRAIN-TISSUE; L-GLUTAMATE; RAT-BRAIN; NITRIC-OXIDE; MULTISITE MICROELECTRODES; DOPAMINE DETECTION; NEURONAL-ACTIVITY; PASTE ELECTRODES;
D O I
10.2174/157015912803217350
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
In this paper is presented an overview of the technological barriers faced by the in vivo brain analysis with microelectrodes. Numerous microsensors and enzymatic microbiosensors have been developed for the real time monitoring of neurotransmitters, neuromodulators, drugs and diverse other biological relevant substances. A clear understanding of the working principle, advantages and limitations is essential for the acquisition of valid data in neurological investigations. Some of the aspects presented here refer to: microelectrode insertion and positioning related to possibilities to minimize tissue damage, spatial and temporal resolution of the measurements, actual controversies in data interpretation and sensor calibration, simultaneous detection of multiple analytes, interferences and state of the art in the development of wireless devices.
引用
收藏
页码:197 / 211
页数:15
相关论文
共 94 条
[1]   Potassium-selective microelectrode revealed difference in threshold potassium concentration for cortical spreading depression in female and male rat brain [J].
Adamek, Svatopluk ;
Vyskocil, Frantisek .
BRAIN RESEARCH, 2011, 1370 :215-219
[2]   Independent positioning of microelectrodes for multisite recordings in vitro [J].
Albus, Klaus ;
Sinske, Kurt ;
Heinemann, Uwe .
JOURNAL OF NEUROSCIENCE METHODS, 2009, 176 (02) :182-185
[3]   Nitric oxide release during evoked neuronal activity in cerebellum slices: Detection with platinized carbon-fiber microelectrodes [J].
Amatore, C ;
Arbault, S ;
Bouret, Y ;
Cauli, B ;
Guille, M ;
Rancillac, A ;
Rossier, J .
CHEMPHYSCHEM, 2006, 7 (01) :181-187
[4]   Real-time amperometric analysis of reactive oxygen and nitrogen species released by single immunostimulated macrophages [J].
Amatore, Christian ;
Arbault, Stephane ;
Bouton, Cecile ;
Drapier, Jean-Claude ;
Ghandour, Hala ;
Koh, Alaric C. W. .
CHEMBIOCHEM, 2008, 9 (09) :1472-1480
[5]   Subsecond voltammetric separation between dopamine and serotonin in the presence of ascorbate [J].
Anastassiou, Costas A. ;
Patel, Bhavik A. ;
Arundell, Martin ;
Yeoman, Mark S. ;
Parker, Kim H. ;
O'Hare, Danny .
ANALYTICAL CHEMISTRY, 2006, 78 (19) :6990-6998
[6]   REGIONAL CEREBRAL GLUCOSE PHOSPHORYLATION AND BLOOD-FLOW AFTER INSERTION OF A MICRODIALYSIS FIBER THROUGH THE DORSAL HIPPOCAMPUS IN THE RAT [J].
BENVENISTE, H ;
DREJER, J ;
SCHOUSBOE, A ;
DIEMER, NH .
JOURNAL OF NEUROCHEMISTRY, 1987, 49 (03) :729-734
[7]   The brain tissue response to implanted silicon microelectrode arrays is increased when the device is tethered to the skull [J].
Biran, Roy ;
Martin, Dave C. ;
Tresco, Patrick A. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2007, 82A (01) :169-178
[8]   An in vitro characterisation comparing carbon paste and Pt microelectrodes for real-time detection of brain tissue oxygen [J].
Bolger, Fiachra B. ;
Bennett, Rachel ;
Lowry, John P. .
ANALYST, 2011, 136 (19) :4028-4035
[9]   Electrochemical nanoneedle biosensor based on multiwall carbon nanotube [J].
Boo, H ;
Jeong, RA ;
Park, S ;
Kim, KS ;
An, KH ;
Lee, YH ;
Han, JH ;
Kim, HC ;
Chung, TD .
ANALYTICAL CHEMISTRY, 2006, 78 (02) :617-620
[10]   Ceramic-based multisite microelectrode arrays for simultaneous measures of choline and acetylcholine in CNS [J].
Burmeister, Jason J. ;
Pomerleau, Francois ;
Huettl, Peter ;
Gash, Clelland R. ;
Wemer, Catherine E. ;
Bruno, John P. ;
Gerhardt, Greg A. .
BIOSENSORS & BIOELECTRONICS, 2008, 23 (09) :1382-1389