A long-range, high-resolution optical coherence tomography for physical and environmental measurements

被引:0
作者
Chou, Yu-Chung [1 ]
Wu, Chien-ming [1 ]
机构
[1] Natl TsingHua Univ, Dept Biomed Engn & Environm Sci, Hsinchu, Taiwan
关键词
Optical coherence tomography; Temperature-dependent refractive index; Water pollution measurement; REFRACTIVE-INDEX; INTERFEROMETER; COEFFICIENT;
D O I
10.1016/j.optcom.2012.02.077
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical coherence tomography (OCT) is an emerging optical imaging technique that is applied with low coherence interference to perform noninvasive, high-resolution images on internal and surface structures. In this study, we built an optical coherence system and developed a combined envelope-fringe and carrier-fringe technique that can take advantage of high-resolution and long-range for taking physical and environmental measurements. The proposed system demonstrated that the detection resolution of the changes of the refractive index was 1.89 x 10(-4) for the long-range set-up (i.e. using the envelope-fringe only), and 4.15 x 10(-5) for the high-resolution set-up (i.e. using the carrier-fringe). In addition, we successfully applied the system to measure the refractive index of a body of water, as the index for determining the pollution condition of different lakes. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:3246 / 3248
页数:3
相关论文
共 13 条
[1]  
Cheng L, 2004, THESIS CHUNG YUAN CH
[2]   Measurement of diffusion coefficient of transparent liquid solutions using Michelson interferometer [J].
Chhaniwal, VK ;
Anand, A ;
Narayanamurthy, CS .
OPTICS AND LASERS IN ENGINEERING, 2004, 42 (01) :9-20
[3]   In vivo ultrahigh-resolution optical coherence tomography [J].
Drexler, W ;
Morgner, U ;
Kärtner, FX ;
Pitris, C ;
Boppart, SA ;
Li, XD ;
Ippen, EP ;
Fujimoto, JG .
OPTICS LETTERS, 1999, 24 (17) :1221-1223
[4]   In vivo anterior segment imaging in the rat eye with high speed white light full-field optical coherence tomography [J].
Grieve, K ;
Dubois, A ;
Simonutti, M ;
Paques, M ;
Sahel, J ;
Le Gargasson, JF ;
Boccara, C .
OPTICS EXPRESS, 2005, 13 (16) :6286-6295
[5]   Three-dimensional imaging of the human retina by high-speed optical coherence tomography [J].
Hitzenberger, CK ;
Trost, P ;
Lo, PW ;
Zhou, QY .
OPTICS EXPRESS, 2003, 11 (21) :2753-2761
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   Accurate measurement of total attenuation coefficient of thin tissue with optical coherence tomography [J].
Kholodnykh, AI ;
Petrova, IY ;
Motamedi, M ;
Esenaliev, RO .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2003, 9 (02) :210-221
[8]   Ultrahigh resolution optical coherence tomography using a superluminescent light source [J].
Kowalevicz, AM ;
Ko, T ;
Hartl, I ;
Fujimoto, JG ;
Pollnau, M ;
Salathé, RP .
OPTICS EXPRESS, 2002, 10 (07) :349-353
[9]   Measurement of the refractive indices of H2SO4-HNO3-H2O solutions to stratospheric temperatures [J].
Krieger, UK ;
Mössinger, JC ;
Luo, BP ;
Weers, U ;
Peter, T .
APPLIED OPTICS, 2000, 39 (21) :3691-3703
[10]   Video-rate three-dimensional optical coherence tomography [J].
Laubscher, M ;
Ducros, M ;
Karamata, B ;
Lasser, T ;
Salathé, R .
OPTICS EXPRESS, 2002, 10 (09) :429-435