Experimental investigation of design parameters on dry powder inhaler performance

被引:16
|
作者
Nguyen Thi Quynh Ngoc [1 ]
Chang, Lusi [1 ]
Jia, Xinli [1 ]
Lau, Raymond [1 ]
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 639798, Singapore
关键词
Dry powder inhaler; Flow field; Turbulence intensity; In vitro deposition; Emitted dose; Fine particle fraction; COMPUTATIONAL FLUID-DYNAMICS; POLLEN-SHAPE CARRIER; AIR-FLOW; INHALATION PERFORMANCE; DRUG-DELIVERY; PARTICLE-SIZE; DEVICE DESIGN; FORMULATION; DISPERSION; DEPOSITION;
D O I
10.1016/j.ijpharm.2013.08.072
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The study aims to investigate the impact of various design parameters of a dry powder inhaler on the turbulence intensities generated and the performance of the dry powder inhaler. The flow fields and turbulence intensities in the dry powder inhaler are measured using particle image velocimetry (PIV) techniques. In vitro aerosolization and deposition a blend of budesonide and lactose are measured using an Andersen Cascade Impactor. Design parameters such as inhaler grid hole diameter, grid voidage and chamber length are considered. The experimental results reveal that the hole diameter on the grid has negligible impact on the turbulence intensity generated in the chamber. On the other hand, hole diameters smaller than a critical size can lead to performance degradation due to excessive particle-grid collisions. An increase in grid voidage can improve the inhaler performance but the effect diminishes at high grid voidage. An increase in the chamber length can enhance the turbulence intensity generated but also increases the powder adhesion on the inhaler wall. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 100
页数:9
相关论文
共 50 条
  • [41] The role of lactose carrier on the powder behavior and aerodynamic performance of bosentan microparticles for dry powder inhalation
    Lee, Hyo-Jung
    Lee, Hong-Goo
    Kwon, Yong-Bin
    Kim, Ju-Young
    Rhee, Yun-Seok
    Chon, Jinmann
    Park, Eun-Soek
    Kim, Dong-Wook
    Park, Chun-Woong
    EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2018, 117 : 279 - 289
  • [42] The effects of grid design on the performance of 3D-printed dry powder inhalers
    Ye, Yuqing
    Ma, Ying
    Fan, Ziyi
    Zhu, Jesse
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2022, 627
  • [43] Dry powder inhaler deposition in the larynx and the risk of steroid inhaler laryngitis: A computational fluid dynamics study
    Dey, Shamudra
    Bock, Jonathan M.
    Garcia, Guilherme J. M.
    JOURNAL OF AEROSOL SCIENCE, 2025, 183
  • [44] Effect of Circulation Chamber Dimensions on Aerosol Delivery Efficiency of a Commertial Dry Powder Inhaler Aerolizer®
    Sustersic, Tijana
    Vulovic, Aleksandra
    Filipovic, Nenad
    Cvijic, Sandra
    Ibric, Svetlana
    2017 IEEE 17TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2017, : 555 - 558
  • [45] Crystallization induced flower-like lactose as potential carriers for dry powder inhaler application
    Varun, Neetu
    Ghoroi, Chinmay
    POWDER TECHNOLOGY, 2022, 403
  • [46] Quality by Design in Pulmonary Drug Delivery: A Review on Dry Powder Inhaler Development, Nanotherapy Approaches, and Regulatory Considerations
    Sutar, Ashish Dilip
    Verma, Rahul Kumar
    Shukla, Rahul
    AAPS PHARMSCITECH, 2024, 25 (06):
  • [47] Nano- and Microstructured model carrier surfaces to alter dry powder inhaler performance
    Renner, Niklas
    Steckel, Hartwig
    Urbanetz, Nora
    Scherliess, Regina
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2017, 518 (1-2) : 20 - 28
  • [48] Clinical equivalence of budesonide dry powder inhaler and pressurized metered dose inhaler
    Srichana, Teerapol
    Juthong, Siwasak
    Thawithong, Ekawat
    Supaiboonpipat, Supot
    Soorapan, Suchada
    CLINICAL RESPIRATORY JOURNAL, 2016, 10 (01): : 74 - 82
  • [49] Capabilities and limitations of using powder rheology and permeability to predict dry powder inhaler performance
    Cordts, Eike
    Steckel, Hartwig
    EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2012, 82 (02) : 417 - 423
  • [50] Effect of Inhaler Design Variables on Paediatric Use of Dry Powder Inhalers
    Lexmond, Anne J.
    Kruizinga, Tonnis J.
    Hagedoorn, Paul
    Rottier, Bart L.
    Frijlink, Henderik W.
    de Boer, Anne H.
    PLOS ONE, 2014, 9 (06):