Data File Standard for Flow Cytometry, VersionFCS3.2

被引:6
|
作者
Spidlen, Josef [1 ]
Moore, Wayne [2 ]
Parks, David [3 ]
Goldberg, Michael [4 ]
Blenman, Kim [5 ]
Cavenaugh, James S.
Brinkman, Ryan [6 ,7 ,8 ]
机构
[1] BD Life Sci FlowJo, Informat, Ashland, OR USA
[2] Stanford Univ, Sch Med, Genet Dept, Stanford, CA 94305 USA
[3] Stanford Univ, Stanford Shared FACS Facil, Stanford, CA 94305 USA
[4] BD Biosci, San Jose, CA USA
[5] Yale Sch Med, New Haven, CT USA
[6] BC Canc Agcy, Terry Fox Lab, Vancouver, BC, Canada
[7] Univ British Columbia, Dept Med Genet, Vancouver, BC, Canada
[8] Cytapex Bioinformat Inc, Vancouver, BC, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
flow cytometry; FCS; 3; 2; data standard; file format; bioinformatics;
D O I
10.1002/cyto.a.24225
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
FCS 3.2 is a revision of the flow cytometry data standard based on a decade of suggested improvements from the community as well as industry needs to capture instrument conditions and measurement features more precisely. The unchanged goal of the standard is to provide a uniform file format that allows files created by one type of acquisition hardware and software to be analyzed by any other type. The standard retains the overall FCS file structure and most features of previous versions, but also contains a few changes that were required to support new types of data and use cases efficiently. These changes are incompatible with existing FCS file readers. Notably, FCS 3.2 supports mixed data types to, for example, allow FCS measurements that are intrinsically integers (e.g., indices or class assignments) or measurements that are commonly captured as integers (e.g., time ticks) to be more represented as integer values, while capturing other measurements as floating-point values in the same FCS data set. In addition, keywords explicitly specifying dyes, detectors, and analytes were added to avoid having to extract those heuristically and unreliably from measurement names. Types of measurements were formalized, several keywords added, others removed, or deprecated, and various aspects of the specification were clarified. A reference implementation of the cyclic redundancy check (CRC) calculation is provided in two programming languages since a correct CRC implementation was problematic for many vendors. (c) 2020 International Society for Advancement of Cytometry
引用
收藏
页码:100 / 102
页数:3
相关论文
共 50 条
  • [31] flowClust: a Bioconductor package for automated gating of flow cytometry data
    Lo, Kenneth
    Hahne, Florian
    Brinkman, Ryan R.
    Gottardo, Raphael
    BMC BIOINFORMATICS, 2009, 10
  • [32] The Challange of Clustering Flow Cytometry Data from Phytoplankton in Lakes
    Gluege, Stefan
    Pomati, Francesco
    Albert, Carlo
    Kauf, Peter
    Ott, Thomas
    NONLINEAR DYNAMICS OF ELECTRONIC SYSTEMS, 2014, 438 : 379 - 386
  • [33] Current trends in flow cytometry automated data analysis software
    Cheung, Melissa
    Campbell, Jonathan J.
    Whitby, Liam
    Thomas, Robert J.
    Braybrook, Julian
    Petzing, Jon
    CYTOMETRY PART A, 2021, 99 (10) : 1007 - 1021
  • [34] Scalable Analysis of Flow Cytometry Data Using R/Bioconductor
    Klinke, David J., II
    Brundage, Kathleen M.
    CYTOMETRY PART A, 2009, 75A (08) : 699 - 706
  • [35] Modeling flow cytometry data for cancer vaccine immune monitoring
    Jacob Frelinger
    Janet Ottinger
    Cécile Gouttefangeas
    Cliburn Chan
    Cancer Immunology, Immunotherapy, 2010, 59 : 1435 - 1441
  • [36] Prediction of the axillary lymph node status in mammary cancer on the basis of clinicopathological data and flow cytometry
    Mattfeldt, T
    Kestler, HA
    Sinn, HP
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2004, 42 (06) : 733 - 739
  • [37] Prediction of the axillary lymph node status in mammary cancer on the basis of clinicopathological data and flow cytometry
    T. Mattfeldt
    H. A. Kestler
    H. -P. Sinn
    Medical and Biological Engineering and Computing, 2004, 42 : 733 - 739
  • [38] FLOPTICS: A Novel Automated Gating Technique for Flow Cytometry Data
    Sriphum, Wiwat
    Wills, Gary
    Green, Nicolas G.
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON COMPLEXITY, FUTURE INFORMATION SYSTEMS AND RISK (COMPLEXIS), 2020, : 96 - 102
  • [39] Computational analysis of high-throughput flow cytometry data
    Robinson, J. Paul
    Rajwa, Bartek
    Patsekin, Valery
    Davisson, Vincent Jo
    EXPERT OPINION ON DRUG DISCOVERY, 2012, 7 (08) : 679 - 693
  • [40] Standard flow cytometry as a rapid and non-destructive proxy for cell nitrogen quota
    Martino E. Malerba
    Sean R. Connolly
    Kirsten Heimann
    Journal of Applied Phycology, 2016, 28 : 1085 - 1095