Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges

被引:100
作者
Facchinetti, Andrea [1 ]
机构
[1] Univ Padua, Dept Informat Engn, I-35131 Padua, Italy
关键词
signal processing; diabetes; calibration; model identification; filtering; prediction; ARTIFICIAL PANCREAS; BLOOD-GLUCOSE; TIME; CALIBRATION; PREDICTION; ACCURACY; IDENTIFICATION; PERFORMANCE; IMPROVEMENT; MODELS;
D O I
10.3390/s16122093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Continuous glucose monitoring (CGM) sensors are portable devices that allow measuring and visualizing the glucose concentration in real time almost continuously for several days and are provided with hypo/hyperglycemic alerts and glucose trend information. CGM sensors have revolutionized Type 1 diabetes (T1D) management, improving glucose control when used adjunctively to self-monitoring blood glucose systems. Furthermore, CGM devices have stimulated the development of applications that were impossible to create without a continuous-time glucose signal, e.g., real-time predictive alerts of hypo/hyperglycemic episodes based on the prediction of future glucose concentration, automatic basal insulin attenuation methods for hypoglycemia prevention, and the artificial pancreas. However, CGM sensors' lack of accuracy and reliability limited their usability in the clinical practice, calling upon the academic community for the development of suitable signal processing methods to improve CGM performance. The aim of this paper is to review the past and present algorithmic challenges of CGM sensors, to show how they have been tackled by our research group, and to identify the possible future ones.
引用
收藏
页数:12
相关论文
共 64 条
[21]   Model of glucose sensor error components: identification and assessment for new Dexcom G4 generation devices [J].
Facchinetti, Andrea ;
Del Favero, Simone ;
Sparacino, Giovanni ;
Cobelli, Claudio .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (12) :1259-1269
[22]   Modeling the Glucose Sensor Error [J].
Facchinetti, Andrea ;
Del Favero, Simone ;
Sparacino, Giovanni ;
Castle, Jessica R. ;
Ward, W. Kenneth ;
Cobelli, Claudio .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (03) :620-629
[23]  
Facchinetti Andrea, 2013, J Diabetes Sci Technol, V7, P1308
[24]   Real-Time Improvement of Continuous Glucose Monitoring Accuracy [J].
Facchinetti, Andrea ;
Sparacino, Giovanni ;
Guerra, Stefania ;
Luijf, Yoeri M. ;
DeVries, J. Hans ;
Mader, Julia K. ;
Ellmerer, Martin ;
Benesch, Carsten ;
Heinemann, Lutz ;
Bruttomesso, Daniela ;
Avogaro, Angelo ;
Cobelli, Claudio .
DIABETES CARE, 2013, 36 (04) :793-800
[25]   An Online Failure Detection Method of the Glucose Sensor-Insulin Pump System: Improved Overnight Safety of Type-1 Diabetic Subjects [J].
Facchinetti, Andrea ;
Del Favero, Simone ;
Sparacino, Giovanni ;
Cobelli, Claudio .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (02) :406-416
[26]   Online Denoising Method to Handle Intraindividual Variability of Signal-to-Noise Ratio in Continuous Glucose Monitoring [J].
Facchinetti, Andrea ;
Sparacino, Giovanni ;
Cobelli, Claudio .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (09) :2664-2671
[27]   An Online Self-Tunable Method to Denoise CGM Sensor Data [J].
Facchinetti, Andrea ;
Sparacino, Giovanni ;
Cobelli, Claudio .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (03) :634-641
[28]  
Feldman Ben, 2003, Diabetes Technol Ther, V5, P769, DOI 10.1089/152091503322526978
[29]  
Garcia Arturo, 2013, J Diabetes Sci Technol, V7, P1436
[30]   Evaluation of short-term predictors of glucose concentration in type 1 diabetes combining feature ranking with regression models [J].
Georga, Eleni I. ;
Protopappas, Vasilios C. ;
Polyzos, Demosthenes ;
Fotiadis, Dimitrios I. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (12) :1305-1318