Continuous Glucose Monitoring Sensors: Past, Present and Future Algorithmic Challenges

被引:94
作者
Facchinetti, Andrea [1 ]
机构
[1] Univ Padua, Dept Informat Engn, I-35131 Padua, Italy
关键词
signal processing; diabetes; calibration; model identification; filtering; prediction; ARTIFICIAL PANCREAS; BLOOD-GLUCOSE; TIME; CALIBRATION; PREDICTION; ACCURACY; IDENTIFICATION; PERFORMANCE; IMPROVEMENT; MODELS;
D O I
10.3390/s16122093
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Continuous glucose monitoring (CGM) sensors are portable devices that allow measuring and visualizing the glucose concentration in real time almost continuously for several days and are provided with hypo/hyperglycemic alerts and glucose trend information. CGM sensors have revolutionized Type 1 diabetes (T1D) management, improving glucose control when used adjunctively to self-monitoring blood glucose systems. Furthermore, CGM devices have stimulated the development of applications that were impossible to create without a continuous-time glucose signal, e.g., real-time predictive alerts of hypo/hyperglycemic episodes based on the prediction of future glucose concentration, automatic basal insulin attenuation methods for hypoglycemia prevention, and the artificial pancreas. However, CGM sensors' lack of accuracy and reliability limited their usability in the clinical practice, calling upon the academic community for the development of suitable signal processing methods to improve CGM performance. The aim of this paper is to review the past and present algorithmic challenges of CGM sensors, to show how they have been tackled by our research group, and to identify the possible future ones.
引用
收藏
页数:12
相关论文
共 64 条
[1]   From Two to One Per Day Calibration of Dexcom G4 Platinum by a Time-Varying Day-Specific Bayesian Prior [J].
Acciaroli, Giada ;
Vettoretti, Martina ;
Facchinetti, Andrea ;
Sparacino, Giovanni ;
Cobelli, Claudio .
DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 (08) :472-479
[2]  
[Anonymous], 2016, Diabetes Technol Ther, V18, P512, DOI 10.1089/dia.2016.07252.mr
[3]   The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System [J].
Bailey, Timothy ;
Bode, Bruce W. ;
Christiansen, Mark P. ;
Klaff, Leslie J. ;
Alva, Shridhara .
DIABETES TECHNOLOGY & THERAPEUTICS, 2015, 17 (11) :787-794
[4]   New Features and Performance of a Next-Generation SEVEN-Day Continuous Glucose Monitoring System with Short Lag Time [J].
Bailey, Timothy ;
Zisser, Howard ;
Chang, Anna .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (12) :749-755
[5]  
Bailey Timothy S, 2015, J Diabetes Sci Technol, V9, P209, DOI 10.1177/1932296814559746
[6]   Adaptive Calibration Algorithm for Plasma Glucose Estimation in Continuous Glucose Monitoring [J].
Barcelo-Rico, Fatima ;
Diez, Jose-Luis ;
Rossetti, Paolo ;
Vehi, Josep ;
Bondia, Jorge .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2013, 17 (03) :530-538
[7]   A Multiple Local Models Approach to Accuracy Improvement in Continuous Glucose Monitoring [J].
Barcelo-Rico, Fatima ;
Bondia, Jorge ;
Luis Diez, Jose ;
Rossetti, Paolo .
DIABETES TECHNOLOGY & THERAPEUTICS, 2012, 14 (01) :74-82
[8]  
Baysal Nihat, 2014, J Diabetes Sci Technol, V8, P1091, DOI 10.1177/1932296814553267
[9]  
Bequette B Wayne, 2014, J Diabetes Sci Technol, V8, P1204, DOI 10.1177/1932296814543661
[10]   Challenges and recent progress in the development of a closed-loop artificial pancreas [J].
Bequette, B. Wayne .
ANNUAL REVIEWS IN CONTROL, 2012, 36 (02) :255-266