Small field measurements with a novel silicon position sensitive diode array

被引:13
|
作者
Manolopoulos, S. [1 ,2 ]
Wojnecki, C. [2 ]
Hugtenburg, R. [4 ]
Sidek, M. A. Jaafar [3 ]
Chalmers, G. [2 ]
Heyes, G. [2 ]
Green, S. [2 ]
机构
[1] Sci & Technol Facil Council, Rutherford Appleton Lab, Chilton OX11 0QX, England
[2] Univ Hosp Birmingham NHS Trust, Dept Med Phys, Birmingham B15 2TH, W Midlands, England
[3] Univ Birmingham, Dept Phys & Astron, Birmingham B15 2TT, W Midlands, England
[4] Swansea Univ, Sch Med, Swansea SA2 8PP, W Glam, Wales
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2009年 / 54卷 / 03期
基金
英国科学技术设施理事会;
关键词
MICROSTRIP DOSIMETER; DELTA-OSI; PROTOTYPE;
D O I
10.1088/0031-9155/54/3/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
DOSI, a novel dosimeter based on position sensitive detectors for particle physics experiments, was used for relative clinical dosimetry measurements in small radiotherapy fields. The device is capable of dynamic measurements in real time and provides sub-millimetre spatial resolution. The basic beam data for a stereotactic radiotherapy collimator system (BrainLAB) using 6 MV photons were measured and compared with the corresponding data acquired with a small diamond detector and a PinPoint ionization chamber. All measurements showed an excellent agreement between DOSI and the diamond detector. There was an increasing discrepancy between the relative output factors (ROF) measured with DOSI and those measured with the ionization chamber with decreasing field size, specifically for collimators with a diameter smaller than 15 mm. The percentage depth doses (PDD) were in agreement to better than 1% for all depths. The agreement on off-axis ratios (OAR) was better than 3% for all collimators, whereas the agreement on relative output factors (ROF) was at the 1% level. DOSI's fast read-out electronics made it possible for all measurements to be recorded within 45 min including time to change collimators. This should reduce the overall time for commissioning and QA measurements, an important factor especially for busy radiotherapy departments.
引用
收藏
页码:485 / 495
页数:11
相关论文
共 50 条
  • [1] Novel epitaxial silicon array for small field dosimetry
    Talamonti, C.
    Zani, M.
    Menichelli, D.
    Friedl, F.
    Bisello, F.
    Bonomo, P.
    Bruzzi, M.
    Paiar, F.
    Scaringella, M.
    Bucciolini, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S416 - S417
  • [2] A silicon diode array detector for small field dosimetry with flattening filter free beams
    Biasi, G.
    Petasecca, M.
    Guatelli, S.
    Kron, T.
    Rosenfeld, A.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S919 - S920
  • [3] A silicon continuous position sensitive diode and associated electronics:: modelling and simulation
    Solal, M
    Ménard, L
    Charon, Y
    Pitre, S
    Mastrippolito, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3): : 491 - 498
  • [4] Development of a small field of view scintimammography camera based on a YAP crystal array and a position sensitive PMT
    Steinbach, D
    Majewski, S
    Williams, M
    Kross, B
    Weisenberger, AG
    Wojcik, R
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1251 - 1256
  • [5] Technical Note: Angular dependence of a 2D monolithic silicon diode array for small field dosimetry
    Stansook, Nauljun
    Utitsarn, Kananan
    Petasecca, Marco
    Newall, Matthew K.
    Duncan, Mitchell
    Nitschke, Kym
    Carolan, Martin
    Metcalfe, Peter
    Lerch, Michael L. F.
    Perevertaylo, Vladimir L.
    Tome, Wolfgang A.
    Rosenfeld, Anatoly B.
    MEDICAL PHYSICS, 2017, 44 (08) : 4313 - 4321
  • [6] POSITION RESOLUTION MEASUREMENTS FOR POSITION-SENSITIVE SILICON DETECTORS BY USE OF CIRCULAR APERTURES
    CAUSSYN, DD
    GENTRY, GL
    TOPPINS, A
    FLETCHER, NR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 286 (1-2): : 348 - 349
  • [7] Semiconductor laser diode array characterization by means of field intensity measurements
    Zeni, LG
    Cutolo, A
    Pierri, R
    TESTING, PACKAGING, RELIABILITY, AND APPLICATIONS OF SEMICONDUCTOR LASERS IV, 1999, 3626 : 167 - 175
  • [8] Micro Cantilever Movement Detection with an Amorphous Silicon Array of Position Sensitive Detectors
    Contreras, Javier
    Costa, Daniel
    Pereira, Sonia
    Fortunato, Elvira
    Martins, Rodrigo
    Wierzbicki, Rafal
    Heerlein, Holger
    Ferreira, Isabel
    SENSORS, 2010, 10 (09): : 8173 - 8184
  • [9] Color sensing ability of an amorphous silicon position sensitive detector array system
    Contreras, Javier
    Martins, Rodrigo
    Wojcik, Pawel
    Filonovich, Sergej
    Aguas, Hugo
    Gomes, Luis
    Fortunato, Elvira
    Ferreira, Isabel
    SENSORS AND ACTUATORS A-PHYSICAL, 2014, 205 : 26 - 37
  • [10] SILICON DIODE AS AN ALPHA PARTICLE DETECTOR AND SPECTROMETER FOR DIRECT FIELD MEASUREMENTS
    Oren, Unal
    Nilsson, Jonas
    Herrnsdorf, Lars
    Raaf, Christopher L.
    Mattsson, Soren
    RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) : 247 - 251