Consideration of Physiological Response in Numerical Models of Temperature During MRI of the Human Head

被引:40
作者
Wang, Zhangwei [1 ]
Lin, James C. [2 ]
Vaughan, J. Thomas [3 ]
Collins, Christopher M. [1 ]
机构
[1] Penn State Coll Med, Ctr NMR Res, Hershey, PA 17033 USA
[2] Univ Illinois, Dept Elect & Comp Engn, Chicago, IL USA
[3] Univ Minnesota, Ctr MR Res, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
model; SAR; temperature; head; physiology;
D O I
10.1002/jmri.21556
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To examine the thermal effects of the physiological response to heating during exposure to radiofrequency (RF) electromagnetic fields in magnetic resonance imaging (MRI) with a head-specific volume coil. Materials and Methods: Numerical methods were used to calculate the temperature elevation in MRI of the human head within volume coils from 64-400 MHz at different power levels both with and without consideration of temperature-induced changes in rates of metabolism, perspiration, radiation, and perfusion. Results: At the highest power levels currently allowed in MRI for head volume coils, there is little effect from the physiological response as predicted with existing methods. This study does not rule out the possibility that at higher power levels or in different types of coils (such as extremity or whole-body coils) the physiological response may have more significant effects. Conclusion: In modeling temperature increase during MRI of the human head in a head-sized volume coil at up to 3.0 W/kg head-average specific energy absorption rates, it may not be necessary to consider thermally induced changes in rates of metabolism, perfusion, perspiration, and radiation.
引用
收藏
页码:1303 / 1308
页数:6
相关论文
共 38 条
[1]   Radio frequency magnetic field mapping of a 3 tesla birdcage coil: Experimental and theoretical dependence on sample properties [J].
Alecci, M ;
Collins, CM ;
Smith, MB ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (02) :379-385
[2]  
ANGELONE LM, 2005, P 13 ANN M ISMRM MIA
[3]   Improved PML for the FDTD solution of wave-structure interaction problems [J].
Berenger, JP .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1997, 45 (03) :466-473
[4]   Specific absorption rate and temperature elevation in a subject exposed in the far-field of radio-frequency sources operating in the 10-900-MHz range [J].
Bernardi, P ;
Cavagnaro, M ;
Pisa, S ;
Piuzzi, E .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (03) :295-304
[5]  
Center for Devices and Radiologic Health, 1988, GUID SUBM PREM NOT M
[6]   Dispersion and absorption in dielectrics I. Alternating current characteristics [J].
Cole, KS ;
Cole, RH .
JOURNAL OF CHEMICAL PHYSICS, 1941, 9 (04) :341-351
[7]   Temperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz [J].
Collins, CM ;
Liu, WZ ;
Wang, JH ;
Gruetter, R ;
Vaughan, JT ;
Ugurbil, K ;
Smith, MB .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 19 (05) :650-656
[8]   Combination of optimized transmit arrays and some receive array reconstruction methods can yield homogeneous images at very high frequencies [J].
Collins, CM ;
Liu, W ;
Swift, BJ ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) :1327-1332
[9]   Signal-to-noise ratio and absorbed power as functions of main magnetic field strength, and definition of "90°" RF pulse for the head in the birdcage coil [J].
Collins, CM ;
Smith, MB .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :684-691
[10]  
Gabriel C, 1996, ALOETR19960037 AIR F