Novel Carbon/PEDOT/PSS-Based Screen-Printed Biosensors for Acetylcholine Neurotransmitter and Acetylcholinesterase Detection in Human Serum

被引:39
作者
Ashmawy, Nashwa H. [1 ]
Almehizia, Abdulrahman A. [2 ]
Youssef, Teraze A. [1 ]
Amr, Abd El-Galil E. [3 ,4 ]
Al-Omar, Mohamed A. [2 ,3 ]
Kamel, Ayman H. [1 ]
机构
[1] Ain Shams Univ, Fac Sci, Chem Dept, Cairo 11566, Egypt
[2] King Saud Univ, Coll Pharm, Pharmaceut Chem Dept, Riyadh 1451, Saudi Arabia
[3] King Saud Univ, Coll Pharm, DEDC, Pharmaceut Chem Dept, Riyadh 11451, Saudi Arabia
[4] Natl Res Ctr, Appl Organ Chem Dept, Giza 12622, Egypt
关键词
solid-contact; ISEs; PEDOT; PSS; acetylcholine; biosensors; acetylcholinesterase; POTENTIOMETRIC SENSING PLATFORM; POLYMERIC MEMBRANE SENSORS; ION-SELECTIVE ELECTRODES; MASS-SPECTROMETRY; CHOLINE; ASSAY;
D O I
10.3390/molecules24081539
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
New reliable and robust potentiometric ion-selective electrodes were fabricated using poly(3,4-ethylenedioxythiophene)/poly(styrenesulfonate) (PEDOT/PSS) as the solid contact between the sensing membrane and electrical substrate for an acetylcholine (ACh) bioassay. A film of PEDOT/PSS was deposited on a solid carbon screen-printed platform made from ceramic substrate. The selective materials used in the ion-selective electrode (ISE) sensor membrane were acetylcholinium tetraphenylborate (ACh/TPB/PEDOT/PSS-ISE) (sensor I) and triacetyl--cyclodextrin (-CD/PEDOT/PSS-ISE) (sensor II). The sensors revealed clear enhanced Nernstian response with a cationic slope 56.4 +/- 0.6 and 55.3 +/- 1.1 mV/decade toward (ACh(+)) ions over the dynamic linear range 1.0 x 10(-6)-1 x 10(-3) and 2.0 x 10(-6)-1.0 x 10(-3) M at pH 5 with limits of detection 2.0 x 10(-7) and 3.2 x 10(-7) M for sensors I and II, respectively. The selectivity behavior of both sensors was also tested and the sensors showed a significant high selectivity toward ACh(+) over different common organic and inorganic cations. The stability of the potential response for the solid-contact (SC)/ISEs was evaluated using a chronopotentiometric method and compared with that of electrodes prepared without adding the solid-contact material (PEDOT/PSS). Enhanced accuracy, excellent repeatability, good reproducibility, potential stability, and high selectivity and sensitivity were introduced by these cost-effective sensors. The sensors were also used to measure the activity of acetylcholinesterase (AChE). A linear plot between the initial rate of the hydrolysis of ACh(+) substrate and enzyme activity held 5.0 x 10(-3)-5.2 IU L-1 of AChE enzyme. Application to acetylcholine determination in human serum was done and the results were compared with the standard colorimetric method.
引用
收藏
页数:14
相关论文
共 42 条
[1]   Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion [J].
Bakker, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :L83-L85
[2]   Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers [J].
Bobacka, J .
ANALYTICAL CHEMISTRY, 1999, 71 (21) :4932-4937
[3]  
Brunton L.L., 2006, The Pharmacological Basis of Therapeutics, V11th
[4]   Poly[Ni(II) protoporphyrin IX] modified electrode for amperometric detection of acetylcholine (Ach) and choline (Ch) [J].
Carballo, Romina ;
Dall'Orto, Viviana Campo ;
Rezzano, Irene .
ANALYTICAL LETTERS, 2007, 40 (10) :1962-1971
[5]   New biomimetic sensors for the determination of tetracycline in biological samples: Batch and flow mode operations [J].
Coelho Moreira, Felismina Teixeira ;
Lara Guerreiro, Joana Rafaela ;
Azevedo, Vera Lucia ;
Kamel, Ayman H. ;
Ferreira Sales, Maria Goreti .
ANALYTICAL METHODS, 2010, 2 (12) :2039-2045
[6]   Muscarinic acetylcholine receptors and airway diseases [J].
Coulson, FR ;
Fryer, AD .
PHARMACOLOGY & THERAPEUTICS, 2003, 98 (01) :59-69
[7]   All-solid-state potentiometric sensors: A new wave for in situ aquatic research [J].
Cuartero, Maria ;
Crespo, Gaston A. .
CURRENT OPINION IN ELECTROCHEMISTRY, 2018, 10 :98-106
[8]   Critical evaluation of acetylcholine determination in rat brain microdialysates using ion-pair liquid chromatography with amperometric detection [J].
De Bundel, Dimitri ;
Sarre, Sophie ;
Van Eeckhaut, Ann ;
Smolders, Ilse ;
Michotte, Yvette .
SENSORS, 2008, 8 (08) :5171-5185
[9]   Improved method for the routine determination of acetylcholine and choline in brain microdialysate using a horseradish peroxidase column as the immobilized enzyme reactor [J].
Dong, Y ;
Wang, L ;
Shangguan, DH ;
Zhao, R ;
Liu, GQ .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 788 (01) :193-198
[10]   Detection of choline and acetylcholine in a pharmaceutical preparation using high-performance liquid chromatography/electrospray ionization mass spectrometry [J].
Dunphy, R ;
Burinsky, DJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (05) :905-915