Shock Efficacy of Subcutaneous Implantable Cardioverter-Defibrillator for Prevention of Sudden Cardiac Death Initial Multicenter Experience

被引:59
作者
Aydin, Ali [1 ]
Hartel, Friederike [1 ]
Schlueter, Michael [1 ]
Butter, Christian [3 ]
Koebe, Julia [4 ,5 ]
Seifert, Martin [3 ]
Gosau, Nils [1 ]
Hoffmann, Boris [1 ]
Hoffmann, Matthias [1 ]
Vettorazzi, Eik [6 ]
Wilke, Iris [1 ]
Wegscheider, Karl [6 ]
Reichenspurner, Hermann [2 ]
Eckardt, Lars [4 ,5 ]
Steven, Daniel [1 ]
Willems, Stephan [1 ]
机构
[1] Univ Heart Ctr, Dept Electrophysiol, Hamburg, Germany
[2] Univ Heart Ctr, Dept Cardiac Surg, Hamburg, Germany
[3] Heart Ctr Brandenburg Bernau, Dept Cardiol, Berlin, Germany
[4] Hosp Westfal Wilhelms Univ, Dept Cardiol, Div Expt & Clin Electrophysiol, Munster, Germany
[5] Hosp Westfal Wilhelms Univ, Dept Angiol, Div Expt & Clin Electrophysiol, Munster, Germany
[6] Univ Med Ctr Hamburg Eppendorf, Dept Med Biometry & Epidemiol, Ctr Med Expt, D-20246 Hamburg, Germany
关键词
implantable cardioverter-defibrillator; ventricular tachyarrhythmia; implantable cardioverter-defibrillator shock failure; defibrillation threshold; subcutaneous implantable cardioverter-defibrillator; CLINICAL-EXPERIENCE; ICD THERAPY; MANAGEMENT;
D O I
10.1161/CIRCEP.112.973339
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Recently, subcutaneous implantable cardioverter-defibrillator (S-ICD) has become available. The aim of our study was to assess the efficacy of S-ICD in a clinical setting. Methods and Results-Between June 2010 and July 2011, 40 consecutive patients (42 +/- 15 years; body mass index, 27 +/- 6 kg/m(2); left ventricular ejection fraction, 47 +/- 15%; 28 men) received an S-ICD for primary (n=17) or secondary prevention (n=23 [58%]) at 3 institutions in Germany. Intraoperative defibrillation efficacy testing failed in 1 patient with severely reduced left ventricular ejection fraction; testing was effective in all other patients. All episodes stored in the S-ICD were analyzed for appropriate and inappropriate detection, as well as effective shock delivery to convert ventricular tachyarrhythmia into sinus rhythm. During a median follow-up of 229 (interquartile range, 116-305) days, 4 patients experienced 21 episodes, with correct detection of ventricular tachyarrhythmia and subsequent shock therapy. A total of 28 shocks were delivered in these 4 patients. Mixed logistic regression modeling revealed a shock efficacy of 96.4% (95% CI, 12.8%-100%). The efficacy of first shocks, however, was only 57.9% (95% CI, 35.6%-77.4%). Four episodes were incorrectly classified as ventricular tachyarrhythmia, which led to inappropriate shock delivery in 2 patients. Conclusions-Ineffective shock delivery may occur in patients with S-ICD, even after successful intraoperative testing. Multicenter trials are required with close monitoring of safety and efficacy end points to identify patients who may be at risk for shock failure. (Circ Arrhythm Electrophysiol. 2012;5:913-919.)
引用
收藏
页码:913 / 919
页数:7
相关论文
共 18 条
[1]   Clinical experience with a novel subcutaneous implantable defibrillator system in a single center [J].
Abkenari, Lara Dabiri ;
Theuns, Dominic A. M. J. ;
Valk, Suzanne D. A. ;
Van Belle, Yves ;
de Groot, Natasja M. ;
Haitsma, David ;
Muskens-Heemskerk, Agnes ;
Szili-Torok, Tamas ;
Jordaens, Luc .
CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (09) :737-744
[2]   Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients [J].
Alter, P ;
Waldhans, S ;
Plachta, E ;
Moosdorf, R ;
Grimm, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09) :926-932
[3]   An Entirely Subcutaneous Implantable Cardioverter-Defibrillator [J].
Bardy, Gust H. ;
Smith, Warren M. ;
Hood, Margaret A. ;
Crozier, Ian G. ;
Melton, Iain C. ;
Jordaens, Luc ;
Theuns, Dominic ;
Park, Robert E. ;
Wright, David J. ;
Connelly, Derek T. ;
Fynn, Simon P. ;
Murgatroyd, Francis D. ;
Sperzel, Johannes ;
Neuzner, Joerg ;
Spitzer, Stefan G. ;
Ardashev, Andrey V. ;
Oduro, Amo ;
Boersma, Lucas ;
Maass, Alexander H. ;
Van Gelder, Isabelle C. ;
Wilde, Arthur A. ;
van Dessel, Pascal F. ;
Knops, Reinoud E. ;
Barr, Craig S. ;
Lupo, Pierpaolo ;
Cappato, Riccardo ;
Grace, Andrew A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) :36-44
[4]   Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators [J].
Brigadeau, F ;
Kouakam, C ;
Klug, D ;
Marquié, C ;
Duhamel, A ;
Mizon-Gérard, F ;
Lacroix, D ;
Kacet, S .
EUROPEAN HEART JOURNAL, 2006, 27 (06) :700-707
[5]   High defibrillation energy requirements are encountered rarely with modern dual-chamber implantable cardioverter-defibrillator systems [J].
Day, John D. ;
Olshansky, Brian ;
Moore, Stephen ;
Brown, Scott ;
Stolen, Kira Q. ;
Lerew, Darin R. .
EUROPACE, 2008, 10 (03) :345-348
[6]   Detection and management of an implantable cardioverter defibrillator lead failure - Incidence and clinical implications [J].
Ellenbogen, KA ;
Wood, MA ;
Shepard, RK ;
Clemo, HF ;
Vaughn, T ;
Holloman, K ;
Dow, M ;
Leffler, J ;
Abeyratne, A ;
Verness, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (01) :73-80
[7]   ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices) Developed in Collaboration With the American Association for Thoracic Surgery and Society of Thoracic Surgeons [J].
Epstein, Andrew E. ;
DiMarco, John P. ;
Ellenbogen, Kenneth A. ;
Estes, N. A. Mark, III ;
Freedman, Roger A. ;
Gettes, Leonard S. ;
Gillinov, A. Marc ;
Gregoratos, Gabriel ;
Hammill, Stephen C. ;
Hayes, David L. ;
Hlatky, Mark A. ;
Newby, L. Kristin ;
Page, Richard L. ;
Schoenfeld, Mark H. ;
Silka, Michael J. ;
Stevenson, Lynne Warner ;
Sweeney, Michael O. .
CIRCULATION, 2008, 117 (21) :E350-E408
[8]   Comparison of defibrillation efficacy and survival associated with right versus left pectoral placement for implantable defibrillators [J].
Gold, Michael R. ;
Shih, Hue-Teh ;
Herre, John ;
Breiter, David ;
Zhang, Yunlong ;
Schwartz, Mark .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (02) :243-246
[9]   Clinical experience of entirely subcutaneous implantable cardioverterdefibrillators in children and adults: cause for caution [J].
Jarman, Julian W. E. ;
Lascelles, Karen ;
Wong, Tom ;
Markides, Vias ;
Clague, Jonathan R. ;
Till, Janice .
EUROPEAN HEART JOURNAL, 2012, 33 (11) :1351-1359
[10]   Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of > 10 years [J].
Kleemann, Thomas ;
Becker, Torsten ;
Doenges, Klaus ;
Vater, Margit ;
Senges, Jochen ;
Schneider, Steffen ;
Saggau, Werner ;
Weisse, Udo ;
Seidl, Karlheinz .
CIRCULATION, 2007, 115 (19) :2474-2480