Background: We evaluated the body fluid (BF) module on the new Sysmex XN-1000 for counting blood cells. Methods: One hundred and eighty-seven BF samples [73 cerebrospinal fluid (CSF), 48 continuous ambulatory peritoneal dialysis (CAPD), 46 ascites, and 20 pleural fluid] were used for method comparison between the XN-1000 and manual microscopy (Fuchs-Rosenthal chamber and stained cytospin slides) for counting red blood cells (RBCs) and white blood cells (WBCs) (differential). Results: Good agreement was found for counting WBCs (y=1.06x+0.09, n=67, R-2=0.96) and mononuclear cells (MNs) (y=1.04x-0.01, n=40, R-2=0.93) in CSF. However, the XN-1000 systematically counted more polymorphonuclear cells (PMNs) (y=1.48x+0.18, n=40, R-2=0.99) compared to manual microscopy. Excellent correlation for RBCs >1x109/L (y=0.99x+116.56, n=26, R-2=0.99) in CSF was found. For other fluids (CAPD, ascites and pleural fluid) excellent agreement was found for counting WBCs (y=1.06x+0.26, n=109, R-2=0.98), MNs (y=1.06x-0.41, n=93, R-2=0.96), PMNs (y=1.06x+0.81, n=93, R-2=0.98) and RBCs (y=1.04x+110.04, n=43, R-2=0.98). By using BF XN-check, the lower limit of quantitation (LLoQ) for WBC was defined at 5x10(6)/L. Linearity was excellent for both the WBCs (R-2=0.99) and RBCs (R-2=0.99) and carry-over never exceeded 0.05%. Conclusions: The BF module on the XN-1000 is a suitable tool for fast and accurate quantification of WBC (differential) and RBC counts in CSF and other BFs in a diagnostic setting.
引用
收藏
页码:1791 / 1798
页数:8
相关论文
共 35 条
  • [31] Performance Evaluation of Body Fluid Cellular Analysis Using the Beckman Coulter UniCel DxH 800, Sysmex XN-350, and UF-5000 Automated Cellular Analyzers
    Cho, Jooyoung
    Oh, Joowon
    Lee, Sang-Guk
    Lee, You-Hee
    Song, Jaewoo
    Kim, Jeong-Ho
    ANNALS OF LABORATORY MEDICINE, 2020, 40 (02) : 122 - 131
  • [32] Mindray BC-6800 body fluid mode, performance of nucleated cells, and differential count in ascitic and pleural fluids
    Buoro, S.
    Mecca, T.
    Azzara, G.
    Seghezzi, M.
    Candiago, E.
    Gianatti, A.
    Crippa, A.
    La Gioia, A.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 (01) : 90 - 101
  • [33] On-Chip Cell Staining and Counting Platform for the Rapid Detection of Blood Cells in Cerebrospinal Fluid
    Lee, Yujin
    Kim, Byeongyeon
    Choi, Sungyoung
    SENSORS, 2018, 18 (04)
  • [34] Comparison of Sysmex XN-V body fluid mode and deep-learning-based quantification with manual techniques for total nucleated cell count and differential count for equine bronchoalveolar lavage samples
    Lapsina, Sandra
    Riond, Barbara
    Hofmann-Lehmann, Regina
    Stirn, Martina
    BMC VETERINARY RESEARCH, 2024, 20 (01)
  • [35] PHENOTYPE ANALYSIS OF UNSTIMULATED LYMPHOCYTES AND ANTI-CD3-STIMULATED PROLIFERATING T-CELLS FROM CEREBROSPINAL-FLUID AND PERIPHERAL-BLOOD IN PATIENTS WITH MULTIPLE-SCLEROSIS AND OTHER NEUROLOGICAL DISEASES
    DUFOUR, A
    SALMAGGI, A
    EOLI, M
    LAMANTIA, L
    MILANESE, C
    NESPOLO, A
    INTERNATIONAL JOURNAL OF NEUROSCIENCE, 1993, 73 (3-4) : 277 - 285