Validation of the body fluid module on the new Sysmex XN-1000 for counting blood cells in cerebrospinal fluid and other body fluids

被引:79
作者
Fleming, Cherina [1 ]
Brouwer, Rob [1 ]
Lindemans, Jan [1 ]
de Jonge, Robert [1 ]
机构
[1] Univ Med Ctr Rotterdam, Dept Clin Chem, Erasmus MC, NL-3015 CE Rotterdam, Netherlands
关键词
body fluid; cerebrospinal fluid; counting chamber; hematology analyzer; leukocytes; Sysmex XN-1000; FLOW-CYTOMETRIC ANALYSIS; AUTOMATED HEMATOLOGY; PLEURAL FLUID; MODE; ANALYZERS; XE-5000;
D O I
10.1515/cclm-2011-0927
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: We evaluated the body fluid (BF) module on the new Sysmex XN-1000 for counting blood cells. Methods: One hundred and eighty-seven BF samples [73 cerebrospinal fluid (CSF), 48 continuous ambulatory peritoneal dialysis (CAPD), 46 ascites, and 20 pleural fluid] were used for method comparison between the XN-1000 and manual microscopy (Fuchs-Rosenthal chamber and stained cytospin slides) for counting red blood cells (RBCs) and white blood cells (WBCs) (differential). Results: Good agreement was found for counting WBCs (y=1.06x+0.09, n=67, R-2=0.96) and mononuclear cells (MNs) (y=1.04x-0.01, n=40, R-2=0.93) in CSF. However, the XN-1000 systematically counted more polymorphonuclear cells (PMNs) (y=1.48x+0.18, n=40, R-2=0.99) compared to manual microscopy. Excellent correlation for RBCs >1x109/L (y=0.99x+116.56, n=26, R-2=0.99) in CSF was found. For other fluids (CAPD, ascites and pleural fluid) excellent agreement was found for counting WBCs (y=1.06x+0.26, n=109, R-2=0.98), MNs (y=1.06x-0.41, n=93, R-2=0.96), PMNs (y=1.06x+0.81, n=93, R-2=0.98) and RBCs (y=1.04x+110.04, n=43, R-2=0.98). By using BF XN-check, the lower limit of quantitation (LLoQ) for WBC was defined at 5x10(6)/L. Linearity was excellent for both the WBCs (R-2=0.99) and RBCs (R-2=0.99) and carry-over never exceeded 0.05%. Conclusions: The BF module on the XN-1000 is a suitable tool for fast and accurate quantification of WBC (differential) and RBC counts in CSF and other BFs in a diagnostic setting.
引用
收藏
页码:1791 / 1798
页数:8
相关论文
共 35 条
  • [1] Evaluation of the new body fluid mode on the Sysmex XE-5000 for counting leukocytes and erythrocytes in cerebrospinal fluid and other body fluids
    de Jonge, Robert
    Brouwer, Rob
    de Graaf, Marieke T.
    Luitwieler, Ronald L.
    Fleming, Cherina
    de Frankrijker-Merkestijn, Magda
    Smitt, Peter A. E. Sillevis
    Boonstra, Joke G.
    Lindemans, Jan
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (05) : 665 - 675
  • [2] Evaluation of Sysmex XN-1000 High-Sensitive Analysis (hsA) Research Mode for Counting and Differentiating Cells in Cerebrospinal Fluid
    Fleming, Cherina
    Russcher, Henk
    Brouwer, Rob
    Lindemans, Jan
    de Jonge, Robert
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2016, 145 (03) : 299 - 307
  • [3] UF-1000i: validation of the body fluid mode for counting cells in body fluids
    Fleming, Cherina
    Brouwer, Rob
    van Alphen, Adriaan
    Lindemans, Jan
    de Jonge, Robert
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2014, 52 (12) : 1781 - 1790
  • [4] Characterization of Candida spp. interference on the Sysmex XN-1000 body fluid mode
    Favresse, J.
    van Dievoet, M. -A.
    De Wolf, H.
    Rodriguez-Villalobos, H.
    Defour, J. -P.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (02) : E28 - E32
  • [5] Two-site evaluation of the diagnostic performance of the Sysmex XN Body Fluid (BF) module for cell count and differential in Cerebrospinal Fluid
    Buoro, S.
    Peruzzi, B.
    Fanelli, A.
    Seghezzi, M.
    Manenti, B.
    Lorubbio, M.
    Biagioli, T.
    Nannini, S.
    Ottomano, C.
    Lippi, G.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2018, 40 (01) : 26 - 33
  • [6] Cell counting chamber vs. Sysmex XN-1000 for determining white blood cell count and differentiation for body fluids
    Evren, Ebru
    Us, Ebru
    Hekimoglu, Can Huseyin
    Karahan, Zeynep Ceren
    TURKISH JOURNAL OF BIOCHEMISTRY-TURK BIYOKIMYA DERGISI, 2023, 48 (01): : 19 - 25
  • [7] Performance of the Sysmex XN-V body fluid module for canine cerebrospinal fluid cell count
    Ortiz-Nisa, Sonia
    Sanz, Alba
    Pastor, Josep
    De la Fuente, Cristian
    Anor, Sonia
    VETERINARY CLINICAL PATHOLOGY, 2021, 50 (03) : 359 - 368
  • [8] Automated Cerebrospinal Fluid Cell Counts Using the New Body Fluid Mode of Sysmex UF-1000i
    Buoro, Sabrina
    Esposito, Sara Apassiti
    Alessio, MariaGrazia
    Crippa, Alberto
    Ottomano, Cosimo
    Lippi, Giuseppe
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2016, 30 (05) : 381 - 391
  • [9] Evaluation of the Sysmex XE-5000 for automated body fluid and cerebrospinal fluid analysis
    Ho, G.
    Keutgens, A.
    Huwart, A.
    Tassin, F.
    Gothot, A.
    IMMUNO-ANALYSE & BIOLOGIE SPECIALISEE, 2011, 26 (5-6): : 256 - 263
  • [10] Canine Cerebrospinal Fluid Analysis Using Two New Automated Techniques: The Sysmex XN-V Body Fluid Mode and an Artificial-Intelligence-Based Algorithm
    Lapsina, Sandra
    Riond, Barbara
    Hofmann-Lehmann, Regina
    Stirn, Martina
    ANIMALS, 2024, 14 (11):