Management and results in periprosthetic tibial fracture after total knee arthroplasty: Two-center 15-case retrospective series at 2 years' follow-up

被引:9
作者
Bauer, Camille [1 ]
Zaharia, Bogdan [1 ]
Galliot, Florent [1 ]
Parot, Jauffrey [1 ]
Houfani, Faycal [1 ]
Mayer, Julien [2 ]
Mainard, Didier [1 ]
机构
[1] CHRU Nancy, Serv Chirurg Orthoped & Traumatol, Hop Cent, COTA, 29 Ave Marechal de Lattre de Tassigny, F-54000 Nancy, France
[2] CHR Metz Thionville, Serv Chirurg Orthoped & Traumatol, Hop Mercy, 1 Allee Chateau, F-57245 Ars Laquenexy, France
关键词
Total knee arthroplasty; Tibial fracture; Knee revision; Periprosthetic fracture; REPLACEMENT; IMPLANT; FEMUR;
D O I
10.1016/j.otsr.2020.01.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Periprosthetic tibial fracture after total knee arthroplasty (TKA) is rare, but jeopardizes implant survival. The main objective of the present study was to assess treatment efficacy, on the hypothesis that surgery provides good long-term results. Material and methods: A two-center retrospective study included 15 patients (6 male, 9 female: mean age, 71.8 +/- 10.2 years), managed between 1997 and 2017 for isolated tibial fracture after TKA. Patients were assessed clinically (IKS, inverted Oxford, Parker and SF-12 scores) and radiologically. Complications and revision surgeries were collated. Fractures were classified on the SoFCOT classification: 9 stable implants (4 type B1, 5 type C1), 4 periprosthetic osteolyses (1 type A3, 2 type B3, 1 type C3), and 2 loosenings (type A2). Treatments comprised: non-operative treatment (1 bed-ridden patient), 11 osteosyntheses for fracture on stable implant (2 standard plates, 7 locking plates, 2 intramedullary nailings), and 3 implant replacements by cemented long stem models for loosening. Results: Mean follow-up was 28 months (range, 12-120 months). Consolidation was achieved in 13 cases, at a mean 15 weeks. Complications comprised: 4 infections, 2 cases of secondary displacement, and 2 of non-union. Surgical revision was required in 8 cases, including 2 secondary implant revision procedures. Functional results were good in 10 cases. At last follow-up, mean Parker score was 7 (range, 4-8.5), Oxford score 32 (range, 16-39), and IKS score 150 (range, 85-167) with knee and function scores respectively 78 (range, 55-86) and 75 (range, 30-85). Conclusion: Radiologic and clinical results were encouraging, but with impaired quality of life and a high rate of complications. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:449 / 458
页数:10
相关论文
共 40 条
[1]   Revision Total Knee Arthroplasty for Failure of Primary Treatment of Periprosthetic Knee Fractures [J].
Abbas, Ammar M. I. ;
Morgan-Jones, Rhidian L. .
JOURNAL OF ARTHROPLASTY, 2014, 29 (10) :1996-2001
[2]  
[Anonymous], [No title captured]
[3]  
[Anonymous], [No title captured]
[4]  
[Anonymous], [No title captured]
[5]  
[Anonymous], [No title captured]
[6]  
[Anonymous], [No title captured]
[7]   Impaction bone-grafting in the treatment of a periprosthetic fracture of the tibia - A case report [J].
Beharrie, AW ;
Nelson, CL .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (04) :703-707
[8]   Questionnaire on the perceptions of patients about total knee replacement [J].
Dawson, J ;
Fitzpatrick, R ;
Murray, D ;
Carr, A .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (01) :63-69
[9]   Periprosthetic Fractures about the Knee-An Overview [J].
Della Rocca, Gregory J. .
JOURNAL OF KNEE SURGERY, 2013, 26 (01) :3-7
[10]   Biomechanical comparison of bicortical versus unicortical screw placement of proximal tibia locking plates: A cadaveric model [J].
Dougherty, Paul J. ;
Kim, Do-Gyoon ;
Meisterling, Steve ;
Wybo, Christopher ;
Yeni, Yener .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (06) :399-403