Single Transseptal Big Cryoballoon Pulmonary Vein Isolation using an Inner Lumen Mapping Catheter

被引:35
作者
Chun, K. R. Julian [1 ]
Bordignon, Stefano [1 ]
Gunawardene, Melanie [1 ]
Urban, Verena [1 ]
Kulikoglu, Mehmet [1 ]
Schulte-Hahn, Britta [1 ]
Nowak, Bernd [1 ]
Schmidt, Boris [1 ]
机构
[1] Markus Krankenhaus, Med Klin 3, Cardioangiol Ctr Bethanien, D-60431 Frankfurt, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2012年 / 35卷 / 11期
关键词
catheter ablation; atrial fibrillation; cryoballoon; PAROXYSMAL ATRIAL-FIBRILLATION; ABLATION; CONDUCTION;
D O I
10.1111/j.1540-8159.2012.03475.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The single big cryoballon technique for pulmonary vein isolation (PVI) has been limited by the need for two transseptal punctures (TP). We therefore investigated feasibility and safety of a simplified approach using a single TP and a novel circumferential mapping catheter (CMC). Methods: Patients underwent 28-mm cryoballoon PVI using a single TP. The CMC (Achieve (c) Medtronic Inc., Minneapolis, MN, USA) served as (1) guidewire and (2) as a PV mapping tool. Primary endpoint was PVI without switching to a regular guidewire. Secondary endpoints included: (1) PV signal quality during freezing, (2) time to PVI, (3) classification of successful ablation technique, (4) complications, and (5) procedural data. Results: A total of 32 patients (126 PVs) were studied (mean age: 62 +/- 11 years, 24 males, left atrium: 40 +/- 4 mm). The primary endpoint was achieved in 29/32 patients (91%) and 123/126 PVs (98%) with a procedure and fluoroscopy time of 126 +/- 26 minutes and 18.9 +/- 7.5 minutes, respectively. Real-time visualization of PVI could be observed in 61/126 (48%) PVs. Time to sustained PVI versus nonsustained PVI was 66 +/- 56 seconds versus 129 +/- 76 seconds (P < 0.001). One phrenic nerve palsy was observed. After a follow-up of 250 +/- 84 days 23/32 patients (72%) remained in sinus rhythm. Conclusion: The simplified single big cryoballoon PVI strategy appears to be safe and feasible. However, real-time PV recording was achieved in <50% of PVs. Therefore, further catheter refinements are warranted. (PACE 2012; 35:13041311)
引用
收藏
页码:1304 / 1311
页数:8
相关论文
共 50 条
  • [41] Pulmonary vein isolation with real-time pulmonary vein potential recording using second-generation cryoballoon: Procedural and biophysical predictors of acute pulmonary vein reconnection
    Wei, Hui-Qiang
    Guo, Xiao-Gang
    Zhou, Gong-Bu
    Sun, Qi
    Liu, Xu
    Yang, Jian-Du
    Luo, Bin
    Ma, Jian
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2018, 41 (01): : 14 - 21
  • [42] Clinical Experience with a Single Catheter for Mapping and Ablation of Pulmonary Vein Ostium
    De Filippo, Paolo
    He, Ding Sheng
    Brambilla, Roberta
    Gavazzi, Antonello
    Cantu, Francesco
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (04) : 367 - 373
  • [43] Evaluation of Pulmonary Vein Stenosis After Pulmonary Vein Isolation Using a Novel Circular Mapping and Ablation Catheter (PVAC)
    von Bary, Christian
    Weber, Stefan
    Dornia, Christian
    Eissnert, Christoph
    Fellner, Claudia
    Latzin, Philipp
    Fredersdorf, Sabine
    Stadler, Stefan
    Hamer, Okka W.
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (05) : 630 - 636
  • [44] Circumferential Pulmonary Vein Isolation with the Cryoballoon Technique
    Cale, Rita
    Cavaco, Diogo
    Adragao, Pedro
    Vieira, Antonio Pinheiro
    Almeida, Sofia
    Dionisio, Teresa
    Roque, Carla
    Bernardo, Ricardo
    Scanavacca, Mauricio
    Santos, Katya Reis
    Morgado, Francisco
    Silva, Jose Aniceto
    [J]. REVISTA PORTUGUESA DE CARDIOLOGIA, 2010, 29 (06) : 1055 - 1058
  • [45] A frozen decade: 10 years outcome after cryoballoon pulmonary vein isolation
    Rottner, Laura
    Metzner, Andreas
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (07) : 1391 - 1393
  • [46] Single-Catheter Technique for Pulmonary Vein Antrum Isolation: Is It Sufficient to Identify and Close the Residual Gaps Without a Circular Mapping Catheter?
    Dong, Jianzeng
    Liu, Xingpeng
    Long, Deyong
    Yu, Ronghui
    Tang, Ribo
    Lue, Fei
    Ma, Changsheng
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (03) : 273 - 279
  • [47] Procedural characteristics of pulmonary vein isolation using the novel third-generation cryoballoon
    Fuernkranz, Alexander
    Bologna, Fabrizio
    Bordignon, Stefano
    Perrotta, Laura
    Dugo, Daniela
    Schmidt, Boris
    Chun, Julian K. R.
    [J]. EUROPACE, 2016, 18 (12): : 1795 - 1800
  • [48] Evaluation of cryoballoon pulmonary vein isolation lesions during the acute and chronic phases using a high-resolution mapping system
    Sekihara, Takayuki
    Miyazaki, Shinsuke
    Aoyama, Daisetsu
    Nagao, Moeko
    Tsuji, Toshihiko
    Kakehashi, Shota
    Mukai, Moe
    Eguchi, Tomoya
    Hasegawa, Kanae
    Uzui, Hiroyasu
    Tada, Hiroshi
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2022, 65 (01) : 123 - 131
  • [49] Long Term Follow-up of Pulmonary Vein Isolation Using Cryoballoon Ablation
    Davies, Allan J.
    Jackson, Nick
    Barlow, Malcolm
    Leitch, James
    [J]. HEART LUNG AND CIRCULATION, 2016, 25 (03) : 290 - 295
  • [50] Straight and crosier-shaped catheter techniques for phrenic nerve stimulation during cryoballoon pulmonary vein isolation for the treatment of atrial fibrillation
    Kaczmarek, Krzysztof
    Zuchowski, Bartosz
    Cygankiewicz, Iwona
    Krakowiak, Anna
    Wranicz, Jerzy Krzysztof
    Wykretowicz, Andrzej
    Ptaszynski, Pawel
    [J]. KARDIOLOGIA POLSKA, 2019, 77 (09) : 868 - 874