Single Transseptal Big Cryoballoon Pulmonary Vein Isolation using an Inner Lumen Mapping Catheter

被引:35
作者
Chun, K. R. Julian [1 ]
Bordignon, Stefano [1 ]
Gunawardene, Melanie [1 ]
Urban, Verena [1 ]
Kulikoglu, Mehmet [1 ]
Schulte-Hahn, Britta [1 ]
Nowak, Bernd [1 ]
Schmidt, Boris [1 ]
机构
[1] Markus Krankenhaus, Med Klin 3, Cardioangiol Ctr Bethanien, D-60431 Frankfurt, Germany
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2012年 / 35卷 / 11期
关键词
catheter ablation; atrial fibrillation; cryoballoon; PAROXYSMAL ATRIAL-FIBRILLATION; ABLATION; CONDUCTION;
D O I
10.1111/j.1540-8159.2012.03475.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The single big cryoballon technique for pulmonary vein isolation (PVI) has been limited by the need for two transseptal punctures (TP). We therefore investigated feasibility and safety of a simplified approach using a single TP and a novel circumferential mapping catheter (CMC). Methods: Patients underwent 28-mm cryoballoon PVI using a single TP. The CMC (Achieve (c) Medtronic Inc., Minneapolis, MN, USA) served as (1) guidewire and (2) as a PV mapping tool. Primary endpoint was PVI without switching to a regular guidewire. Secondary endpoints included: (1) PV signal quality during freezing, (2) time to PVI, (3) classification of successful ablation technique, (4) complications, and (5) procedural data. Results: A total of 32 patients (126 PVs) were studied (mean age: 62 +/- 11 years, 24 males, left atrium: 40 +/- 4 mm). The primary endpoint was achieved in 29/32 patients (91%) and 123/126 PVs (98%) with a procedure and fluoroscopy time of 126 +/- 26 minutes and 18.9 +/- 7.5 minutes, respectively. Real-time visualization of PVI could be observed in 61/126 (48%) PVs. Time to sustained PVI versus nonsustained PVI was 66 +/- 56 seconds versus 129 +/- 76 seconds (P < 0.001). One phrenic nerve palsy was observed. After a follow-up of 250 +/- 84 days 23/32 patients (72%) remained in sinus rhythm. Conclusion: The simplified single big cryoballoon PVI strategy appears to be safe and feasible. However, real-time PV recording was achieved in <50% of PVs. Therefore, further catheter refinements are warranted. (PACE 2012; 35:13041311)
引用
收藏
页码:1304 / 1311
页数:8
相关论文
共 50 条
  • [31] Comparison of effects on coagulation and inflammatory markers using a duty-cycled bipolar and unipolar radiofrequency pulmonary vein ablation catheter vs. a cryoballoon catheter for pulmonary vein isolation
    Malmborg, Helena
    Christersson, Christina
    Lonnerholm, Stefan
    Blomstrom-Lundqvist, Carina
    EUROPACE, 2013, 15 (06): : 798 - 804
  • [32] Successful Transseptal Puncture and Cryoballoon Pulmonary Vein Isolation in Adverse Anatomy Interrupted Inferior Caval Vein and Azygos Continuation
    Metzner, Andreas
    Chun, K. R. Julian
    Kivelitz, D.
    Kuck, Karl-Heinz
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (05) : E24 - E27
  • [33] Initial results of using a novel irrigated multielectrode mapping and ablation catheter for pulmonary vein isolation
    Shin, Dong-In
    Kirmanoglou, Kiriakos
    Eickholt, Christian
    Schmidt, Jan
    Clasen, Lukas
    Butzbach, Britta
    Rassaf, Tienush
    Merx, Marc
    Kelm, Malte
    Meyer, Christian
    HEART RHYTHM, 2014, 11 (03) : 375 - 383
  • [34] Improved Procedural Efficacy of Pulmonary Vein Isolation Using the Novel Second-Generation Cryoballoon
    Fuernkranz, Alexander
    Bordignon, Stefano
    Schmidt, Boris
    Gunawardene, Melanie
    Schulte-Hahn, Britta
    Urban, Verena
    Bode, Frank
    Nowak, Bernd
    Chun, Julian K. R.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (05) : 492 - 497
  • [35] Postmortem late phase histopathology after pulmonary vein isolation using a cryoballoon: A case report
    Ukita, Kohei
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Yasumoto, Koji
    Yasumura, Keisuke
    Tanaka, Akihiro
    Matsunaga-Lee, Yasuharu
    Nakamura, Daisuke
    Yano, Masamichi
    Yamato, Masaki
    Egami, Yasuyuki
    Shutta, Ryu
    Nishino, Masami
    Tanouchi, Jun
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (07): : 1066 - 1068
  • [36] Individualized cryoballoon energy pulmonary vein isolation guided by real-time pulmonary vein recordings, the randomized ICE-Ttrial
    Chun, K. R. Julian
    Stich, Marie
    Fuernkranz, Alexander
    Bordignon, Stefano
    Perrotta, Laura
    Dugo, Daniela
    Bologna, Fabrizio
    Schmidt, Boris
    HEART RHYTHM, 2017, 14 (04) : 495 - 500
  • [37] Electroanatomical mapping improves procedural outcomes of cryoballoon pulmonary vein isolation (the Achieve Plus study)
    De Greef, Yves
    Tijskens, M.
    De Torres, J. P. Abugattas
    Sofianos, D.
    Cecchini, F.
    De Schouwer, K.
    De Cocker, J.
    Buysschaert, I.
    Varnavas, V.
    Wolf, M.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (04) : 923 - 930
  • [38] Autonomic nervous system modulation and clinical outcome after pulmonary vein isolation using the second-generation cryoballoon
    Miyazaki, Shinsuke
    Nakamura, Hiroaki
    Taniguchi, Hiroshi
    Hachiya, Hitoshi
    Kajiyama, Takatsugu
    Watanabe, Tomonori
    Igarashi, Miyako
    Ichijo, Sadamitsu
    Hirao, Kenzo
    Iesaka, Yoshito
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (09) : 1015 - 1020
  • [39] High rate of persistent iatrogenic atrial septal defect after single transseptal puncture for cryoballoon pulmonary vein isolation
    Linhart, Markus
    Werner, Jessica T.
    Stoeckigt, Florian
    Kohlmann, Annika T.
    Lodde, Pia C.
    Linneborn, Lutz P. T.
    Beiert, Thomas
    Hammerstingl, Christoph
    Borras, Roger
    Nickenig, Georg
    Andrie, Rene P.
    Schrickel, Jan W.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 52 (02) : 141 - 148
  • [40] The Permanency of Pulmonary Vein Isolation Using a Balloon Cryoablation Catheter
    Ahmed, Humera
    Neuzil, Petr
    Skoda, Jan
    D'Avila, Andre
    Donaldson, David M.
    Laragy, Margaret C.
    Reddy, Vivek Y.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (07) : 731 - 737