Combined treatment of highly contaminated winery wastewater

被引:38
作者
Kirzhner, F. [1 ]
Zimmels, Y. [1 ]
Shraiber, Y. [2 ]
机构
[1] Technion Israel Inst Technol, Dept Civil & Environm Engn, IL-32000 Haifa, Israel
[2] Keren Kayemeth Lelsrael, Dept Engn, IL-26103 Kiriat Haim, Israel
关键词
electrocoagulation; winery wastewater; aquatic plants; BOD; COD; removal; economic aspects;
D O I
10.1016/j.seppur.2008.03.034
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In recent years, electrocoagulation (EC) has received increasing attention concerning its potential for destruction and removal of organic and non-organic pollutants in wastewater. The objective of the Current study was to examine the potential of EC, to treat different winery wastewaters (WWW), which are characterized by heavy loads of organic pollutants. To this end EC of WWW was conducted at 2 A, and applied voltage up to 10V. Laboratory tests of raw WWW treatment in different application periods (from 10 to 40 min) of EC were carried out, and the removal efficiency was studied. The potential of EC to improve the water quality of raw WWW, prior to further processing, was demonstrated. Enhanced removal of the WWW pollutants was found at longer treatment periods. A 10 min batch treatment of WWW produced 16.4-27.9% reduction of the biochemical oxygen demand (BOD), 28.2-41.9% of the chemical oxygen demand (COD), and 89.2% the total phosphorus. In view of the high organic load of the WWW, this involved removal of thousands mg L-1 COD. This facilitates further treatment by aquatic plants. At 1:1, W:F dilution, 97.5 and 95.6% of the BOD were removed, after 23 days of treatment, with the floating Hydrocotyle umbellate and Eichhornia crassipes plants and aeration, respectively, as compared to 28.5% in the control. Emergent plants (salt marshes with rushes) proved to be exceptionally effective in removing 99.2% of the BOD and 98.2% of the COD. These plants performed well at the high organic loads of the WWW. A scheme for a two-stage treatment of raw WWW is described. In the first stage WWW is treated by EC and its effluent with reduced organic load is then purified in the second stage, comprising aquatic plants. Finally economic aspects of the proposed system are outlined. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:38 / 44
页数:7
相关论文
共 23 条
  • [1] *AM PUBL HLTH ASS, 1995, STAND METH EX WAT EA
  • [2] Balasubramanian N, 2001, CHEM ENG TECHNOL, V24, P519, DOI 10.1002/1521-4125(200105)24:5<519::AID-CEAT519>3.0.CO
  • [3] 2-P
  • [4] Electrochemical treatment applied to food-processing industrial wastewater
    Barrera-Díaz, C
    Roa-Morales, G
    Avila-Córdoba, L
    Pavón-Silva, T
    Bilyeu, B
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (01) : 34 - 38
  • [5] BENSALAH N, 2006, CHEM TECHNOL INDIAN, V1, P2
  • [6] Treatment of the textile wastewater by combined electrocoagulation
    Can, OT
    Kobya, M
    Demirbas, E
    Bayramoglu, M
    [J]. CHEMOSPHERE, 2006, 62 (02) : 181 - 187
  • [7] Electrocoagulation and electroflotation of restaurant wastewater
    Chen, GH
    Chen, XM
    Yue, PL
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING, 2000, 126 (09) : 858 - 863
  • [8] Separation of pollutants from restaurant wastewater by electrocoagulation
    Chen, XM
    Chen, GH
    Yue, PL
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2000, 19 (1-2) : 65 - 76
  • [9] COSSU R, 2001, ECOL ENG, V16
  • [10] Anaerobic digestion of winery wastewaters derived from different wine making processes
    Daffonchio, D
    Colombo, M
    Origgi, G
    Sorlini, C
    Andreoni, V
    [J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 1998, 33 (08): : 1753 - 1770