Contrast-enhanced, ultrafast 3D pulmonary MR angiography in a single breath-hold: Initial assessment of imaging performance

被引:59
|
作者
Steiner, P [1 ]
McKinnon, GC [1 ]
Romanowski, B [1 ]
Goehde, SC [1 ]
Hany, T [1 ]
Debatin, JF [1 ]
机构
[1] UNIV ZURICH HOSP, DEPT RADIOL, CH-8091 ZURICH, SWITZERLAND
关键词
magnetic resonance (MR); three-dimensional; pulmonary arteries; MR; vascular studies; magnetic resonance (MR) rapid imaging; VASCULATURE; EXPERIENCE; STRATEGIES; EMBOLISM; FLOW;
D O I
10.1002/jmri.1880070127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An ultrafast three-dimensional (3D) sequence was developed, enabling the acquisition of 44 contiguous 2.0- to 2.2-mm thin sections, during intravenous application of paramagnetic contrast, in a single breath-hold. To estimate the potential clinical usefulness, images were assessed qualitatively and quantitatively with regard to visibility of main, lobar, segmental, and subsegmental pulmonary arteries. Five volunteers were examined using a 192 x 192 matrix with an imaging time of 23 seconds and five other volunteers with a 160 x 160 matrix (18 seconds). Each volunteer was imaged in apnea and during shallow respiration. The breath-held 23-second scans revealed excellent image quality and near complete visualization of central and segmental, as well as 81% of subsegmental, pulmonary arteries. Imaging time can be shortened to 18 seconds with only marginal loss in visualization performance (P < .05). Respiratory motion was found to cause significant worsening of image quality and vessel detectability. To maintain relevance in a clinical setting, imaging time can be minimized at the cost of a reduction in spatial resolution.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [31] Takayasu arteritis: Diagnosis with breath-hold contrast-enhanced three-dimensional MR angiography
    Yamada, I
    Nakagawa, T
    Himeno, Y
    Kobayashi, Y
    Numano, F
    Shibuya, H
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 11 (05): : 481 - 487
  • [32] Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography
    Kopka, L
    Vosshenrich, R
    Rodenwaldt, J
    Grabbe, E
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 345 - 348
  • [33] Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries
    Tan, Huan
    Koktzoglou, Ioannis
    Glielmi, Christopher
    Galizia, Mauricio
    Edelman, Robert R.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2012, 14
  • [34] Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries
    Huan Tan
    Ioannis Koktzoglou
    Christopher Glielmi
    Mauricio Galizia
    Robert R Edelman
    Journal of Cardiovascular Magnetic Resonance, 14
  • [35] Motion matched K-space sampling for breath-hold contrast enhanced 3D coronary MR angiography
    Wang, Y
    Lee, HM
    Winchester, PA
    Yang, Z
    Bergman, G
    Shaknovich, A
    RADIOLOGY, 1998, 209P : 355 - 355
  • [36] Influence of an automatic MR power injector with different injection rates on contrast-enhanced breath-hold 3D MR angiography of the abdominal aorta and its branches
    Kopka, L
    Castillo, E
    Rodenwaldt, J
    Grabbe, EH
    RADIOLOGY, 1997, 205 : 157 - 157
  • [37] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [38] Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: Time-resolved imaging versus single-phase imaging
    Van Hoe, L
    De Jaegere, T
    Bosmans, H
    Stockx, L
    Vanbeckevoort, D
    Oyen, R
    Fagard, R
    Marchal, G
    RADIOLOGY, 2000, 214 (01) : 149 - 156
  • [39] Time-resolved visualization of the coronary arteries with contrast-enhanced, 3D undersampled projection reconstruction (PR) MR angiography in a single breath-hold using an intravascular contrast agent
    Barger, AV
    Hany, TF
    Block, WF
    Mistretta, CA
    Grist, TM
    RADIOLOGY, 2000, 217 : 285 - 285
  • [40] Time-resolved visualization of the coronary arteries with contrast-enhanced, 3D undersampled projection reconstruction (PR) MR angiography in a single breath-hold using an intravascular contrast agent
    Hany, TF
    Barger, AV
    Mistretta, CA
    Grist, TM
    CIRCULATION, 2000, 102 (18) : 399 - 399