Contrast-enhanced, ultrafast 3D pulmonary MR angiography in a single breath-hold: Initial assessment of imaging performance

被引:59
作者
Steiner, P [1 ]
McKinnon, GC [1 ]
Romanowski, B [1 ]
Goehde, SC [1 ]
Hany, T [1 ]
Debatin, JF [1 ]
机构
[1] UNIV ZURICH HOSP, DEPT RADIOL, CH-8091 ZURICH, SWITZERLAND
关键词
magnetic resonance (MR); three-dimensional; pulmonary arteries; MR; vascular studies; magnetic resonance (MR) rapid imaging; VASCULATURE; EXPERIENCE; STRATEGIES; EMBOLISM; FLOW;
D O I
10.1002/jmri.1880070127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An ultrafast three-dimensional (3D) sequence was developed, enabling the acquisition of 44 contiguous 2.0- to 2.2-mm thin sections, during intravenous application of paramagnetic contrast, in a single breath-hold. To estimate the potential clinical usefulness, images were assessed qualitatively and quantitatively with regard to visibility of main, lobar, segmental, and subsegmental pulmonary arteries. Five volunteers were examined using a 192 x 192 matrix with an imaging time of 23 seconds and five other volunteers with a 160 x 160 matrix (18 seconds). Each volunteer was imaged in apnea and during shallow respiration. The breath-held 23-second scans revealed excellent image quality and near complete visualization of central and segmental, as well as 81% of subsegmental, pulmonary arteries. Imaging time can be shortened to 18 seconds with only marginal loss in visualization performance (P < .05). Respiratory motion was found to cause significant worsening of image quality and vessel detectability. To maintain relevance in a clinical setting, imaging time can be minimized at the cost of a reduction in spatial resolution.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 31 条
  • [1] CLINICAL FEATURES OF SUBMASSIVE AND MASSIVE PULMONARY EMBOLI
    BELL, WR
    SIMON, TL
    DEMETS, DL
    [J]. AMERICAN JOURNAL OF MEDICINE, 1977, 62 (03) : 355 - 360
  • [2] ECHOCARDIOGRAPHIC EVALUATION OF PULMONARY-EMBOLISM AND ITS RESPONSE TO THERAPEUTIC INTERVENTIONS
    COME, PC
    [J]. CHEST, 1992, 101 (04) : S151 - S162
  • [3] Human aorta: Preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets
    Davis, CP
    Ladd, ME
    Romanowski, BJ
    Wildermuth, S
    Knoplioch, JF
    Debatin, JF
    [J]. RADIOLOGY, 1996, 199 (01) : 37 - 40
  • [4] FOO TK, 1996, SOC MAGNETIC RESONAN, P453
  • [5] SINGLE-BREATH-HOLD VENOUS OR ARTERIAL FLOW SUPPRESSED PULMONARY VASCULAR MR-IMAGING WITH PHASED-ARRAY COILS
    FOO, TKF
    MACFALL, JR
    SOSTMAN, HD
    HAYES, CE
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (04): : 611 - 616
  • [6] CARDIAC-GATED MR-ANGIOGRAPHY OF PULSATILE FLOW - K-SPACE STRATEGIES
    FRANCK, A
    SELBY, K
    VANTYEN, R
    NORDELL, B
    SALONER, D
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (03): : 297 - 307
  • [7] GEFTER WB, 1993, J THORAC IMAG, V7, P208
  • [8] DETECTION OF PULMONARY-EMBOLISM IN PATIENTS WITH UNRESOLVED CLINICAL AND SCINTIGRAPHIC DIAGNOSIS - HELICAL CT VERSUS ANGIOGRAPHY
    GOODMAN, LR
    CURTIN, JJ
    MEWISSEN, MW
    FOLEY, WD
    LIPCHIK, RJ
    CRAIN, MR
    SAGAR, KB
    COLLIER, BD
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 164 (06) : 1369 - 1374
  • [9] PULMONARY ANGIOGRAPHY WITH MR-IMAGING - PRELIMINARY CLINICAL-EXPERIENCE
    GRIST, TM
    SOSTMAN, HD
    MACFALL, JR
    FOO, TK
    SPRITZER, CE
    WITTY, L
    NEWMAN, GE
    DEBATIN, JF
    TAPSON, V
    SALTZMAN, HA
    [J]. RADIOLOGY, 1993, 189 (02) : 523 - 530
  • [10] GRIST TM, 1996, SOC MAGNETIC RESONAN, P163