A Fast Full-line Tripping Distance Protection Method for HVDC Transmission Line

被引:0
|
作者
Zhang, Jiankang [1 ]
Suonan, Jiale [1 ]
Jiao, Zaibin [1 ]
Song, Guobing [1 ]
Su, Xiaohua [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
[2] Northwest China Grid Co Ltd, Xian, Peoples R China
基金
中国国家自然科学基金;
关键词
HVDC transmission line; distance protection; distributed parameter model; RL model; primary protection;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Though distance protection has been successfully used for AC transmission line, there is no practical application of it for HVDC transmission line. For distance protection, it is essential to measure accurately at the zone boundary to distinguish internal fault from external correctly, and high measurement accuracy at any part of the full line is unnecessary. Besides, HVDC transmission line is generally connected with smoothing reactor at two ends and it can be regarded as the operating boundary of distance protection. Considering these features, a fast full-line tripping distance protection method for HVDC transmission line is introduced in this paper. Based on distributed parameter model, the voltage and current at the end-point are calculated accurately using those at the relay point. After that, the line between the end-point and fault point is simplified as lumped parameter RL model and the fault distance is obtained with differential equations. In this way, high calculation accuracy at the zone boundary is attained and which contributes greatly to the improvement of protection performance. Simulation results show that this method is capable of protecting the whole line with high rapidity, and can be used as primary protection for HVDC transmission.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] An Efficient Method of Automatic Distance Relay Settings for Transmission Line Protection
    Penthong, Thanakorn
    Hongesombut, Komsan
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [22] A fast boundary protection for an AC transmission line connected to an LCC-HVDC inverter station
    Zhen Liu
    Houlei Gao
    Sibei Luo
    Le Zhao
    Yuyao Feng
    Protection and Control of Modern Power Systems, 2020, 5
  • [23] A fast boundary protection for an AC transmission line connected to an LCC-HVDC inverter station
    Liu, Zhen
    Gao, Houlei
    Luo, Sibei
    Zhao, Le
    Feng, Yuyao
    PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2020, 5 (01)
  • [24] Improved Protection Method of HVDC Transmission Line Based on the Analysis of Traveling Wave Dispersion
    Xie, L. H.
    Jin, L. J.
    Wang, X. L.
    Ning, L. H.
    Wang, T. L.
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014,
  • [25] Research on Extension Method of Polar Wave Change Rate Protection for HVDC Transmission Line
    Zhen, Yongzan
    Su, Ningsai
    Yang, Jingyi
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (15): : 5212 - 5220
  • [26] Configuration Scheme of Transmission Line Protection for Flexible HVDC Grid
    Dong X.
    Tang L.
    Shi S.
    Qiu Y.
    Kong M.
    Pang H.
    Dianwang Jishu/Power System Technology, 2018, 42 (06): : 1752 - 1759
  • [27] A Transient Harmonic Current Protection Scheme for HVDC Transmission Line
    Zheng Xiao-Dong
    Tai Neng-Ling
    Thorp, James S.
    Yang Guang-Liang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (04) : 2278 - 2285
  • [28] Analyzing the Welfare Impacts of Full-line Forcing Contracts
    Ho, Justin
    Ho, Katherine
    Mortimer, Julie Holland
    JOURNAL OF INDUSTRIAL ECONOMICS, 2012, 60 (03): : 468 - 498
  • [29] Discussion on configuration scheme of remote tripping protection in 750 kV transmission line
    Northwest Electric Power Dispatching and Communication Center, Xi'an 710048, China
    Dianli Xitong Zidonghue, 2008, 12 (94-96):
  • [30] A novel method for adaptive distance protection of transmission line connected to wind farms
    Sadeghi, Hadi
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 43 (01) : 1376 - 1382