Effect of column dimension on observed column efficiency in very high pressure liquid chromatography

被引:31
作者
Wu, Naijun [1 ]
Bradley, Ashley C. [2 ]
机构
[1] Merck & Co Inc, Rahway, NJ 07065 USA
[2] N Carolina Agr & Tech State Univ, Dept Chem, Greensboro, NC USA
关键词
Extra-column volume; Band-broadening; Column dimension; Sub-2 mu m particles; Ultra-high pressure liquid chromatography; UPLC; SUB-2-MU-M POROUS PARTICLES; FAST SEPARATIONS; DIFFUSION-COEFFICIENTS; PRACTICAL ASPECTS; MASS-TRANSFER; PERFORMANCE; TEMPERATURE; DISPERSION; DISSIPATION; SYSTEMS;
D O I
10.1016/j.chroma.2012.05.054
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The effect of extra-column volume on observed linear velocity was investigated for columns of various internal diameters in very high pressure liquid chromatography. The results showed that the observed linear velocities were approximately 4.5, 9.5, 16.8. and 39.5% lower than the linear velocities corrected for the extra-column volume contribution for 4.6,3.0,2.1, and 1.0 mm internal diameter columns, respectively. An empirical relationship between extra-column band broadening and extra-column volume was obtained using 50 cm long tubings of various internal diameters. The peak variance from the extra-column volume is near linearly proportional to the square of the extra-column volume for tubings with 0.0635-0.178 mm (0.025-0.07 in.) i.d. using a 50/50 acetonitrile/water mobile phase at flow rates greater than 0.3 mL/min. The effect of column internal diameter and column length on observed efficiency was studied using 50 mm columns with four different column internal diameters and 2.1 mm i.d columns with three different lengths. The results showed that the observed column efficiencies for 3.0, 2.1, and 1.0 mm internal diameter columns were 18, 33, and 73% lower than that for a 4.6 mm internal diameter column for benzophenone (k = 5.5), respectively. An approximate 20% decrease in theoretical plate number was observed for propiophenone (k = 3.3) using a 50 mm x 2.1 mm column packed with 1.7 mu m particles compared to a 150 mm x 2.1 mm column packed with 5.0 mu m particles, while the former column provided 9 fold faster separation. It is the column to extra column volume ratio instead of absolute extra-column volume that determines the degree of extra-column band-broadening in VHPLC. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:113 / 120
页数:8
相关论文
共 40 条
[11]   Influence of the errors made in the measurement of the extra-column volume on the accuracies of estimates of the column efficiency and the mass transfer kinetics parameters [J].
Gritti, Fabrice ;
Felinger, Attila ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1136 (01) :57-72
[12]   The current revolution in column technology: How it began, where is it going? [J].
Gritti, Fabrice ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1228 :2-19
[13]   Influence of Viscous Friction Heating on the Efficiency of Columns Operated under Very High Pressures [J].
Gritti, Fabrice ;
Martin, Michel ;
Guiochon, Georges .
ANALYTICAL CHEMISTRY, 2009, 81 (09) :3365-3384
[14]   Method transfer for fast liquid chromatography in pharmaceutical analysis: Application to short columns packed with small particle. Part I: Isocratic separation [J].
Guillarme, Davy ;
Nguyen, Dao T. -T. ;
Rudaz, Serge ;
Veuthey, Jean-Luc .
EUROPEAN JOURNAL OF PHARMACEUTICS AND BIOPHARMACEUTICS, 2007, 66 (03) :475-482
[15]   ULTIMATE LIMITS IN HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
HALASZ, I ;
ENDELE, R ;
ASSHAUER, J .
JOURNAL OF CHROMATOGRAPHY, 1975, 112 (OCT29) :37-60
[16]   SAMPLING AND EXTRA-COLUMN EFFECTS IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - INFLUENCE OF PEAK SKEW ON PLATE COUNT CALCULATIONS [J].
KIRKLAND, JJ ;
YAU, WW ;
STOKLOSA, HJ ;
DILKS, CH .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1977, 15 (08) :303-316
[17]  
KREJCI M., 1992, TRACE ANAL MICROCOLU, P35
[18]   Evaluation of 1.0 mm i.d. column performances on ultra high pressure liquid chromatography instrumentation [J].
Lestremau, Francois ;
Wu, Di ;
Szucs, Roman .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (30) :4925-4933
[19]   Accuracy of empirical correlations for estimating diffusion coefficients in aqueous organic mixtures [J].
Li, JW ;
Carr, PW .
ANALYTICAL CHEMISTRY, 1997, 69 (13) :2530-2536
[20]   VISCOUS DISSIPATION IN PACKED-BEDS [J].
LIN, HJ ;
HORVATH, S .
CHEMICAL ENGINEERING SCIENCE, 1981, 36 (01) :47-55