Sensitive, rapid and quantitative detection of substance P in serum samples using an integrated microfluidic immunochip

被引:18
|
作者
Horak, Josef [1 ]
Dincer, Can [1 ]
Bakirci, Hueseyin [1 ]
Urban, Gerald [1 ]
机构
[1] Univ Freiburg, Dept Microsyst Engn, Lab Sensors, D-79110 Freiburg, Germany
关键词
Biochip; Immunoassay; Microfluidics; Electrochemical detection; Substance P; PLASMA; NEUROPEPTIDES; PHOTORESIST; SALIVA; LIMITS; POINT;
D O I
10.1016/j.bios.2014.02.058
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Miniaturized diagnostic devices hold the promise of accelerate the specific and sensitive detection of various biomarkers, which can translate into many areas of medicine - from cheaper clinical trials, to early diagnosis and treatment of complex diseases. Therefore, we report on a disposable integrated chip-based capillary immunoassay featuring a microfluidic ELISA format combining electrochemical detection and low-cost fabrication employing a dry film photoresist, Vacrel (R) 8100. The readily accessible carboxylate groups on the material surface allow fast and high yield immobilization of biomolecules using amine-specific coupling via reactive esters requiring no laborious surface pretreatment. The integrated microfluidic system provides a convenient platform for a flow-through immunoassay. Capillary force is used for easy reagent delivery and loading the chip channel. We performed rapid quantification of serum level of substance P, a potential biomarker of acute neuroinflammation, using the developed microfluidic immunochip. Our miniaturized assay demonstrated a sensitive electrochemical detection of the antigen at 15.4 pg ml(-1) (11.5 pM) using only 5 mu l of the biological fluid while cutting the total assay preparation time in half and the read-out time to 10 min. Combining microfluidics and fabrication suitable for mass production with the capability of testing clinically relevant samples creates conditions for the construction of low-cost and portable point of care diagnostic devices with minimal auxiliary electronics. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 192
页数:7
相关论文
共 50 条
  • [1] An integrated device for the rapid and sensitive detection of the influenza hemagglutinin
    Anderson, Caitlin E.
    Buser, Joshua R.
    Fleming, Alexis M.
    Strauch, Eva-Maria
    Ladd, Paula D.
    Englund, Janet
    Baker, David
    Yager, Paul
    LAB ON A CHIP, 2019, 19 (05) : 885 - 896
  • [2] Highly Sensitive and Rapid Assay of Substance P and Streptolysin O in Human Serum Using Immuno-liposomes and Gramicidin Channels
    Sakamoto, Misato
    Shoji, Atsushi
    Sugawara, Masao
    ANALYTICAL SCIENCES, 2013, 29 (09) : 877 - 883
  • [3] An integrated microfluidic platform for rapid detection and subtyping of influenza viruses from clinical samples
    Chien-Hsuan Tai
    Yi-Che Tsai
    Chih-Hung Wang
    Tzong-Shiann Ho
    Chih-Peng Chang
    Gwo-Bin Lee
    Microfluidics and Nanofluidics, 2014, 16 : 501 - 512
  • [4] An integrated microfluidic platform for rapid detection and subtyping of influenza viruses from clinical samples
    Tai, Chien-Hsuan
    Tsai, Yi-Che
    Wang, Chih-Hung
    Ho, Tzong-Shiann
    Chang, Chih-Peng
    Lee, Gwo-Bin
    MICROFLUIDICS AND NANOFLUIDICS, 2014, 16 (03) : 501 - 512
  • [5] A disposable microfluidic chip for rapid and sensitive detection of plasma biomarkers
    Zirath, H.
    Peham, J.
    Schnetz, G.
    Brandhoff, L.
    Spittler, A.
    Wiesinger-Mayr, H.
    Vellekoop, M. J.
    Redl, H.
    28TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS (EUROSENSORS 2014), 2014, 87 : 496 - 499
  • [6] Rapid, Sensitive, and Quantitative Detection of Pathogenic DNA at the Point of Care through Microfluidic Electrochemical Quantitative Loop-Mediated Isothermal Amplification
    Hsieh, Kuangwen
    Patterson, Adriana S.
    Ferguson, B. Scott
    Plaxco, Kevin W.
    Soh, H. Tom
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2012, 51 (20) : 4896 - 4900
  • [7] Rapid and semiquantitative detection of Staphylococcus epidermidis in humor samples by microfluidic platform
    Zhang, Xinlian
    Li, Xiaoxu
    Liu, Qi
    Ke, Shaorui
    Ji, Yinghong
    Liu, Sixiu
    Sui, Guodong
    SENSORS AND ACTUATORS B-CHEMICAL, 2019, 278 : 8 - 14
  • [8] A self-driven microfluidic immunosensor for rapid separation, enrichment, and detection of biomarkers in serum
    Zhong, Zihui
    Dong, Jianwei
    Xia, Ling
    He, Jincan
    Li, Gongke
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024,
  • [9] Microfluidic immunosensor for rapid and sensitive detection of bovine viral diarrhea virus
    Heinze, Brian C.
    Song, Jae-Young
    Lee, Chang-Hee
    Najam, Anbar
    Yoon, Jeong-Yeol
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 138 (02) : 491 - 496
  • [10] Microfluidic chip with integrated separation, mixing, and concentration operations for rapid and sensitive bacterial detection utilizing synthetic inorganic antibodies
    Nam, Young-Ho
    Lee, Sin
    Lee, Seung-Ki
    Kim, Jong -Ho
    Park, Jae-Hyoung
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 404