Methods and reproducibility of cardiac/respiratory double-triggered 1H-MR spectroscopy of the human heart

被引:0
作者
Felblinger, J
Jung, B
Slotboom, J
Boesch, C
Kreis, R [1 ]
机构
[1] Univ Bern, Dept Clin Res, Sect MR Spect & Methodol, MR Ctr 1, CH-3010 Bern, Switzerland
[2] Inselspital Bern, Dept Clin Res, Sect MR Spect & Methodol, MR Ctr 1, Bern, Switzerland
关键词
ECG; respiration; gating; creatine; lipids; reproducibility; motion; MRI;
D O I
10.1002/(SICI)1522-2594(199911)42:5<903::AID-MRM10>3.3.CO;2-E
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Localized H-1-MR spectroscopy is sensitive to motion and has mostly been applied to the brain. For the human heart, cardiac and respiratory motion lead to displacements on the order of the localized voxel and lead to substantial Variations of voxel content, lineshape, water suppression, and signal phase and amplitude. Combined respiratory and cardiac double triggering can avoid these complications to a large extent, Three methods of double triggering are evaluated, with reproducibility established in nine subjects for a method based on respiratory modulation of the ECG amplitude and a Visual feedback mechanism. Quantitated with respect to water, within-subject reproducibilities for this setup were 9% for trimethylammonium compounds, 10% for creatine/phosphocreatine, and 13% for lipids, ANOVA showed significant differences between subjects which may relate to natural variability between subjects or exact location within the heart. Unresolved issues for this technique are its susceptibility to precise placement of ECG electrodes and the reasons for failure in 20% of examination. With this technique it is possible to investigate open questions in cardiac pathophysiology, such as the creatine content in chronic heart disease. Variants of this triggering method may also improve cardiovascular MRI methods relying on data acquired in several heartbeats. Magn Reson Med 42:903-910, 1999, (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:903 / 910
页数:8
相关论文
共 40 条
  • [1] H-1 NMR measurement of triacylglycerol accumulation in the post ischemic canine heart after transient increase of plasma lipids
    Balschi, JA
    Hai, JO
    Wolkowicz, PE
    StraeterKnowlen, I
    Evanochko, WT
    Caulfield, JB
    Bradley, E
    Ku, DD
    Pohost, GM
    [J]. JOURNAL OF MOLECULAR AND CELLULAR CARDIOLOGY, 1997, 29 (02) : 471 - 480
  • [2] BALSOM PD, 1996, ACTA PHYSL SCAND, V158, P195
  • [3] In vivo determination of intra-myocellular lipids in human muscle by means of localized H-1-MR-spectroscopy
    Boesch, C
    Slotboom, J
    Hoppeler, H
    Kreis, R
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (04) : 484 - 493
  • [4] BOESCH C, 1996, MAGN RESON MATER PHY, V4, P154
  • [5] Non-invasive magnetic-resonance detection of creatine depletion in non-viable infarcted myocardium
    Bottomley, PA
    Weiss, RG
    [J]. LANCET, 1998, 351 (9104) : 714 - 718
  • [6] Diffusion-weighted interleaved echo-planar imaging with a pair of orthogonal navigator echoes
    Butts, K
    deCrespigny, A
    Pauly, JM
    Moseley, M
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (05) : 763 - 770
  • [7] OBSERVATION OF CARDIAC LIPIDS IN HUMANS BY LOCALIZED H-1 MAGNETIC-RESONANCE SPECTROSCOPIC IMAGING
    DENHOLLANDER, JA
    EVANOCHKO, WT
    POHOST, GM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (02) : 175 - 180
  • [8] ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES
    EHMAN, RL
    FELMLEE, JP
    [J]. RADIOLOGY, 1989, 173 (01) : 255 - 263
  • [9] STRUCTURAL STUDIES OF NMR DETECTED LIPIDS IN MYOCARDIAL-ISCHEMIA
    EVANOCHKO, WT
    POHOST, GM
    [J]. NMR IN BIOMEDICINE, 1994, 7 (06) : 269 - 277
  • [10] Felblinger J, 1998, NMR BIOMED, V11, P107, DOI 10.1002/(SICI)1099-1492(199805)11:3<107::AID-NBM525>3.0.CO