Study of constraints in using household NaCl salt for retrospective dosimetry

被引:29
作者
Elashmawy, M. [1 ]
机构
[1] ENRRA, Cairo, Egypt
关键词
Thermoluminescence; Retrospective dosimetry; NaCl; Particle size; TL kinetics; OPTICALLY STIMULATED LUMINESCENCE; REGENERATIVE-DOSE PROTOCOL; ELECTRONIC COMPONENTS; ACCIDENT DOSIMETRY; QUARTZ; CERAMICS; EMISSION; BRICKS; OSL;
D O I
10.1016/j.nimb.2018.03.016
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Thermoluminescence (TL) characteristics of 5 different household NaCl salts and one analytical salt were determined to investigate the possible factors that affect the reliability of using household salt for retrospective dosimetry. Salts' TL sensitivities were found to be particle-size dependent and approached saturation at the largest size, whereas for salts that have the same particle size, the TL sensitivity depended on their origin. TL dependence on the particle size interprets significant variations in TL response reported in the literature for the same salt patch. The first TL readout indicated that all salts have similar glow curves with one distinctive peak. Typical second TL readout at two different doses showed a dramatic decrease in TL sensitivity associated with a significant change in the glow curve structure possessing two prominent peaks. Glow curve deconvolution (GCD) of the first TL readout for all salts yielded 6 individual glow peaks of first-order kinetics, whereas in GCD of second TL readouts, 5 individual glow peaks of second-order kinetics were obtained. Similarities in the glow curve structures of the first and second TL readouts suggest that additives such as KIO3 and MgCO3 have no effect on the TL process. Fading effect was evaluated for the salt of highest TL sensitivity, and it was found that the integral TL intensity decreased gradually and lost 40% of its initial value over 2 weeks, after which it remained constant. Results conclude that a household salt cannot be used for retrospective dosimetry without considering certain constraints such as the salt's origin and particle size. Furthermore, preparedness for radiological accidents and accurate dose reconstructions require that most of the commonly distributed household salt brands should be calibrated in advance and stored in a repository to be recalled in case of accidents.
引用
收藏
页码:49 / 61
页数:13
相关论文
共 50 条
[11]  
Chen R., 1997, THEORY THERMOLUMINES, DOI DOI 10.1142/9789812830890_0007
[12]   USING AN OPTIMISED OSL SINGLE-ALIQUOT REGENERATIVE-DOSE PROTOCOL FOR LOW-DOSE RETROSPECTIVE DOSIMETRY ON HOUSEHOLD SALT [J].
Christiansson, M. ;
Bernhardsson, C. ;
Mattsson, S. ;
Raaf, C. L. .
RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) :584-587
[13]  
Christiansson M., 2016, R43216 CONG RES SERV, P1
[14]   STUDY OF THE SUITABILITY OF ISRAELI HOUSEHOLD SALT FOR RETROSPECTIVE DOSIMETRY [J].
Datz, Hanan ;
Druzhyna, Sofia ;
Oster, Leonid ;
Orion, Itzhak ;
Horowitz, Yigal .
RADIATION PROTECTION DOSIMETRY, 2016, 170 (1-4) :407-411
[15]  
David M., 2014, PROG NUCL SCI TECHNO, V4, P692
[16]   Tooth Retrospective Dosimetry Using Electron Paramagnetic Resonance: Influence of Irradiated Dental Composites [J].
Desmet, Celine M. ;
Djurkin, Andrej ;
Dos Santos-Goncalvez, Ana Maria ;
Dong, Ruhong ;
Kmiec, Maciej M. ;
Kobayashi, Kyo ;
Rychert, Kevin ;
Beun, Sebastien ;
Leprince, Julian G. ;
Leloup, Gaetane ;
Leveque, Philippe ;
Gallez, Bernard .
PLOS ONE, 2015, 10 (06)
[17]   Thermoluminescence characteristics of Israeli household salts for retrospective dosimetry in radiological events [J].
Druzhyna, S. ;
Datz, H. ;
Horowitz, Y. S. ;
Oster, L. ;
Orion, I. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 377 :67-76
[18]   Tooth enamel as a detector material for retrospective EPR dosimetry [J].
Egersdorfer, S ;
Wieser, A ;
Muller, A .
APPLIED RADIATION AND ISOTOPES, 1996, 47 (11-12) :1299-1303
[19]   NaCl as a retrospective and accident dosemeter [J].
Ekendahl, Daniela ;
Judas, Libor .
RADIATION PROTECTION DOSIMETRY, 2011, 145 (01) :36-44
[20]  
El -Nagger A. M., 2001, P 4 INT REAC TS C ME