The Effect of Optive and Optive Advanced Artificial Tears on the Healthy Tear Film

被引:14
作者
Markoulli, Maria [1 ]
Sobbizadeh, Amanda [1 ]
Tan, Jacqueline [1 ]
Briggs, Nancy [2 ]
Coroneo, Minas [3 ]
机构
[1] UNSW Sydney, Sch Optometry & Vis Sci, Fac Sci, Sydney, NSW, Australia
[2] UNSW Sydney, Stats Cent, Mark Wainwright Analyt Ctr, Sydney, NSW, Australia
[3] UNSW Sydney, Dept Ophthalmol, Prince Wales Clin Sch, Fac Med, Sydney, NSW, Australia
关键词
Artificial tears; lipid layer thickness; tear film break-up time; dry eye; LIPID LAYER THICKNESS; DRY EYE DISEASE; WATER EMULSION; OIL; MULTICENTER; EVAPORATION; DROP; HYPEROSMOLARITY; EYEDROPS;
D O I
10.1080/02713683.2018.1433860
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the impact of Optive (Allergan, Irvine, CA) and Optive Advanced (Allergan, Irvine, CA) on tear film stability and quality during a one-hour observation period when compared to saline (Pfizer, Perth, WA).Methods: This was a double-masked, cross-over study. Twenty participants attended three visits, randomly receiving either Optive, Optive Advanced or saline. Oculus Keratograph 5M (Oculus, Arlington, WA, USA), non-invasive keratograph break-up time (NIKBUT), Lipiview (TearScience Inc, Morrisville, NC, USA), lipid layer thickness (LLT) and comfort were measured prior to and 5, 15 and 60min after drop instillation.Results: Optive Advanced demonstrated a significant increase in LLT between baseline (57.512.3nm) and both 5min (67.5 +/- 18.8nm, p=0.04) and 15min (68.9 +/- 17.3nm, p=0.04) but not 60min (61.6 +/- 14.3nm, p=0.47). Optive and saline were not different between timepoints for LLT (p>0.05). There was no difference between timepoints for any of the drops for NIKBUT (p=0.75). Comfort was significantly better at 5min compared to baseline for Optive (8.3 +/- 1.2 and 7.3 +/- 1.4, respectively, p=0.03) but not different for Optive Advance or saline (p>0.05).Conclusions: Optive Advanced increased LLT for 15min following instillation, returning to baseline within one hour. This did not however, translate into an improvement in tear film stability over this time period. Only Optive demonstrated an improvement in comfort.
引用
收藏
页码:588 / 594
页数:7
相关论文
共 50 条
  • [41] Effect of Ambient Temperature on the Human Tear Film
    Abusharha, Ali A.
    Pearce, E. Ian
    Fagehi, Raied
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2016, 42 (05): : 308 - 312
  • [42] The Effect of the Lipid Layer on Tear Film Behaviour
    M. B. Jones
    D. L. S. McElwain
    G. R. Fulford
    M. J. Collins
    A. P. Roberts
    Bulletin of Mathematical Biology, 2006, 68 : 1355 - 1381
  • [43] Changes in Tear Lipid Layer Thickness and Symptoms Following the Use of Artificial Tears with and Without Omega-3 Fatty Acids: A Randomized, Double-Masked, Crossover Study
    Fogt, Jennifer S.
    Fogt, Nick
    King-Smith, P. Ewen
    Liu, Haixia
    Barr, Joseph T.
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 2553 - 2561
  • [44] Effect of artificial tears on dynamic optical quality in patients with dry eye disease
    Wei, Zhenyu
    Su, Yuandong
    Su, Guanyu
    Baudouin, Christophe
    Labbe, Antoine
    Liang, Qingfeng
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [45] Effect of hyaluronic acid on tear film thickness as assessed with ultra-high resolution optical coherence tomography
    Kaya, Semira
    Schmidl, Doreen
    Schmetterer, Leopold
    Witkowska, Katarzyna J.
    Unterhuber, Angelika
    dos Santos, Valentin Aranha
    Baar, Carina
    Garhoefer, Gerhard
    Werkmeister, Rene M.
    ACTA OPHTHALMOLOGICA, 2015, 93 (05) : 439 - 443
  • [46] EFFECT OF ARTIFICIAL TEARS ON CULTURED KERATOCYTES IN-VITRO
    WEE, WR
    WANG, XW
    MCDONNELL, PJ
    CORNEA, 1995, 14 (03) : 273 - 279
  • [47] Effect of virtual reality headset wear on the tear film: A randomised crossover study
    Turnbull, Philip R. K.
    Wong, Joyce
    Feng, Jasmine
    Wang, Michael T. M.
    Craig, Jennifer P.
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (06) : 640 - 645
  • [48] Effect of Loose Masks on Tear-film Break-up Time
    Lee, Jooheon
    Ahn, Minwon
    Choi, Jaewon
    Park, Minji
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (05): : 367 - 373
  • [49] Tear film evaporation-Effect of age and gender
    Guillon, Michel
    Maissa, Cecile
    CONTACT LENS & ANTERIOR EYE, 2010, 33 (04) : 171 - 175
  • [50] The effect of smoking on the ocular surface and the precorneal tear film
    Thomas, Jyothi
    Jacob, George P.
    Abraham, Lekha
    Noushad, Babu
    AUSTRALASIAN MEDICAL JOURNAL, 2012, 5 (04): : 221 - 226