The Effect of Optive and Optive Advanced Artificial Tears on the Healthy Tear Film

被引:14
|
作者
Markoulli, Maria [1 ]
Sobbizadeh, Amanda [1 ]
Tan, Jacqueline [1 ]
Briggs, Nancy [2 ]
Coroneo, Minas [3 ]
机构
[1] UNSW Sydney, Sch Optometry & Vis Sci, Fac Sci, Sydney, NSW, Australia
[2] UNSW Sydney, Stats Cent, Mark Wainwright Analyt Ctr, Sydney, NSW, Australia
[3] UNSW Sydney, Dept Ophthalmol, Prince Wales Clin Sch, Fac Med, Sydney, NSW, Australia
关键词
Artificial tears; lipid layer thickness; tear film break-up time; dry eye; LIPID LAYER THICKNESS; DRY EYE DISEASE; WATER EMULSION; OIL; MULTICENTER; EVAPORATION; DROP; HYPEROSMOLARITY; EYEDROPS;
D O I
10.1080/02713683.2018.1433860
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the impact of Optive (Allergan, Irvine, CA) and Optive Advanced (Allergan, Irvine, CA) on tear film stability and quality during a one-hour observation period when compared to saline (Pfizer, Perth, WA).Methods: This was a double-masked, cross-over study. Twenty participants attended three visits, randomly receiving either Optive, Optive Advanced or saline. Oculus Keratograph 5M (Oculus, Arlington, WA, USA), non-invasive keratograph break-up time (NIKBUT), Lipiview (TearScience Inc, Morrisville, NC, USA), lipid layer thickness (LLT) and comfort were measured prior to and 5, 15 and 60min after drop instillation.Results: Optive Advanced demonstrated a significant increase in LLT between baseline (57.512.3nm) and both 5min (67.5 +/- 18.8nm, p=0.04) and 15min (68.9 +/- 17.3nm, p=0.04) but not 60min (61.6 +/- 14.3nm, p=0.47). Optive and saline were not different between timepoints for LLT (p>0.05). There was no difference between timepoints for any of the drops for NIKBUT (p=0.75). Comfort was significantly better at 5min compared to baseline for Optive (8.3 +/- 1.2 and 7.3 +/- 1.4, respectively, p=0.03) but not different for Optive Advance or saline (p>0.05).Conclusions: Optive Advanced increased LLT for 15min following instillation, returning to baseline within one hour. This did not however, translate into an improvement in tear film stability over this time period. Only Optive demonstrated an improvement in comfort.
引用
收藏
页码:588 / 594
页数:7
相关论文
共 50 条
  • [21] Dynamic Changes in the Lower Tear Meniscus After Instillation of Artificial Tears
    Wang, Yan
    Zhuang, Hong
    Xu, Jianjiang
    Wang, Xin
    Jiang, Chunhui
    Sun, Xinghuai
    CORNEA, 2010, 29 (04) : 404 - 408
  • [22] More to Stable Tears Than Thickness of the Tear Film Lipid Layer
    Fenner, Beau J.
    Tong, Louis
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (03) : 1601 - 1601
  • [23] Divalent Cations in Tears, and Their Influence on Tear Film Stability in Humans and Rabbits
    Wei, Xiaojia Eric
    Markoulli, Maria
    Millar, Thomas J.
    Willcox, Mark D. P.
    Zhao, Zhenjun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) : 3280 - 3285
  • [24] Lipidomic study in human and rabbit tears: implications for tear film stability
    Wei, Eric Xiaojia
    Zhao, Zhenjun
    Willcox, Mark D. P.
    CHEMISTRY AND PHYSICS OF LIPIDS, 2010, 163 : S31 - S31
  • [25] Effects of Topical Cyclosporine A Plus Artificial Tears Versus Artificial Tears Treatment on Conjunctival Goblet Cell Density in Dysfunctional Tear Syndrome
    Demiryay, Elvan
    Yaylali, Volkan
    Cetin, Ebru Nevin
    Yildirim, Cem
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (05): : 312 - 315
  • [26] The impact of pseudoexfoliation and artificial tear application on the tear film stability in a pseudophakic eye
    Todorovic, Dusan
    Sarenac-Vulovic, Tatjana
    Jovanovic, Svetlana
    Janicijevic-Petrovic, Mirjana
    Petrovic, Nenad
    Kontic, Marko
    Todorovic, Milos
    Janicijevic, Katarina
    Sreckovic, Suncica
    SRPSKI ARHIV ZA CELOKUPNO LEKARSTVO, 2018, 146 (7-8) : 422 - 427
  • [27] Effect of 0.15% sodium hyaluronate on tear film breakup time in healthy anesthetized cats
    Madruga, Gabriela Moraes
    Ribeiro, Alexandre Pinto
    Martins, Leticia Ramos
    VETERINARY OPHTHALMOLOGY, 2023, 26 (01) : 46 - 52
  • [28] Effect of a Commercially Available Warm Compress on Eyelid Temperature and Tear Film in Healthy Eyes
    Bilkhu, Paramdeep S.
    Naroo, Shehzad A.
    Wolffsohn, James S.
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (02) : 163 - 170
  • [29] Tear film osmolality and electrolyte composition in healthy horses
    Best, Lori J.
    Hendrix, Diane V. H.
    Ward, Daniel A.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2015, 76 (12) : 1066 - 1069
  • [30] Improvement of tear ferning patterns of artificial tears using dilute electrolyte solutions
    Almutleb, Essam S.
    Altoaimi, Basal H.
    El-Hiti, Gamal A.
    Alotaibi, Abdullah G.
    Baashen, Mashaaer A.
    Alanazi, Saud A.
    Masmali, Ali M.
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2023, 35 (08)