Two Femtosecond Laser LASIK Platforms: Comparison of Evolution of Visual Acuity, Flap Thickness, and Stromal Optical Density

被引:8
作者
Parafita-Fernandez, Alberto [1 ,2 ]
Garcia-Gonzalez, Montserrat [1 ,3 ]
Katsanos, Andreas [4 ]
Gros-Otero, Juan [3 ]
Teus, Miguel [1 ,5 ]
机构
[1] Clin Novovis, Madrid, Spain
[2] Complexo Hosp Univ Pontevedra, Dept Ophthalmol, Pontevedra, Spain
[3] Clin Rementeria, Madrid, Spain
[4] Univ Ioannina, Dept Ophthalmol, Ioannina, Greece
[5] Univ Alcala, Dept Ophthalmol, Madrid, Spain
关键词
femtosecond LASIK; patient interface; multifunctional femtosecond laser; corneal flap morphology; IN-SITU KERATOMILEUSIS; MYOPIC LASIK; MICROKERATOME; ASTIGMATISM; MORPHOLOGY; CREATION; OUTCOMES;
D O I
10.1097/ICO.0000000000001784
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare postoperative evolution of visual acuity, flap thickness, and stromal optical density during the first 3 months after femtosecond (FS) laser in situ keratomileusis surgery for correction of myopia using the iFS 150-kHz FS laser and LenSx FS laser platforms. Methods: This was a prospective case series. Thirty-nine eyes treated with the iFS 150-kHz FS laser versus 38 refraction-matched eyes treated with the LenSx FS laser platform were included. Visual outcomes, flap morphology, and optical density of the stroma (in both flap and residual stromal bed) were compared at 4 visits during a three-month follow-up period. Results: No significant differences were found in uncorrected distance visual acuity in any of the follow-up visits (1 day -0.02 vs. -0.03; 1 week -0.04 vs. -0.03; 1 month -0.04 vs. -0.04; 3 months -0.03 vs. -0.05 logarithm of the minimum angle of resolution). Flaps created with the iFS 150-kHz FS laser were closer to the intended thickness (110 mm) in every postoperative comparison (1 day 108.6 vs. 124.3; 1 week 107.6 vs. 123.6; 1 month 110.4 vs. 126.8; 3 months 116.2 vs. 126.5 mm; P< 0.0001). Dispersion of values, standard deviation, intraflap range, and differences in symmetric points were lower in the iFS 150-kHz FS laser group. Flap stromal optical density was significantly higher in the LenSx FS laser group at day 1 and week 1 (134.5 vs. 158.9 gray scale unit [GSU]; P< 0.0001 and 144.8 vs. 160.1 GSU; P = 0.011, respectively). Residual stromal bed optical density was higher in the LenSx FS laser group at all postoperative visits, and the differences reached significance at 1 week postoperatively (121.9 vs. 135.4 GSU; P = 0.03). Conclusions: Although both devices provided satisfactory visual outcomes, significant differences were detected in flap parameters. Flaps made with the iFS 150-kHz FS laser were thinner, more uniform, transparent, and accurate compared with those obtained with the LenSx FS laser.
引用
收藏
页码:98 / 104
页数:7
相关论文
共 17 条
[1]   Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome [J].
Ahn, Hyunseok ;
Kim, Jin-Kook ;
Kim, Chang Kook ;
Han, Gyu Heon ;
Seo, Kyoung Yul ;
Kim, Eung Kweon ;
Kim, Tae-im .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02) :349-357
[2]   Femtosecond Lasers for LASIK Flap Creation A Report by the American Academy of Ophthalmology [J].
Farjo, Ayad A. ;
Sugar, Alan ;
Schallhorn, Steven C. ;
Majmudar, Parag A. ;
Tanzer, David J. ;
Trattler, William B. ;
Cason, John B. ;
Donaldson, Kendall E. ;
Kymionis, George D. .
OPHTHALMOLOGY, 2013, 120 (03) :E5-E20
[3]   Comparison of visual outcomes and flap morphology using 2 femtosecond-laser platforms [J].
Garcia-Gonzalez, Montserrat ;
Bouza-Miguens, Carmen ;
Parafita-Fernandez, Alberto ;
Gros-Otero, Juan ;
Canones-Zafra, Rafael ;
Villa-Collar, Cesar ;
Teus, Miguel A. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (01) :78-84
[4]   Porcine model to compare real-time intraocular pressure during LASIK with a mechanical microkeratome and femtosecond laser [J].
Hernandez-Verdejo, Jose L. ;
Teus, Miguel A. ;
Roman, Jose M. ;
Bolivar, Gema .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) :68-72
[5]  
Juhasz E, 2015, J REFRACT SURG, V31, P140
[6]   Analysis of Planned and Postoperatively Measured Flap Thickness After LASIK Using the LenSx Multifunctional Femtosecond Laser System [J].
Juhasz, Eva ;
Filkorn, Tamas ;
Kranitz, Kinga ;
Sandor, Gabor Laszlo ;
Gyenes, Andrea ;
Nagy, Zoltan Zsolt .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (09) :622-U50
[7]   Comparison of corneal flaps created by Wavelight FS200 and Intralase FS60 femtosecond lasers [J].
Liu, Qian ;
Zhou, Yue-Hua ;
Zhang, Jing ;
Zheng, Yan ;
Zhai, Chang-Bin ;
Liu, Jing .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (07) :1006-1010
[8]   A Prospective Randomized Comparison of Four Femtosecond LASIK Flap Thicknesses [J].
Prakash, Gaurav ;
Agarwal, Amar ;
Yadav, Anil ;
Jacob, Soosan ;
Kumar, Dhivya Ashok ;
Agarwal, Athiya ;
Akhtar, Raheel .
JOURNAL OF REFRACTIVE SURGERY, 2010, 26 (06) :392-402
[9]   Change in Epithelial Thickness Profile 24 Hours and Longitudinally for 1 Year After Myopic LASIK: Three-dimensional Display With Artemis Very High-frequency Digital Ultrasound [J].
Reinstein, Dan Z. ;
Archer, Timothy J. ;
Gobbe, Marine .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) :195-U122
[10]   Spectral-Domain Optical Coherence Tomography Epithelial and Flap Thickness Mapping in Femtosecond Laser-Assisted In Situ Keratomileusis [J].
Rocha, Karolinne Maia ;
Krueger, Ronald R. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 158 (02) :293-301