Online Fault Detection in PV Systems

被引:186
作者
Platon, Radu [1 ]
Martel, Jacques [1 ]
Woodruff, Norris
Chau, Tak Y.
机构
[1] CanmetENERGY, Nat Resources Canada, Varennes, PQ J3X 1S6, Canada
关键词
Data analysis; fault detection; lagging; normal operation; online implementation; performance ratio (PR); predictive model; photovoltaic (PV) systems;
D O I
10.1109/TSTE.2015.2421447
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents the development of a practical fault detection approach in photovoltaic (PV) systems, intended for online implementation. The approach was developed and validated using field measurements from a Canadian PV system. It has a fairly low degree of complexity, but achieves a high fault detection rate and is able to successfully cope with abnormalities present in real-life measurements. The fault detection is based on the comparison between the measured and model prediction results of the ac power production. The model estimates the ac power production using solar irradiance and PV panel temperature measurements. Prior to model development, a data analysis procedure was used to identify values not representative of a normal PV system operation. The original 10-minmeasurements were averaged over 1 h, and both datasets were used for modeling. In order to better represent the PV system performance at different sunlight levels, models for different irradiance ranges were developed. The results reveal that the models based on hourly averages are more accurate than the models using 10-min measurements, and the models for different irradiance intervals lead to a fault detection rate greater than 90%. The PV system performance ratio (PR) was used to keep track of the system's long-term performance.
引用
收藏
页码:1200 / 1207
页数:8
相关论文
共 27 条
[1]  
Bunea G, 2006, 4 WORLD C PHOT EN C
[2]   Modeling and fault diagnosis of a photovoltaic system [J].
Chao, K. -H. ;
Ho, S-H. ;
Wang, M. -H. .
ELECTRIC POWER SYSTEMS RESEARCH, 2008, 78 (01) :97-105
[3]   Automatic supervision and fault detection of PV systems based on power losses analysis [J].
Chouder, A. ;
Silvestre, S. .
ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (10) :1929-1937
[4]   Modeling and simulation of a grid connected PV system based on the evaluation of main PV module parameters [J].
Chouder, Aissa ;
Silvestre, Santiago ;
Sadaoui, Nawel ;
Rahmani, Lazhar .
SIMULATION MODELLING PRACTICE AND THEORY, 2012, 20 (01) :46-58
[5]   Monitoring and remote failure detection of grid-connected PV systems based on satellite observations [J].
Drews, A. ;
de Keizer, A. C. ;
Beyer, H. G. ;
Lorenz, E. ;
Betcke, J. ;
van Sark, W. G. J. H. M. ;
Heydenreich, W. ;
Wiemken, E. ;
Stettler, S. ;
Toggweiler, P. ;
Bofinger, S. ;
Schneider, M. ;
Heilscher, G. ;
Heinemann, D. .
SOLAR ENERGY, 2007, 81 (04) :548-564
[6]  
Drews A., 2004, EUR 5 ISES EUR SOL C
[7]   A simple model of PV system performance and its use in fault detection [J].
Firth, S. K. ;
Lomas, K. J. ;
Rees, S. J. .
SOLAR ENERGY, 2010, 84 (04) :624-635
[8]   Simple diagnostic approach for determining of faulted PV modules in string based PV arrays [J].
Gokmen, Nuri ;
Karatepe, Engin ;
Celik, Berk ;
Silvestre, Santiago .
SOLAR ENERGY, 2012, 86 (11) :3364-3377
[9]  
Guasch D., 2003, 3 WORLD C PHOT EN CO
[10]  
Hamdaoui M., 2009, INT REN EN C POZN PO