Rapid and reliable self-screening for nutritional risk in hospital outpatients using an electronic system

被引:21
作者
McGurk, Paula [1 ]
Jackson, John M. [2 ,3 ]
Elia, Marinos [2 ,3 ,4 ]
机构
[1] Southampton Univ Hosp NHS Fdn Trust, Dept Dietet, Southampton, Hants, England
[2] Univ Southampton, Southampton NIHR Biomed Res Ctr Nutr, Southampton, Hants, England
[3] Southampton Univ Hosp NHS Fdn Trust, Southampton, Hants, England
[4] Univ Southampton, Inst Human Nutr, Southampton, Hants, England
关键词
Nutritional screening; Self-screening; Electronic; MUST; Hospital outpatients; VALIDITY; RELIABILITY; EASE;
D O I
10.1016/j.nut.2012.12.020
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
Objective: This study examined an electronic nutritional self-screening procedure for feasibility and for reliability, rapidity, and ease of use by hospital outpatients. Methods: One hundred sixty consecutive patients (ages 18-87 y) attending a gastroenterology clinic measured their weight and height using a modified digital weight and height machine, which transmitted results to a computer. Following input of reported weight loss in the previous 3 mo to 6 mo, malnutrition risk by the Malnutrition Universal Screening Tool (MUST) was instantaneously calculated. The duration and ease of undertaking screening were noted. Screening also was undertaken by a health care professional. Results: Of the patients in the study, 21.3% were at risk for malnutrition (medium + high risk). There was perfect agreement (kappa = 1.00) between self-screening and health care professional screening, between test-retest self-screening, and between two methods of measuring height (facing toward and away from the stadiometer). A low within-patient coefficient of variation was found for measurement of weight (<0.2%), height (<0.35%) and body mass index (<0.4%), except for two measurements in which height was recorded before correct positioning of the sliding headpiece. The overall time to self-screen was 1.29 +/- 0.57 min but it was 2.81 +/- 0.92 min in those aged >= 75 y. Of the participants, 96.2% rated self-screening as very easy (71.9%) or easy (24.3%) and 3.8% (predominantly patients ages >= 75 y) difficult. Conclusion: The study provides evidence that electronic nutritional self-screening can be rapid, easy, reliable, and feasible in a clinical setting. Equipment specifically designed for self-screening and use in other types of patients and settings could facilitate appropriate and routine implementation of self-screening. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:693 / 696
页数:4
相关论文
共 8 条
[1]   Nutrition screen showed good agreement when self- and interviewer administered [J].
Beath, Heather ;
Keller, Heather H. .
JOURNAL OF CLINICAL EPIDEMIOLOGY, 2007, 60 (10) :1085-1089
[2]  
Brownie S, 2007, J NUTR HEALTH AGING, V11, P20
[3]   Malnutrition self-screening by using MUST in hospital outpatients: validity, reliability, and ease of use [J].
Cawood, Abbie L. ;
Elia, Marinos ;
Sharp, Sarah K. E. ;
Stratton, Rebecca J. .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2012, 96 (05) :1000-1007
[4]  
Cawood AL, 2011, CLIN NUTR S, V6, P68
[5]   An analytic appraisal of nutrition screening tools supported by original data with particular reference to age [J].
Elia, Marinos ;
Stratton, Rebecca J. .
NUTRITION, 2012, 28 (05) :477-494
[6]   Validity and reliability of SCREEN II (Seniors in the Community: Risk evaluation for eating and nutrition, Version II) [J].
Keller, HH ;
Goy, R ;
Kane, SL .
EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2005, 59 (10) :1149-1157
[7]   FIELD TRIAL AFFIRMS VALUE OF DETERMINING NUTRITION-RELATED PROBLEMS OF FREE-LIVING ELDERLY [J].
SPANGLER, AA ;
EIGENBROD, JS .
JOURNAL OF THE AMERICAN DIETETIC ASSOCIATION, 1995, 95 (04) :489-490
[8]   Malnutrition in hospital outpatients and inpatients: prevalence, concurrent validity and ease of use of the 'malnutrition universal screening tool' ('MUST') for adults [J].
Stratton, RJ ;
Hackston, A ;
Longmore, D ;
Dixon, R ;
Price, S ;
Stroud, M ;
King, C ;
Elia, M .
BRITISH JOURNAL OF NUTRITION, 2004, 92 (05) :799-808