Improved porous silicon microarray based prostate specific antigen immunoassay by optimized surface density of the capture antibody

被引:19
作者
Lee, SangWook [1 ,2 ]
Kim, Soyoun [2 ]
Malm, Johan [3 ]
Jeong, Ok Chan [4 ]
Lilja, Hans [3 ,5 ,6 ,7 ,8 ,9 ]
Laurell, Thomas [2 ,10 ]
机构
[1] Riken Inst Phys & Chem Res, Bioengn Lab, Saitama, Japan
[2] Dongguk Univ, Dept Biomed Engn, Seoul, South Korea
[3] Lund Univ, Skane Univ Hosp Malmo, Div Clin Chem, Dept Lab Med, S-20502 Malmo, Sweden
[4] Inje Univ, Dept Mech Engn, Pusan, South Korea
[5] Mem Sloan Kettering Canc Ctr, Dept Lab Med, New York, NY 10021 USA
[6] Mem Sloan Kettering Canc Ctr, Dept Surg Urol, New York, NY 10021 USA
[7] Mem Sloan Kettering Canc Ctr, Dept Med GU Oncol, New York, NY 10021 USA
[8] Univ Tampere, Inst Biosci & Med Technol, FIN-33101 Tampere, Finland
[9] Univ Oxford, Nuffield Dept Surg Sci, Oxford, England
[10] Lund Univ, Dept Elect Measurements, S-22100 Lund, Sweden
基金
瑞典研究理事会;
关键词
Antibody microarray; Porous silicon; Sandwich immunoassay; Prostate specific antigen; PHASE PROTEIN MICROARRAYS; REVERSE-PHASE; BIOCHEMICAL RECURRENCE; RADICAL PROSTATECTOMY; CANCER; TECHNOLOGY; SERUM; PSA; AMPLIFICATION; ENHANCEMENT;
D O I
10.1016/j.aca.2013.06.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA - prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL(-1), 80 pg mL(1), and 800 fg mL(-1) when arraying the PSA antibody, H117 at the concentration 15 mu g mL(-1), 35 mu g mL(-1), and 154 mu g mL(-1), respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL(-1) to 500 ng mL(-1). The microarray showed a LOD of 800 fg mL(-1) and a dynamic range of 800 fg mL(-1) to 80 ng mL(-1) in serum spiked samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 50 条
  • [31] Digital multimeter-based point-of-care immunoassay of prostate- specific antigen coupling with a flexible photosensitive pressure sensor
    Zhu, Ling
    Lv, Zijian
    Yin, Zipeng
    Li, Meijin
    Tang, Dianping
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2021, 343
  • [32] Signal amplification strategy for sensitive immunoassay of prostate specific antigen (PSA) based on ferrocene incorporated polystyrene spheres
    Ding, Lu
    You, Jinmao
    Kong, Rongmei
    Qu, Fengli
    [J]. ANALYTICA CHIMICA ACTA, 2013, 793 : 19 - 25
  • [33] Novel Prostate Specific Antigen plastic antibody designed with charged binding sites for an improved protein binding and its application in a biosensor of potentiometric transduction
    Rebelo, Mina S. C. R.
    Santos, C.
    Costa-Rodrigues, J.
    Fernandes, M. H.
    Noronha, Joao P.
    Sales, M. Goreti F.
    [J]. ELECTROCHIMICA ACTA, 2014, 132 : 142 - 150
  • [34] On-Chip Mass Spectrometry-Based Immunoassay as a Tool for the Detection of Molecular Species from Prostate-Specific Antigen in Female Serum
    Goc, Sanja
    Jankovic, Miroslava
    [J]. ANALYTICAL LETTERS, 2016, 49 (18) : 2943 - 2952
  • [35] A sensitive label-free biosensor based on Ag2S-sensitived Bi2WO6/BiOBr heterojunction for photoelectrochemical immunoassay of prostate specific antigen
    Chang, Huiqin
    Zhu, Qiying
    Wu, Yuyin
    Liu, Anqi
    Jiang, Meng
    Li, Chuang
    Li, Huiting
    Kong, Ling
    Chen, Zhiwei
    Sang, Feng
    [J]. TALANTA, 2023, 257
  • [36] Ultra-sensitive surface plasmon resonance based immunosensor for prostate-specific antigen using gold nanoparticle-antibody complex
    Cho, Jeong-Woo
    Kang, Da-Yeon
    Jang, Yong-Hark
    Kim, Hyun-Hee
    Min, Junhong
    Oh, Byung-Keun
    [J]. COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2008, 313 : 655 - 659
  • [37] Double ion-exchange reaction-based photoelectrochemical immunoassay for sensitive detection of prostate-specific antigen
    Zhu, Ling
    Lv, Zijian
    Yin, Zipeng
    Tang, Dianping
    [J]. ANALYTICA CHIMICA ACTA, 2021, 1149
  • [38] Interactions of Urea-Based Inhibitors with Prostate-Specific Membrane Antigen for Boron Neutron Capture Therapy
    Hu, Qiaoyu
    Padron, Kevin
    Hara, Daiki
    Shi, Junwei
    Pollack, Alan
    Prabhakar, Rajeev
    Tao, Wensi
    [J]. ACS OMEGA, 2021, 6 (49): : 33354 - 33369
  • [39] A highly sensitive capillary electrophoresis immunoassay strategy based on dual-labeled gold nanoparticles enhancing chemiluminescence for the detection of prostate-specific antigen
    Li, Shuting
    Shi, Min
    Zhao, Jingjin
    Zhang, Liangliang
    Huang, Yong
    Zhao, Shulin
    [J]. ELECTROPHORESIS, 2017, 38 (13-14) : 1780 - 1787
  • [40] Gold nanoparticle triggered dual optoplasmonic-impedimetric sensing of prostate-specific antigen on interdigitated porous silicon platforms
    Rodriguez, C.
    Torres-Costa, V.
    Ahumada, O.
    Cebrian, V.
    Gomez-Abad, C.
    Diaz, A.
    Manso Silvan, M.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 267 : 559 - 564