Improved porous silicon microarray based prostate specific antigen immunoassay by optimized surface density of the capture antibody

被引:19
|
作者
Lee, SangWook [1 ,2 ]
Kim, Soyoun [2 ]
Malm, Johan [3 ]
Jeong, Ok Chan [4 ]
Lilja, Hans [3 ,5 ,6 ,7 ,8 ,9 ]
Laurell, Thomas [2 ,10 ]
机构
[1] Riken Inst Phys & Chem Res, Bioengn Lab, Saitama, Japan
[2] Dongguk Univ, Dept Biomed Engn, Seoul, South Korea
[3] Lund Univ, Skane Univ Hosp Malmo, Div Clin Chem, Dept Lab Med, S-20502 Malmo, Sweden
[4] Inje Univ, Dept Mech Engn, Pusan, South Korea
[5] Mem Sloan Kettering Canc Ctr, Dept Lab Med, New York, NY 10021 USA
[6] Mem Sloan Kettering Canc Ctr, Dept Surg Urol, New York, NY 10021 USA
[7] Mem Sloan Kettering Canc Ctr, Dept Med GU Oncol, New York, NY 10021 USA
[8] Univ Tampere, Inst Biosci & Med Technol, FIN-33101 Tampere, Finland
[9] Univ Oxford, Nuffield Dept Surg Sci, Oxford, England
[10] Lund Univ, Dept Elect Measurements, S-22100 Lund, Sweden
基金
瑞典研究理事会;
关键词
Antibody microarray; Porous silicon; Sandwich immunoassay; Prostate specific antigen; PHASE PROTEIN MICROARRAYS; REVERSE-PHASE; BIOCHEMICAL RECURRENCE; RADICAL PROSTATECTOMY; CANCER; TECHNOLOGY; SERUM; PSA; AMPLIFICATION; ENHANCEMENT;
D O I
10.1016/j.aca.2013.06.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA - prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL(-1), 80 pg mL(1), and 800 fg mL(-1) when arraying the PSA antibody, H117 at the concentration 15 mu g mL(-1), 35 mu g mL(-1), and 154 mu g mL(-1), respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL(-1) to 500 ng mL(-1). The microarray showed a LOD of 800 fg mL(-1) and a dynamic range of 800 fg mL(-1) to 80 ng mL(-1) in serum spiked samples. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:108 / 114
页数:7
相关论文
共 50 条
  • [11] Magnetic-particle-based, ultrasensitive chemiluminescence enzyme immunoassay for free prostate-specific antigen
    Liu, Ruping
    Wang, Cheng
    Jiang, Quan
    Zhang, Wei
    Yue, Zhao
    Liu, Guohua
    ANALYTICA CHIMICA ACTA, 2013, 801 : 91 - 96
  • [12] Nonlinear hybridization chain reaction-based flow cytometric immunoassay for the detection of prostate specific antigen
    Zeng, Zhuoer
    Zhou, Rong
    Sun, Ruowei
    Zhang, Xun
    Zhang, Di
    Zhu, Qubo
    Chen, Chuanpin
    ANALYTICA CHIMICA ACTA, 2022, 1220
  • [13] Ultrasensitive immunoassay for free prostate-specific antigen based on ferrocenecarboxylate enhanced cathodic electrochemiluminescence of peroxydisulfate
    Zhang, Fei
    Mao, Li
    Zhu, Meiqiong
    MICROCHIMICA ACTA, 2014, 181 (11-12) : 1285 - 1291
  • [14] Electrochemical sandwich immunoassay for the prostate specific antigen using a polyclonal antibody conjugated to thionine and horseradish peroxidase
    Biniaz, Zahra
    Mostafavi, Ali
    Shamspur, Tayebeh
    Torkzadeh-Mahani, Masoud
    Mohamadi, Maryam
    MICROCHIMICA ACTA, 2017, 184 (08) : 2731 - 2738
  • [15] Electrochemical sandwich immunoassay for the prostate specific antigen using a polyclonal antibody conjugated to thionine and horseradish peroxidase
    Zahra Biniaz
    Ali Mostafavi
    Tayebeh Shamspur
    Masoud Torkzadeh-Mahani
    Maryam Mohamadi
    Microchimica Acta, 2017, 184 : 2731 - 2738
  • [16] A Highly Sensitive Porous Silicon (P-Si)-Based Human Kallikrein 2 (hK2) Immunoassay Platform toward Accurate Diagnosis of Prostate Cancer
    Lee, Sang Wook
    Hosokawa, Kazuo
    Kim, Soyoun
    Jeong, Ok Chan
    Lilja, Hans
    Laurell, Thomas
    Maeda, Mizuo
    SENSORS, 2015, 15 (05): : 11972 - 11987
  • [17] A Sensitive Fluorescent Immunoassay for Prostate Specific Antigen Detection Based on Signal Amplify Strategy of Horseradish Peroxidase and Silicon Dioxide Nanospheres
    Li, Lihua
    Zhang, Wenzhi
    Wei, Yan
    Yu, Lizhen
    Feng, Dexiang
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2022, 2022
  • [18] Detection of prostate specific antigen based on electrocatalytic platinum nanoparticles conjugated to a recombinant scFv antibody
    Spain, Elaine
    Gilgunn, Sarah
    Sharma, Shikha
    Adamson, Kellie
    Carthy, Eadaoin
    O'Kennedy, Richard
    Forster, Robert J.
    BIOSENSORS & BIOELECTRONICS, 2016, 77 : 759 - 766
  • [19] Lateral flow immunoassay based on gold magnetic nanoparticles for the protein quantitative detection: Prostate-specific antigen
    Cai, Yu
    Zhang, Shanshan
    Dong, Chen
    Yang, Jiangcun
    Ma, Ting
    Zhang, Hua
    Cui, Yali
    Hui, Wenli
    ANALYTICAL BIOCHEMISTRY, 2021, 627
  • [20] Electrochemical immunoassay for detection of prostate specific antigen based on peptide nanotube-gold nanoparticle-polyaniline immobilized pencil graphite electrode
    Vural, Tayfun
    Yaman, Yesim Tugce
    Ozturk, Serhat
    Abaci, Serdar
    Denkbas, Emir Baki
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2018, 510 : 318 - 326