Efficacy of continuous positive airway pressure for obstructive sleep apnea in overweight patients with type 2 diabetes mellitus

被引:0
|
作者
Chen, Liang [1 ]
Kuang, Jian [1 ]
Pei, Jian-Hao [1 ]
Chen, Hong-Mei [1 ]
Chen, Zhong [1 ]
Li, Zhong-Wen [1 ]
Yang, Hua-Zhang [1 ]
Fu, Xiao-Ying [1 ]
Wang, Long [1 ]
Chen, Zhi-Jiang [1 ]
Lai, Shui-Qing [1 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Gen Hosp, Dept Endocrinol, Div 1, 106th Zhongshan Er Rd, Guangzhou 510080, Guangdong, Peoples R China
来源
INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE | 2016年 / 9卷 / 10期
关键词
Continuous positive airway pressure; obstructive sleep apnea; overweight; type 2 diabetes mellitus; METABOLIC SYNDROME; INTERMITTENT HYPOXIA; GLUCOSE-METABOLISM; INSULIN-RESISTANCE; TREATMENT SATISFACTION; CARDIOVASCULAR RISK; OBESE-PATIENTS; NORMAL-WEIGHT; HEART HEALTH; CPAP;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Although the association between obstructive sleep apnea (OSA) and type 2 diabetes mellitus (T2DM) is well-established, the impact of continuous positive airway pressure (CPAP) therapy on glycemic control or metabolic profiles in T2DM patients with OSA is unclear. The objective of this study was to investigate metabolism-related parameters and diabetes treatment satisfaction following CPAP therapy for OSA in overweight patients with T2DM or impaired glycemic tolerance. This retrospective study included 16 overweight patients treated with CPAP for OSA by comparison of laboratory and anthropometric data between baseline (3 months before initiation of CPAP treatment) and at 3-and 6-months post-treatment, and by psychometric scores of DM treatment satisfaction using the Diabetes Treatment Satisfaction Questionnaire (DTSQ). Significant reductions in body weight and waist circumference were observed after initiating CPAP therapy (both P<0.001). Mean glycosylated hemoglobin (HbA1c) level measured at 3 months after CPAP therapy was lower than the baseline assessment, and the mean HbA1c level at 6 months post-treatment was lower than that at 3 months post-treatment (both P<0.05). In addition, fasting and postprandial plasma glucose levels decreased significantly at 3 months after CPAP therapy, remaining stable at 6 months (P=0.009). Furthermore, significant decreases in fasting insulin level (P=0.037), postprandial insulin level (P<0.001), and triglyceride level (P=0.002) were observed following CPAP. Finally, satisfaction with diabetes treatment improved significantly following initiation of CPAP therapy (P<0.001). CPAP for OSA improved anthropomorphic measures as well as glycemic control, insulin sensitivity and diabetes treatment satisfaction in overweight patients with T2DM or abnormal glucose metabolism.
引用
收藏
页码:19858 / 19864
页数:7
相关论文
共 50 条
  • [21] Compliance with continuous positive airway pressure in Persian patients with obstructive sleep apnea
    Soltaninejad, Forogh
    Sadeghi, Ali
    Amra, Babak
    JOURNAL OF RESEARCH IN MEDICAL SCIENCES, 2017, 22
  • [22] Autotitration positive airway pressure therapy in patients with obstructive sleep apnea who are intolerant of fixed continuous positive airway pressure
    James M. Parish
    Bernie W. Miller
    Joseph G. Hentz
    Sleep and Breathing, 2008, 12 : 235 - 241
  • [23] The effect of continuous positive airway pressure on dyslipidemia in patients with obstructive sleep apnea
    Shehab-Eldin, Walid Abdelmohsen
    Elhabashy, Mahmoud
    EGYPTIAN JOURNAL OF BRONCHOLOGY, 2019, 13 (01) : 120 - 124
  • [24] Effect of zolpidem on the efficacy of continuous positive airway pressure as treatment for obstructive sleep apnea
    Berry, Richard B.
    Patel, Prakash B.
    SLEEP, 2006, 29 (08) : 1052 - 1056
  • [25] Evaluating the sleep quality of obstructive sleep apnea patients after continuous positive airway pressure treatment
    Hsu, Chien-Chang
    Wu, Jie-Han
    Chiu, Hou-Chang
    Lin, Chia-Mo
    COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (07) : 870 - 878
  • [26] Prediction of continuous positive airway pressure in obstructive sleep apnea
    José S. Loredo
    Charles Berry
    Richard A. Nelesen
    Joel E. Dimsdale
    Sleep and Breathing, 2007, 11 : 45 - 51
  • [27] Association of Positive Airway Pressure Adherence with Clinical Outcomes in Patients with Type 2 Diabetes and Obstructive Sleep Apnea
    Bouloukaki, Izolde
    Stathakis, George
    Moniaki, Violeta
    Mavroudi, Eleni
    Tsiligianni, Ioanna
    Schiza, Sophia
    DIAGNOSTICS, 2024, 14 (24)
  • [28] Effects of continuous positive airway pressure treatment on sleep architecture in adults with obstructive sleep apnea and type 2 diabetes
    Wilckens, Kristine A.
    Jeon, Bomin
    Morris, Jonna L.
    Buysse, Daniel J.
    Chasens, Eileen R.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [29] The effect of continuous positive airway pressure on dyslipidemia in patients with obstructive sleep apnea
    Walid Abdelmohsen Shehab-Eldin
    Mahmoud Elhabashy
    Egyptian Journal of Bronchology, 2019, 13 : 120 - 124
  • [30] Continuous positive airway pressure and type 2 diabetes mellitus
    Chakhtoura, Marlene
    Azar, Sami T.
    DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2012, 6 (03) : 176 - 179