Biomechanical Analysis of Zone 2 Flexor Tendon Repair With a Coupler Device Versus Locking Cruciate Core Suture

被引:8
|
作者
Irwin, Chetan S. [1 ]
Parks, Brent G. [1 ]
Means, Kenneth R., Jr. [1 ]
机构
[1] MedStar Union Mem Hosp, Curtis Natl Hand Ctr, 3333 North Calvert St,JPB 200, Baltimore, MD 21218 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2020年 / 45卷 / 09期
关键词
Biomechanical; suture devices; tendon repair; zone 2 flexor tendon; GAP FORMATION; ELONGATION; STRENGTH;
D O I
10.1016/j.jhsa.2020.02.015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose To compare flexor tendon repair strength and speed between a tendon coupler and a standard-core suture in a cadaver model. Methods In 5 matched-pair fresh cadaver hands, we cut the flexor digitorum profundus tendon of each finger in zone 2 and assigned 20 tendons to both the coupler and the suture groups. Coupler repair was with low-profile stainless steel staple plates in each tendon stump, bridged by polyethylene thread. Suture repair was performed using an 8-strand locking-cruciate technique with 4-0 looped, multifilament, polyamide suture. One surgeon with the Subspecialty Certificate in Surgery of the Hand performed all repairs. Via a load generator, each flexor digitorum profundus was loaded at 5 to 10 N and cycled through flexion just short of tip-to-palm and full extension at 0.2 Hz for 2,000 cycles to simulate 6 weeks of rehabilitation. We recorded repair gapping at predetermined cycle intervals. Our primary outcome was repair gapping at 2,000 cycles. Tendons that had not catastrophically failed by 2,000 cycles were loaded to failure on a servohydraulic frame at 1 mm/s. Results Tendon repair gapping was similar between coupled and sutured tendons at 2,000 cycles. Tendons repaired with the coupler had higher residual load to failure than sutured tendons. Mean coupler repair time was 4 times faster than suture repair. Conclusions Zone 2 flexor repair with a coupler withstood simulated early active motion in fresh cadavers. Residual load to failure and repair speed were better with the coupler. (Copyright (C) 2020 by the American Society for Surgery of the Hand. All rights reserved.)
引用
收藏
页码:878.e1 / 878.e6
页数:6
相关论文
共 50 条
  • [21] The Impact of Suture Caliber and Looped Configurations on the Suture-Tendon Interface in Zone II Flexor Tendon Repair
    Bernstein, Derek T.
    Alexander, Jamie J.
    Petersen, Nancy J.
    Lambert, Bradley S.
    Noble, Philip C.
    Netscher, David T.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (02): : 156.e1 - 156.e8
  • [22] FLEXOR TENDON REPAIR IN ZONE 2 USING A SIX-STRAND 'FIGURE OF EIGHT' SUTURE
    Al-Qattan, M. M.
    Al-Turaiki, T. M.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2009, 34E (03) : 322 - 328
  • [23] Flexor tendon repair using a new suture technique: a comparative in vitro biomechanical study
    Schaedel-Hoepfner, M.
    Windolf, J.
    Loegters, T. T.
    Hakimi, M.
    Celik, I.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2011, 37 (01) : 79 - 84
  • [24] Biomechanical Study of Asymmetric Flexor Tendon Repair Using 3 Different Suture Materials
    Teo, Shuo Ling
    Sarvananthan, Rajragavan
    Lim, Rebecca Qian Ru
    Wong, Yoke Rung
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2021, 26 (04): : 611 - 617
  • [25] A biomechanical study of pediatric flexor profundus tendon repair Comparing the tensile strengths of 3 suture techniques
    Al-Thunayan, Turki A.
    Al-Zahrani, Mohammed T.
    Hakeem, Ahmad A.
    Al-Zahrani, Fahad M.
    Al-Qattan, Mohammad M.
    SAUDI MEDICAL JOURNAL, 2016, 37 (09) : 957 - 962
  • [26] The Four-Strand Staggered Suture for Flexor Tendon Repair: In Vitro Biomechanical Study
    Corradi, Maurizio
    Bellan, Monia
    Frattini, Marco
    Concari, Galeazzo
    Tocco, Silvio
    Pogliacomi, Francesco
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (06): : 948 - 955
  • [27] Cyclic testing of six-strand suture techniques for zone 2 flexor tendon lacerations
    Kusano, Nozomu
    Zaegel, Melissa A.
    Silva, Matthew J.
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2024, 29 (05) : 1214 - 1219
  • [28] Biomechanical Analysis of Partial Flexor Tendon Lacerations in Zone II of Human Cadavers
    Manning, David W.
    Spiguel, Andre R.
    Mass, Daniel P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (01): : 11 - 18
  • [29] Work of Flexion Related to Different Suture Materials After Flexor Digitorum Profundus and Flexor Digitorum Superficialis Tendon Repair in Zone II: A Biomechanical Study
    Hwang, Michael D.
    Pettrone, Sarah
    Trumble, Thomas E.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2009, 34A (04): : 700 - 704
  • [30] Biomechanical Comparison of Transosseous Versus Suture Anchor Repair of the Subscapularis Tendon
    Wheeler, Daniel J.
    Garabekyan, Tigran
    Lugo, Roberto
    Buckley, Jenni M.
    Jones, Christopher
    Lotz, Marielena
    Lotz, Jeffery C.
    Ma, C. Benjamin
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2010, 26 (04): : 444 - 450