The Effect of Frequency on the Breakdown of XLPE Cable Insulation with Artificial Defects

被引:0
|
作者
Li, Weiwei [1 ]
Li, Jianying [1 ]
Zhou, Fusheng [1 ]
Wang, Shihang [1 ]
Li, Huan [1 ]
Li, Shengtao [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Shaanxi, Peoples R China
来源
2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP) | 2012年
关键词
Cross-linked polyethylene; breakdown; frequency; defect; ELECTRICAL TREES; PHYSICAL MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It is of great importance to assess the reliability of on-site testing for extruded insulation cables. In the present work, the effect of the applied field frequency on the breakdown performance of cross-linked polyethylene (XLPE) insulation was investigated. An inserted needle was embedded into a 10 kV commercial XLPE cable along the radial direction to simulate the real defects. The shape of the artificial defects was precisely controlled by a designed mold with a micrometer. Breakdown tests were conducted in transformer oil at room temperature using a frequency-tuned resonant test system and damped AC voltage system in the frequency range from 20 to 300 Hz. After breakdown measurements, specimens were cut into thin layers to investigate microstructure of their breakdown paths by an optical microscope. We found that the breakdown voltage of specimens with inserted needle was sensitive to the applied field frequency and voltage waveforms. The maximum breakdown voltages under variable frequency AC voltage locate at 25Hz and 240 Hz, while that under damped AC voltage locates around 180 Hz. It was found that DC ramp breakdown voltage is higher than impulses breakdown voltage, while ac breakdown voltage is the lowest. It was interesting to note that, different kinds of tree-like sub-paths appear on the flank of the main breakdown path of the specimen with the inserted needle at different frequencies. Frequency dependence of breakdown performance of XLPE cable with inserted needle defect was discussed.
引用
收藏
页码:375 / 378
页数:4
相关论文
共 50 条
  • [1] Breakdown mechanisms of XLPE cable with insulation defects
    Arachchige, Thanuja Gawasingha
    Narampanawa, Lakshitha
    Ekanayake, Chandima
    Ma, Hui
    2020 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (2020 IEEE CEIDP), 2020, : 71 - 74
  • [2] THE EFFECT OF MORPHOLOGY ON THE IMPULSE VOLTAGE BREAKDOWN IN XLPE CABLE INSULATION
    FUKUDA, T
    IRIE, S
    ASADA, Y
    MAEDA, M
    NAKAGAWA, H
    YAMADA, N
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (05): : 386 - 391
  • [3] Effect of defects and moisture on insulation characteristics of XLPE insulated cable
    Katsuta, Ginzo
    Toya, Atsushi
    Kanaoka, Mamoru
    Katakai, Shoshi
    Maruyama, Yoshio
    Muto, Hideji
    Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 1994, 114 (04): : 93 - 107
  • [4] EFFECT OF DEFECTS AND MOISTURE ON INSULATION CHARACTERISTICS OF XLPE INSULATED CABLE
    KATSUTA, G
    TOYA, A
    KANAOKA, M
    KATAKAI, S
    MARUYAMA, Y
    MUTO, H
    ELECTRICAL ENGINEERING IN JAPAN, 1994, 114 (04) : 93 - 107
  • [5] Frequency Dependence of Breakdown Performance of XLPE with Different Artificial Defects
    Li, Weiwei
    Li, Jianying
    Yin, Guilai
    Li, Shengtao
    Zhao, Jiankang
    Ouyang, Benhong
    Ohki, Yoshimichi
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2012, 19 (04) : 1351 - 1359
  • [6] LOCATION AND EXAMINATION OF DEFECTS IN XLPE CABLE INSULATION
    HAGEN, ST
    ILDSTAD, E
    SLETBAK, J
    FAREMO, H
    PROCEEDINGS OF THE 3RD INTERNATIONAL CONFERENCE ON CONDUCTION AND BREAKDOWN IN SOLID DIELECTRICS, 1989, : 569 - 573
  • [7] Effect of frequency on XLPE cable insulation at high electric field
    Bamji, SS
    Bulinksi, AT
    Cissé, L
    Tohyama, K
    2001 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2001, : 169 - 172
  • [8] Impulse breakdown superposed on ac voltage in XLPE cable insulation
    Murata, Y
    Katakai, S
    Kanaoka, M
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1996, 3 (03) : 361 - 365
  • [9] The influence of water in XLPE cable conductor on XLPE insulation breakdown voltage and partial discharge
    Nikolajevic, SV
    STojanovic, BB
    CONFERENCE RECORD OF THE 1996 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 1996, : 604 - 607
  • [10] Identification of XLPE cable insulation defects based on deep learning
    Tao Zhou
    Xiaozhong Zhu
    Haifei Yang
    Xuyang Yan
    Xuejun Jin
    Qingzhu Wan
    Global Energy Interconnection, 2023, 6 (01) : 36 - 49