Application of prospective ECG-triggered dual-source CT coronary angiography for infants and children with coronary artery aneurysms due to Kawasaki disease

被引:30
作者
Duan, Y. [2 ]
Wang, X. [1 ]
Cheng, Z.
Wu, D.
Wu, L.
机构
[1] Shandong Med Imaging Res Inst, Shandong Prov Key Lab Diag & Treatment Cardiocere, CT Dept, Jinan 250021, Shandong, Peoples R China
[2] Shandong Univ, Sch Med, Shandong Med Imaging Res Inst, Jinan 250100, Shandong, Peoples R China
关键词
CONGENITAL HEART-DISEASE; MAGNETIC-RESONANCE ANGIOGRAPHY; LONG-TERM MANAGEMENT; MULTIDETECTOR ROW CT; IMAGE QUALITY; FOLLOW-UP; CARDIAC-CATHETERIZATION; CARDIOVASCULAR-DISEASE; HEALTH-PROFESSIONALS; COMPUTED-TOMOGRAPHY;
D O I
10.1259/bjr/18174517
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this study was to prospectively evaluate the initial application and value of prospective electrocardiogram (ECG)-triggered dual-source CT coronary angiography (DSCTCA) in the diagnosis of infants and children with coronary artery aneurysms due to Kawasaki disease. Methods: 19 children [12 males; mean age 13.47 months, range 3 months to 5 years; mean heart rate 112 beats per minute (bpm), range 83-141 bpm] underwent prospective ECG-triggered DSCTCA with free breathing. Subjective image quality was assessed on a five-point scale (1, excellent; 5, non-diagnostic) by two blinded observers. The location, number and size of each aneurysm were observed and compared with those of transthoracic echocardiography (TTE) performed within 1 week. Interobserver agreement concerning the subjective image quality was evaluated with Cohen's kappa-test. Bland-Altman analysis was used to evaluate the agreement on measurements (diameter and length of aneurysms) between DSCTCA and TTE. The average effective dose required for DSCTCA was calculated for all children. Results: All interobserver agreement for subjective image quality assessment was excellent (kappa=0.87). The mean +/- standard deviation (SD) aneurysm diameter with DSCTCA was 0.76 +/- 0.36 cm and with TTE was 0.76 +/- 0.39 cm. The mean +/- SD aneurysm length with DSCTCA was 2.06 +/- 1.35 cm and with TTE was 2.00 +/- 1.22 cm. The Bland-Altman plot for agreement between DSCTCA and TTE measurements showed good agreement. The mean effective dose was 0.36 +/- 0.06 mSv. Conclusion: As an alternative diagnostic modality, prospective ECG-triggered DSCTCA with excellent image quality and low radiation exposure has been proved useful for diagnosing infants and children with coronary artery aneurysms due to Kawasaki disease. Advances in knowledge: Prospective ECG-triggered DSCTCA for infants and children allows rapid, accurate assessment of coronary aneurysms due to Kawasaki diseases, compared with TTE.
引用
收藏
页码:E1190 / E1197
页数:8
相关论文
共 45 条
[1]  
American Association of Physicists in Medicine, 2008, 95 AAPM
[2]   Visualization of coronary arteries in patients after childhood Kawasaki syndrome: value of multidetector CT and MR imaging in comparison to conventional coronary catheterization [J].
Arnold, Raoul ;
Ley, Sebastian ;
Ley-Zaporozhan, Julia ;
Eichhorn, Joachim ;
Schenk, Jens-Peter ;
Ulmer, Herbert ;
Kauczor, Hans-Ulrich .
PEDIATRIC RADIOLOGY, 2007, 37 (10) :998-1006
[3]   Effect of contrast material injection duration and rate on aortic peak time and peak enhancement at dynamic CT involving injection protocol with dose tailored to patient weight [J].
Awai, K ;
Hiraishi, K ;
Hori, S .
RADIOLOGY, 2004, 230 (01) :142-150
[4]   Coronary Anomalies Assessed by Whole-Heart Isotropic 3D Magnetic Resonance Imaging for Cardiac Morphology in Congenital Heart Disease [J].
Beerbaum, Philipp ;
Sarikouch, Samir ;
Laser, Kai-Thorsten ;
Greil, Gerald ;
Burchert, Wolfgang ;
Koerperich, Hermann .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) :320-327
[5]   Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease [J].
Ben Saad, Moez ;
Rohnean, Adela ;
Sigal-Cinqualbre, Anne ;
Adler, Ghazal ;
Paul, Jean-Francois .
PEDIATRIC RADIOLOGY, 2009, 39 (07) :668-676
[6]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[7]   Dual-source CT: effect of heart rate, heart rate variability, and calcification on image quality and diagnostic accuracy [J].
Brodoefel, Harald ;
Burgstahler, Christof ;
Tsiflikas, Ilias ;
Reimann, Anja ;
Schroeder, Stephen ;
Claussen, Claus D. ;
Heuschmid, Martin ;
Kopp, Andreas F. .
RADIOLOGY, 2008, 247 (02) :346-355
[8]   Diagnostic value of dual-source CT in Kawasaki disease [J].
Chao Bao-ting ;
Wang Xi-ming ;
Wu Le-bin ;
Chen Jie ;
Cheng Zhao-ping ;
Wu Da-wei ;
Duan Yan-hua .
CHINESE MEDICAL JOURNAL, 2010, 123 (06) :670-674
[9]   Coronary artery diameters in infants and children with congenital heart disease as determined by computed tomography [J].
Chen, Shyh-Jye ;
Lee, Wen-Jeng ;
Lin, Ming-Tai ;
Liu, Kao-Lang ;
Wang, Jou-Kou ;
Lue, Hung-Chi .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (11) :1696-1701
[10]   Low-dose prospective ECG-triggering dual-source CT angiography in infants and children with complex congenital heart disease: first experience [J].
Cheng, Zhaoping ;
Wang, Ximing ;
Duan, Yanhua ;
Wu, Lebin ;
Wu, Dawei ;
Chao, Baoting ;
Liu, Cheng ;
Xu, Zhuodong ;
Li, Hongxin ;
Liang, Fei ;
Xu, Jian ;
Chen, Jiuhong .
EUROPEAN RADIOLOGY, 2010, 20 (10) :2503-2511