High throughput analysis and capture of benzo[a]pyrene using supermacroporous poly(4-vinyl pyridine-co-divinyl benzene) cryogel matrix

被引:13
作者
Gupta, Ankur
Sarkar, Joyita
Kumar, Ashok [1 ]
机构
[1] Indian Inst Technol, Dept Biol Sci & Bioengn, Kanpur 208016, Uttar Pradesh, India
关键词
Anthracene; Benzo[a]pyrene; Chromatography; Cryogel; High throughput analysis; POLYCYCLIC AROMATIC-HYDROCARBONS; CHROMATOGRAPHY-MASS SPECTROMETRY; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; IMPRINTED POLYMER; AFFINITY; BENZO(A)PYRENE; ENRICHMENT; SEPARATION; PRODUCTS;
D O I
10.1016/j.chroma.2012.12.074
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A novel supermacroporous cryogel matrix, poly(4-vinyl pyridine-co-divinyl benzene) has been synthesized by free radical polymerization using 4-vinyl pyridine and divinyl benzene as monomers and poly(ethylene glycol) diacrylate as crosslinker. Hydrophobic property of such synthesized matrix allows capture of polyaromatic hydrocarbons like benzo[a]pyrene. The cryogel matrix produced is highly porous (porosity more than 80%) having large and interconnected pores in the range of 10-100 mu m that allows easy passage of particulate matter and viscous liquids. The newly synthesized cryogel minicolumns (0.5 ml; 0.9 cm dia. x 1.2 cm height) were used to develop a high throughput analysis system in a miniaturized platform (open ended 96-well microtitre plate). The performance of the cryogel columns in 96-well microtitre plate was reproducible in different wells having approximately 72% binding. This system is drainage- and leakage- protected and can be used for the easy, fast and parallel analysis of many samples. The 96-well format also allows efficient analysis of benzo[a]pyrene in the spiked sample. The cryogel matrix was then used for column chromatography, which showed that the matrix has a binding capacity of 2 mu g per ml of matrix for benzo[a]pyrene, thus providing a system for remediation/separation of benzo[a]pyrene. The chromatographic column could bind and partially separate the spiked mixture of benzo[a]pyrene and anthracene. (c) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:16 / 21
页数:6
相关论文
共 36 条
[11]   Enrichment of benzo[a]pyrene in smoked food products and determination by high-performance liquid chromatography fluorescence detection [J].
Falcon, MG ;
Amigo, SG ;
Yusty, MAL ;
Villaizan, MJLD ;
Lozano, JS .
JOURNAL OF CHROMATOGRAPHY A, 1996, 753 (02) :207-215
[12]   High throughput processing of particulate-containing samples using supermacroporous elastic monoliths in microtiter (multiwell) plate format [J].
Galaev, IY ;
Dainiak, MB ;
Plieva, FM ;
Hatti-Kaul, R ;
Mattiasson, B .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1065 (02) :169-175
[13]  
He L., 2011, COLLOID SURFACE B, V273, P87
[14]   Development of Molecular Imprinted Polymer for Selective Adsorption of Benz[a]pyrene Among Airborne Polycyclic Aromatic Hydrocarbon Compounds [J].
Ho, Wei-Lun ;
Liu, Yu-Yin ;
Lin, Ta-Chang .
ENVIRONMENTAL ENGINEERING SCIENCE, 2011, 28 (06) :421-434
[15]   HYDROPHOBIC-INTERACTION CHROMATOGRAPHY AND ANION-EXCHANGE CHROMATOGRAPHY IN THE PRESENCE OF ACETONITRILE - A 2-STEP PURIFICATION METHOD FOR HUMAN-PROLACTIN [J].
HODGKINSON, SC ;
LOWRY, PJ .
BIOCHEMICAL JOURNAL, 1981, 199 (03) :619-627
[16]   Designing Supermacroporous Cryogels Based on Polyacrylonitrile and a Polyacrylamide-Chitosan Semi-interpenetrating Network [J].
Jain, Era ;
Kumar, Ashok .
JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION, 2009, 20 (7-8) :877-902
[17]  
Koc I., 2011, J HAZARD MATER, V192, P1819
[18]   Highly sensitive determination of polycyclic aromatic hydrocarbons in ambient air dust by gas chromatography-mass spectrometry after molecularly imprinted polymer extraction [J].
Krupadam, Reddithota J. ;
Bhagat, Bhagyashree ;
Khan, Muntazir S. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 397 (07) :3097-3106
[19]   Cell separation using cryogel-based affinity chromatography [J].
Kumar, Ashok ;
Srivastava, Akshay .
NATURE PROTOCOLS, 2010, 5 (11) :1737-1747
[20]   Benzo[a]pyrene imprinted polymers: synthesis, characterization and SPE application in water and coffee samples [J].
Lai, JP ;
Niessner, R ;
Knopp, D .
ANALYTICA CHIMICA ACTA, 2004, 522 (02) :137-144