In vitro studies of gas bubble formation by mechanical heart valves

被引:0
|
作者
Biancucci, BA
Deutsch, S
Geselowitz, DB
Tarbell, JM
机构
[1] Penn State Univ, Dept Bioengn, University Pk, PA 16802 USA
[2] Penn State Univ, Appl Res Lab, University Pk, PA 16802 USA
来源
JOURNAL OF HEART VALVE DISEASE | 1999年 / 8卷 / 02期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Recent clinical research using transcranial Doppler ultrasonography has shown the presence of emboli in the cranial circulation of some mechanical heart valve patients. Due to the high-intensity signals produced by these emboli, it has been suggested that they are small gas bubbles. Meanwhile, transesophageal echocardiography of mechanical heart valve patients has shown images of bright, mobile particles (also considered to be gas bubbles) near the valve. Motivated by these reports, a series of in vitro studies was performed to investigate the relationship between dissolved gas concentration and the incidence of bubble formation after valve closure. Methods: A mock circulatory loop was used to study a Medtronic Hall tilting disc valve in the mitral position of the Penn State Electrical Ventricular Assist Device (EVAD). The valve was videotaped as it operated in saline with various levels of dissolved CO2. A Doppler ultrasound probe served as a bubble detector on the outflow side of the EVAD. Measurements of vaporous cavitation intensity with a high-fidelity pressure transducer were also made. Similar experiments were then performed in porcine blood, using an imaging ultrasound transducer to detect bubbles. Results: Bubbles were seen moving off the valve in the retrograde direction just after closure. The ultrasound probe detected these bubbles downstream, indicating a bubble lifetime on the order of seconds. It was observed with high-speed video that bubble formation and cavitation are separate events and occur at different times during valve closure. Bubbles were more likely to be observed when CO2 levels were higher. Experiments in blood provided images of bubbles near the valve, predominantly at higher CO2 levels and high valve loading conditions. Conclusions: These results show that stable gas bubbles can form during mechanical heart valve operation. The bubbles likely form from the combined effects of gaseous nuclei formed by cavitation, low-pressure regions associated with regurgitant flow, and the presence of CO2, a highly soluble gas.
引用
收藏
页码:186 / 196
页数:11
相关论文
共 50 条
  • [1] Bubble formation on St. Jude Medical Mechanical Heart Valves: An in-vitro study
    Milo, S
    Gutfinger, C
    Chu, GYC
    Gharib, M
    JOURNAL OF HEART VALVE DISEASE, 2003, 12 (03): : 406 - 410
  • [2] Observation and quantification of gas bubble formation on a mechanical heart valve
    Lin, HY
    Bianccucci, BA
    Deutsch, S
    Fontaine, AA
    Tarbell, JM
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (04): : 304 - 309
  • [3] In-Vitro Detection of Thrombotic Formation on Bileaflet Mechanical Heart Valves
    Susin, Francesca Maria
    Tarzia, Vincenzo
    Bottio, Tomaso
    Pengo, Vittorio
    Bagno, Andrea
    Gerosa, Gino
    JOURNAL OF HEART VALVE DISEASE, 2011, 20 (04): : 378 - 386
  • [4] Mitral mechanical heart valves: in vitro studies of their closure, vortex and microbubble formation with possible medical implications
    Milo, S
    Rambod, E
    Gutfinger, C
    Gharib, M
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2003, 24 (03) : 364 - 370
  • [5] Flow induced platelet activation in mechanical heart valves -: in vitro studies
    Yin, W
    Bluestein, D
    Jesty, J
    Perrotta, P
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1599 - 1600
  • [6] In vitro thrombogenicity investigation for mechanical heart valves
    不详
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (09): : 867 - 867
  • [7] Can mechanical heart valves perform similarly to tissue valves? An in vitro study
    Goode, Dylan
    Scotten, Lawrence
    Siegel, Rolland
    Mohammadi, Hadi
    JOURNAL OF BIOMECHANICS, 2024, 174
  • [8] Imaging of pannus formation in patients with mechanical heart valves
    Gunduz, Sabahattin
    Ozkan, Mehmet
    Yesin, Mahmut
    WORLD JOURNAL OF CARDIOLOGY, 2015, 7 (11): : 822 - +
  • [9] A physical model describing the mechanism for formation of gas microbubbles in patients with mitral mechanical heart valves
    Rambod, E
    Beizaie, M
    Shusser, M
    Milo, S
    Gharib, M
    ANNALS OF BIOMEDICAL ENGINEERING, 1999, 27 (06) : 774 - 792
  • [10] A Physical Model Describing the Mechanism for Formation of Gas Microbubbles in Patients with Mitral Mechanical Heart Valves
    Edmond Rambod
    Masoud Beizaie
    Michael Shusser
    Simcha Milo
    Morteza Gharib
    Annals of Biomedical Engineering, 1999, 27 : 774 - 792