Determination of enantiomeric impurity in besifloxacin hydrochloride by chiral high-performance liquid chromatography with precolumn derivatization

被引:20
作者
Wang, Zhangting [1 ]
Wang, Shengjia [1 ]
Zhu, Feng [2 ]
Chen, Zaixin [2 ]
Yu, Lushan [1 ]
Zeng, Su [1 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Hangzhou 310058, Zhejiang, Peoples R China
[2] Jiangsu Yabang Pharmaceut Grp Co Ltd, R&D Ctr, Jintan, Jiangsu, Peoples R China
关键词
besifloxacin hydrochloride; enantiomer; precolumn derivatization; chiral; enantiomeric impurity; STATIONARY-PHASE; CROWN-ETHER; FLUOROQUINOLONE ANTIBACTERIALS; SEPARATION; GEMIFLOXACIN; OFLOXACIN; HPLC;
D O I
10.1002/chir.22042
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Besifloxacin hydrochloride is a novel chiral broad-spectrum fluoroquinolone developed for the treatment of bacterial conjunctivitis. R-besifloxacin hydrochloride is used in clinics as a consequence of its higher antibacterial activity. To establish an enantiomeric impurity determination method, some chiral stationary phases (CSPs) were screened. Besifloxacin enantiomers can be separated to a certain extent on Chiral CD-Ph (Shiseido Co., Ltd., Japan), Chiral AGP, and Crownpak CR (+) (Daicel Chemical IND., Ltd., Japan). However, the selectivity and sensitivity were both unsatisfactory on these three CSPs. Therefore, Chiral AGP, Chiral CD-Ph, and Crownpak CR (+) were not used in the enantiomeric impurity determination of besifloxacin hydrochloride. The separation of enantiomers of besifloxacin was further performed using a precolumn derivatization chiral high-performance liquid chromatography method. 2,3,4,6-Tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate was used as the derivatization reagent. Besifloxacin enantiomer derivates were well separated on a C18 column (250 x 4.6?mm, 5 mu m) with a mobile phase that consisted of methanol-KH2PO4 buffer solution (20?mM; pH?3.0) (50:50, v/v). Selectivity, sensitivity, linearity, accuracy, precision, stability, and robustness of this method were all satisfied with the method validation requirement. The method was suitable for the quality control of enantiomeric impurity in besifloxacin hydrochloride. Chirality 24:526531, 2012. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:526 / 531
页数:6
相关论文
共 50 条
[21]   Chiral separation and quantitation of dorzolamide hydrochloride enantiomers by high-performance liquid chromatography [J].
Shamsipur, Mojtaba ;
Heydari, Rouhollah ;
Jamasbi, Elahe Sadat ;
Abdollahpour, Assem .
JOURNAL OF SEPARATION SCIENCE, 2010, 33 (15) :2328-2333
[22]   Analysis of Organic Impurities of Besifloxacin Hydrochloride by High-Performance Liquid Chromatography with Isocratic and Gradient Elution [J].
Manoel, Joanna Wittckind ;
Alves Giordani, Camila Ferrazza ;
Bueno, Livia Maronesi ;
Campanharo, Sarah Chagas ;
Sherman Schapoval, Elfrides Eva ;
Garcia, Cassia Virginia ;
Steppe, Martin ;
Volpato, Nadia Maria .
CURRENT PHARMACEUTICAL ANALYSIS, 2021, 17 (04) :564-572
[23]   Enantiomeric separation of asymmetric triacylglycerol by recycle high-performance liquid chromatography with chiral column [J].
Nagai, Toshiharu ;
Mizobe, Hoyo ;
Otake, Ikuko ;
Ichioka, Kenji ;
Kojima, Koichi ;
Matsumoto, Yumiko ;
Gotoh, Naohiro ;
Kuroda, Ikuma ;
Wada, Shun .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (20) :2880-2886
[24]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR DIRECT AND INDIRECT ENANTIOMERIC SEPARATIONS OF CHIRAL DRUGS [J].
WITTE, DT .
PHARMACY WORLD & SCIENCE, 1993, 15 (06) :283-284
[25]   DETERMINATION OF LIPASE ACTIVITY BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PRECOLUMN FLUORESCENCE DERIVATIZATION USING 9-BROMOMETHYLACRIDINE [J].
TSUZUKI, W ;
SHIMURA, S ;
AKASAKA, K ;
SUZUKI, T .
ANALYTICAL SCIENCES, 1991, 7 (02) :253-256
[26]   DETERMINATION OF JOSAMYCIN RESIDUES IN PORCINE TISSUES USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PRECOLUMN DERIVATIZATION AND SPECTROFLUOROMETRIC DETECTION [J].
LEROY, P ;
DECOLIN, D ;
NICOLAS, A ;
ARCHIMBAULT, P .
ANALYST, 1994, 119 (12) :2743-2747
[27]   Determination of Pioglitazone Hydrochloride in Tablets by High-Performance Liquid Chromatography [J].
Saber, A. L. .
PAKISTAN JOURNAL OF ANALYTICAL & ENVIRONMENTAL CHEMISTRY, 2008, 9 (02)
[28]   Determination of the enantiomeric impurity in S-(-)pantoprazole using high performance liquid chromatography with sulfobutylether-beta-cyclodextrin as chiral additive [J].
Guan, Jin ;
Yang, Jing ;
Bi, Yujin ;
Shi, Shuang ;
Yan, Feng ;
Li, Famei .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (02) :288-293
[29]   DETERMINATION OF THROMBOXANE-B2 BY NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER PRECOLUMN DERIVATIZATION WITH FLUORESCENT REAGENTS [J].
BENGUEDDOUR, R ;
MATT, M ;
NICOLAS, A ;
DONNER, M ;
STOLTZ, JF .
ANALYTICAL LETTERS, 1993, 26 (03) :429-443
[30]   Simultaneous Determination of Glutathione, Cysteine, Homocysteine, and Cysteinylglycine in Biological Fluids by Ion-Pairing High-Performance Liquid Chromatography Coupled with Precolumn Derivatization [J].
Zhang, Wenbing ;
Li, Pingliang ;
Geng, Qianqian ;
Duan, Yongheng ;
Guo, Mingcheng ;
Cao, Yongsong .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2014, 62 (25) :5845-5852