Determination of enantiomeric impurity in besifloxacin hydrochloride by chiral high-performance liquid chromatography with precolumn derivatization

被引:22
作者
Wang, Zhangting [1 ]
Wang, Shengjia [1 ]
Zhu, Feng [2 ]
Chen, Zaixin [2 ]
Yu, Lushan [1 ]
Zeng, Su [1 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Hangzhou 310058, Zhejiang, Peoples R China
[2] Jiangsu Yabang Pharmaceut Grp Co Ltd, R&D Ctr, Jintan, Jiangsu, Peoples R China
关键词
besifloxacin hydrochloride; enantiomer; precolumn derivatization; chiral; enantiomeric impurity; STATIONARY-PHASE; CROWN-ETHER; FLUOROQUINOLONE ANTIBACTERIALS; SEPARATION; GEMIFLOXACIN; OFLOXACIN; HPLC;
D O I
10.1002/chir.22042
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Besifloxacin hydrochloride is a novel chiral broad-spectrum fluoroquinolone developed for the treatment of bacterial conjunctivitis. R-besifloxacin hydrochloride is used in clinics as a consequence of its higher antibacterial activity. To establish an enantiomeric impurity determination method, some chiral stationary phases (CSPs) were screened. Besifloxacin enantiomers can be separated to a certain extent on Chiral CD-Ph (Shiseido Co., Ltd., Japan), Chiral AGP, and Crownpak CR (+) (Daicel Chemical IND., Ltd., Japan). However, the selectivity and sensitivity were both unsatisfactory on these three CSPs. Therefore, Chiral AGP, Chiral CD-Ph, and Crownpak CR (+) were not used in the enantiomeric impurity determination of besifloxacin hydrochloride. The separation of enantiomers of besifloxacin was further performed using a precolumn derivatization chiral high-performance liquid chromatography method. 2,3,4,6-Tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate was used as the derivatization reagent. Besifloxacin enantiomer derivates were well separated on a C18 column (250 x 4.6?mm, 5 mu m) with a mobile phase that consisted of methanol-KH2PO4 buffer solution (20?mM; pH?3.0) (50:50, v/v). Selectivity, sensitivity, linearity, accuracy, precision, stability, and robustness of this method were all satisfied with the method validation requirement. The method was suitable for the quality control of enantiomeric impurity in besifloxacin hydrochloride. Chirality 24:526531, 2012. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:526 / 531
页数:6
相关论文
共 12 条
[1]   DISTRIBUTION BEHAVIOR OF SOME DRUG ENANTIOMERS IN AN AQUEOUS 2-PHASE SYSTEM USING COUNTERCURRENT EXTRACTION WITH PROTEIN [J].
ARAI, T ;
KURODA, H .
CHROMATOGRAPHIA, 1991, 32 (1-2) :56-60
[2]   Besifloxacin: A Topical Fluoroquinolone for the Treatment of Bacterial Conjunctivitis [J].
Chang, Mei H. ;
Fung, Horatio B. .
CLINICAL THERAPEUTICS, 2010, 32 (03) :454-471
[3]   HPLC of fluoroquinolone antibacterials using chiral stationary phase based on enantiomeric (3,3′-diphenyl-1,1′-binaphthyl)-20-crown-6 [J].
Choi, Hee Jung ;
Cho, Hwan Sun ;
Han, Sang Cheol ;
Hyun, Myung Ho .
JOURNAL OF SEPARATION SCIENCE, 2009, 32 (04) :536-541
[4]  
Comstock TL, 2010, CLIN OPHTHALMOL, V4, P215
[5]  
*FDA, 1992, FDA POL STAT DEV NEW
[6]   Liquid chromatographic separation of the enantiomers of fluoroquinolone antibacterials on a chiral stationary phase based on a chiral crown ether [J].
Hyun, MH ;
Han, SC .
JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS, 2002, 54 (1-3) :235-243
[7]   Separation of the stereoisomers of racemic fluoroquinolone antibacterial agents on a crown-ether-based chiral HPLC stationary phase [J].
Hyun, MH ;
Han, SC ;
Jin, JS ;
Lee, W .
CHROMATOGRAPHIA, 2000, 52 (7-8) :473-476
[8]   Liquid chromatographic resolution of gemifloxacin mesylate on a chiral stationary phase derived from crown ether [J].
Hyun, MH ;
Han, SC ;
Cho, YJ ;
Jin, JS ;
Lee, W .
BIOMEDICAL CHROMATOGRAPHY, 2002, 16 (05) :356-360
[9]  
INTERNATIONAL CONFERENCE on HARMONISATION. ICH, 1996, GUID IND Q2B VAL AN
[10]   Direct liquid chromatographic enantiomer separation of new fluoroquinolones including gemifloxacin [J].
Lee, W ;
Hong, CY .
JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (02) :113-120