Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of leucine in biological and pharmaceutical samples

被引:31
|
作者
Rezaei, B. [1 ]
Zare, Z. Mirahmadi [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan, IR, Iran
关键词
cyclic voltammetry; electrocatalytic; leucine; modified glassy carbon electrode; multiwall carbon nanotubes;
D O I
10.1080/00032710802238036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and highly sensitive method is described for voltammetric determination of leucine in blood and urine samples; namely, a glassy carbon electrode with an effective method is modified with multiwall carbon nanotubes (MWNTs). The cyclic voltammetric results indicated that MWNTs remarkably enhanced electrocatalytic activity toward the oxidation of leucine. Under the optimum condition the calibration curve was linear in the concentration range 9.0 x 10(-6) 1.5 x 10(-3) mol L-1, with the detection limit of 3.0 x 10(-6) mol L-1 and a relative standard deviation (RSD%) lower than 3.0% (n = 5). Also, some kinetic parameters were determined and a multistep mechanism for oxidation of leucine was proposed.
引用
收藏
页码:2267 / 2286
页数:20
相关论文
共 50 条
  • [21] Voltammetric determination of paracetamol in pharmaceutical tablet samples using anthraquinone modified carbon paste electrode
    Amare, Meareg
    Teklay, Welday
    COGENT CHEMISTRY, 2019, 5 (01):
  • [22] Diaminoanthraquinone polymer modified glassy carbon electrode for the voltammetric determination of imidacloprid
    Soman, Sithara
    Ramakrishnan, Kala
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2024, 54 (12) : 2831 - 2843
  • [23] VoltammetricDetermination of Glutathionein Pharmaceutical and Biological Samples Using Multiwall Carbon Nanotubes Paste Electrode in the Presence of Rutin as a Mediator
    Keyvanfard, Mohsen
    Jalilian, Zeynab
    Karimi-Maleh, Hassan
    Alizad, Khadijeh
    IRANIAN JOURNAL OF PHARMACEUTICAL RESEARCH, 2020, 19 (02): : 251 - 258
  • [24] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Suling Yang
    Ran Yang
    Gang Li
    Jianjun Li
    Lingbo Qu
    Journal of Chemical Sciences, 2010, 122 : 919 - 926
  • [25] Voltammetric determination of theophylline at a Nafion/multi-wall carbon nanotubes composite film-modified glassy carbon electrode
    Yang, Suling
    Yang, Ran
    Li, Gang
    Li, Jianjun
    Qu, Lingbo
    JOURNAL OF CHEMICAL SCIENCES, 2010, 122 (06) : 919 - 926
  • [26] Multiwall carbon nanotube paste electrode as a sensor for sensitive determination of deferasirox in the presence of uric acid: application for the analysis of pharmaceutical and biological samples
    Parvizi Fard, Golnaz
    Emamali Sabzi, Reza
    TURKISH JOURNAL OF CHEMISTRY, 2018, 42 (02) : 493 - 504
  • [27] Electrochemical oxidation behavior of hydrochlorothiazide on a glassy carbon electrode and its voltammetric determination in pharmaceutical formulations and biological fluids
    Alghamdi, Ali F.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (03) : 363 - 369
  • [28] Voltammetric reduction of a 4-nitroimidazole derivative on a multiwalled carbon nanotubes modified glassy carbon electrode
    Jara-Ulloa, P.
    Bollo, S.
    Nunez-Vergara, L. J.
    Squella, J. A.
    ELECTROANALYSIS, 2008, 20 (13) : 1470 - 1474
  • [29] Voltammetric determination of chlorogenic acid in pharmaceutical products using poly(aminosulfonic acid) modified glassy carbon electrode
    Chao, Mingyong
    Ma, Xinying
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2014, 22 (04) : 512 - 519
  • [30] Voltammetric determination of bisoprolol on a glassy carbon electrode modified by poly(arylene phthalide)
    Zil'berg, R. A.
    Yarkaeva, Yu. A.
    Sidel'nikov, A. V.
    Maistrenko, V. N.
    Kraikin, V. A.
    Gileva, N. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2016, 71 (09) : 926 - 931