Modified glassy carbon electrode with multiwall carbon nanotubes as a voltammetric sensor for determination of leucine in biological and pharmaceutical samples

被引:31
作者
Rezaei, B. [1 ]
Zare, Z. Mirahmadi [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan, IR, Iran
关键词
cyclic voltammetry; electrocatalytic; leucine; modified glassy carbon electrode; multiwall carbon nanotubes;
D O I
10.1080/00032710802238036
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple and highly sensitive method is described for voltammetric determination of leucine in blood and urine samples; namely, a glassy carbon electrode with an effective method is modified with multiwall carbon nanotubes (MWNTs). The cyclic voltammetric results indicated that MWNTs remarkably enhanced electrocatalytic activity toward the oxidation of leucine. Under the optimum condition the calibration curve was linear in the concentration range 9.0 x 10(-6) 1.5 x 10(-3) mol L-1, with the detection limit of 3.0 x 10(-6) mol L-1 and a relative standard deviation (RSD%) lower than 3.0% (n = 5). Also, some kinetic parameters were determined and a multistep mechanism for oxidation of leucine was proposed.
引用
收藏
页码:2267 / 2286
页数:20
相关论文
共 54 条
[1]  
AGUIARA M, 2005, SENSITIVE CAPILLARY
[2]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[3]   Partial characterization of peptides from red wines. Changes during malolactic fermentation and ageing with lees [J].
Alcaide-Hidalgo, J. M. ;
Moreno-Arribas, M. V. ;
Polo, M. C. ;
Pueyo, E. .
FOOD CHEMISTRY, 2008, 107 (02) :622-630
[4]   CELL-CYCLE ANALYSIS OF AMOUNT AND DISTRIBUTION OF NUCLEAR-DNA TOPOISOMERASE-I AS DETERMINED BY FLUORESCENCE DIGITAL IMAGING MICROSCOPY [J].
BAKER, SD ;
WADKINS, RM ;
STEWART, CF ;
BECK, WT ;
DANKS, MK .
CYTOMETRY, 1995, 19 (02) :134-145
[5]   Exploring the electrocatalytic sites of carbon nanotubes for NADH detection: an edge plane pyrolytic graphite electrode study [J].
Banks, CE ;
Compton, RG .
ANALYST, 2005, 130 (09) :1232-1239
[6]   Investigation of modified basal plane pyrolytic graphite electrodes: definitive evidence for the electrocatalytic properties of the ends of carbon nanotubes [J].
Banks, CE ;
Moore, RR ;
Davies, TJ ;
Compton, RG .
CHEMICAL COMMUNICATIONS, 2004, (16) :1804-1805
[7]   Separation of leucine and isoleucine by electrospray ionization-high field asymmetric waveform ion mobility spectrometry-mass spectrometry [J].
Barnett, DA ;
Ells, B ;
Guevremont, R ;
Purves, RW .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) :1279-1284
[8]   An integrated amperometry waveform for the direct, sensitive detection of amino acids and amino sugars following anion-exchange chromatography [J].
Clarke, AP ;
Jandik, P ;
Rocklin, RD ;
Liu, Y ;
Avdalovic, N .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2774-2781
[9]   Electrochemical detection of amino acids at carbon nanotube and nickel-carbon nanotube modified electrodes [J].
Deo, RP ;
Lawrence, NS ;
Wang, J .
ANALYST, 2004, 129 (11) :1076-1081
[10]  
*DION CORP, 2003, 130 DION CORP