National primary standard for the unit of air kerma, air kerma rate, exposure, exposure rate, and x- and gamma-ray energy flux

被引:2
作者
Oborin, A. V. [1 ]
Villevalde, A. Yu. [1 ]
Trofimchuk, S. G. [1 ]
机构
[1] Mendeleev All Russia Res Inst Metrol VNIIM, St Petersburg, Russia
关键词
standard; air kerma; exposure; energy flux (power); x-rays and gamma-rays; key comparisons; RUSSIAN-FEDERATION; VNIIM; BIPM;
D O I
10.1007/s11018-012-0050-8
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The current state of the national primary standard GET 8-2011 for the units of air kerma, exposure, their rates, and energy flux (power) in x- and gamma-radiation, which was revised in 2007-2011, is examined. The structure of the standard, and its operating principles and metrological characteristics, are described.
引用
收藏
页码:849 / 857
页数:9
相关论文
共 20 条
  • [11] Feasibility study on determining the conventional true value of gamma-ray air kerma in a minitype reference radiation
    Liu, Yi-Xin
    Wei, Biao
    Xu, Yang
    He, Meng
    Zhuo, Ren-Hong
    Wen, De-Zhi
    Ding, Da-Jie
    Mao, Ben-Jiang
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (06)
  • [12] Feasibility study on determining the conventional true value of gamma-ray air kerma in a minitype reference radiation
    Yi-Xin Liu
    Biao Wei
    Yang Xu
    Meng He
    Ren-Hong Zhuo
    De-Zhi Wen
    Da-Jie Ding
    Ben-Jiang Mao
    Nuclear Science and Techniques, 2017, 28
  • [13] Establishment of air kerma reference standard for low dose rate Cs-137 brachytherapy sources
    Sharma, Sunil Dutt
    Kumar, Sudhir
    Srinivasan, P.
    Chourasiya, G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 275 - 285
  • [14] Comparison of the NIST and BIPM medium-energy X-ray air-kerma measurements
    Burns, DT
    Lamperti, P
    O'Brien, M
    Boutillon, M
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2003, 108 (05) : 383 - 389
  • [15] Spatial distribution of air kerma rate and impact of accelerating voltage on the quality of an ultra soft X-ray beam generated by a cold cathode tube in air
    Ounoughi, N.
    Mavon, C.
    Belafrites, A.
    Fromm, M.
    RADIATION MEASUREMENTS, 2015, 80 : 23 - 28
  • [16] Comparison Between the NIST and the KEBS for the Determination of Air Kerma Calibration Coefficients for Narrow X-Ray Spectra and 137Cs Gamma-Ray Beams
    O'Brien, Michelle
    Minniti, Ronaldo
    Masinza, Stanslaus Alwyn
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2010, 115 (01) : 7 - 13
  • [17] Comparison of the NIST and BIPM air-kerma standards for measurements in the low-energy x-ray range
    Burns, DT
    Lamperti, P
    O'Brien, M
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 1999, 104 (02) : 135 - 140
  • [18] Radiographic and fluoroscopic X-ray systems: Quality control of the X-ray tube and automatic exposure control using theoretical spectra to determine air kerma and dose to a homogenous phantom
    Konst, Bente
    Notthellen, Jacob
    Bilet, Ellinor
    Bath, Magnus
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08): : 204 - 218
  • [19] A conversion method of air kerma from the primary, scatter, and leakage radiations to effective dose for calculating x-ray shielding barriers in mammography
    Kharrati, H
    MEDICAL PHYSICS, 2005, 32 (05) : 1367 - 1374
  • [20] Evaluation of mean conversion coefficients from air-kerma to H*(10) using secondary and transmitted x-ray spectra in the diagnostic radiology energy range
    Gonzales, A. H. Lopez
    Santos, J. C.
    Mariano, L.
    Tomal, A.
    Costa, P. R.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2016, 36 (04) : 842 - 857