Quantification of stato-kinetic dissociation by semi-automated perimetry

被引:15
|
作者
Schiller, J
Paetzold, J
Vonthein, R
Hart, WM
Kurtenbach, A
Schiefer, U
机构
[1] Univ Eye Hosp Tuebingen, Dept 2, D-72076 Tubingen, Germany
[2] Univ Tubingen, Dept Med Biometry, D-72070 Tubingen, Germany
[3] Washington Univ, Sch Med, St Louis, MO 63110 USA
关键词
semi-automated perimetry; stato-kinetic dissociation; reaction time;
D O I
10.1016/j.visres.2005.08.026
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The difference in threshold sensitivities that are found when examining the visual field (VF) with static versus kinetic perimetric methods is called stato-kinetic dissociation (SKID). In this pilot study, we describe a semi-automated procedure for quantifying SKD. Fifteen patients with VF defects were examined with kinetic and static perimetry. SKID values were defined as positive when the static scotoma was larger than the kinetic one. We found significant local variations of SKD along scotoma borders with the individual reaction time as an important criterion when determining kinetic thresholds. There was a verifiable SKID in all patients with locally negative values in eight subjects. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:117 / 128
页数:12
相关论文
共 50 条
  • [1] Evaluation of stato-kinetic dissociation using examiner-independent automated perimetric techniques
    Schiller, J
    Paetzold, J
    Vonthein, R
    Schiefer, U
    PERIMETRY UPDATE 2002/2003, 2004, : 75 - 81
  • [2] Automated assessment of stato-kinetic dissociation (SKD) in advanced visual field defects.
    Schiller, J
    Schiefer, U
    Paetzold, J
    Benda, N
    Vonthein, R
    Dietz, K
    Dietrich, TJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S295 - S295
  • [3] AUTOMATED AND SEMI-AUTOMATED PERIMETRY
    PRADINES, F
    DELBOSC, B
    ROYER, J
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 1985, 8 (02): : 173 - 185
  • [4] Quantification of the Visual Field Loss in Retinitis Pigmentosa Using Semi-Automated Kinetic Perimetry
    Nowomiejska, Katarzyna
    Brzozowska, Agnieszka
    Koss, Michael J.
    Weleber, Richard G.
    Schiefer, Ulrich
    Rejdak, Konrad
    Juenemann, Anselm G.
    Maciejewski, Ryszard
    Rejdak, Robert
    CURRENT EYE RESEARCH, 2016, 41 (07) : 993 - 998
  • [5] Realization of semi-automated kinetic perimetry with the interzeag octopus 101 instrument
    Schiefer, U
    Rauscher, S
    Hermann, A
    Nowomiejska, K
    Paetzold, J
    Schiller, J
    PERIMETRY UPDATE 2002/2003, 2004, : 233 - 238
  • [6] Evaluating semi-automated kinetic perimetry in persons with idiopathic intracranial hypertension
    Hickman, Simon J.
    Givens, Lucy
    Jefferis, Joanna M.
    Pepper, Irene M.
    Rhodes, Martin J.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2025,
  • [7] Variability in Isopter Position and Fatigue during Semi-Automated Kinetic Perimetry
    Nowomiejska, Katarzyna
    Brzozowska, Agnieszka
    Zarnowski, Tomasz
    Rejdak, Robert
    Weleber, Richard G.
    Schiefer, Ulrich
    OPHTHALMOLOGICA, 2012, 227 (03) : 166 - 172
  • [8] Age dependence of normative values in semi-automated kinetic perimetry (SKP)
    Schiefer, U
    Rauscher, S
    Hermann, A
    Nowomiejska, KE
    Sadowski, B
    Vonthein, R
    Paetzold, J
    Schiller, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U318 - U318
  • [9] Comparison of static automated perimetry and semi-automated kinetic perimetry in patients with bilateral visible optic nerve head drusen
    Nowomiejska, Katarzyna
    Rejdak, Robert
    Zagorski, Zbigniew
    Zarnowski, Tomasz
    ACTA OPHTHALMOLOGICA, 2009, 87 (07) : 801 - 805
  • [10] Test-Retest Variability for Semi-Automated Kinetic Perimetry and GATE Static Perimetry in Retinitis Pigmentosa
    Peters, Dawn
    Chegarnov, Elvira
    Erker, Laura
    Pennesi, Mark
    Weleber, Richard
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)