X-ray harmonics rejection on third-generation synchrotron sources using compound refractive lenses

被引:29
作者
Polikarpov, Maxim [1 ,2 ]
Snigireva, Irina [2 ]
Snigirev, Anatoly [2 ]
机构
[1] Natl Res Nucl Univ Mephi, Moscow 115409, Russia
[2] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
X-ray refraction; focusing; X-ray refractive lenses; harmonic suppression; MONOCHROMATOR; MIRROR;
D O I
10.1107/S1600577514001003
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method of harmonics rejection based on X-ray refractive optics has been proposed. Taking into account the fact that the focal distance of the refractive lens is energy-dependent, the use of an off-axis illumination of the lens immediately leads to spatial separation of the energy spectrum by focusing the fundamental harmonic at the focal point and suppressing the unfocused high-energy radiation with a screen absorber or slit. The experiment was performed at the ESRF ID06 beamline in the in-line geometry using an X-ray transfocator with compound refractive lenses. Using this technique the presence of the third harmonic has been reduced to 10(-3). In total, our method enabled suppression of all higher-order harmonics to five orders of magnitude using monochromator detuning. The method is well suited to third-generation synchrotron radiation sources and is very promising for the future ultimate storage rings.
引用
收藏
页码:484 / 487
页数:4
相关论文
共 17 条
[1]   PERFECT-CRYSTAL MONOCHROMATORS FOR SYNCHROTRON X-RADIATION [J].
BONSE, U ;
MATERLIK, G ;
SCHRODER, W .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1976, 9 (JUN1) :223-230
[2]   X-ray standing wave microscopy: Chemical microanalysis with atomic resolution [J].
Drakopoulos, M ;
Zegenhagen, J ;
Snigirev, A ;
Snigireva, I ;
Hauser, M ;
Eberl, K ;
Aristov, V ;
Shabelnikov, L ;
Yunkin, V .
APPLIED PHYSICS LETTERS, 2002, 81 (12) :2279-2281
[3]   SEPARATED FUNCTION FOCUSING MONOCHROMATOR SYSTEM FOR SYNCHROTRON RADIATION [J].
HASTINGS, JB ;
KINCAID, BM ;
EISENBERGER, P .
NUCLEAR INSTRUMENTS & METHODS, 1978, 152 (01) :167-171
[4]   Ray tracing study for a detuned nondispersed double crystal monochromator [J].
Hou, ZC .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2005, 76 (01)
[5]   A device for selecting and rejecting X-ray harmonics in synchrotron radiation beams [J].
Karanfil, C ;
Chapman, D ;
Segre, CU ;
Bunker, G .
JOURNAL OF SYNCHROTRON RADIATION, 2004, 11 :393-398
[7]   A SIMPLE IN-HUTCH MIRROR ASSEMBLY FOR X-RAY HARMONIC SUPPRESSION [J].
LATIMER, MJ ;
ROMPEL, A ;
UNDERWOOD, JH ;
YACHANDRA, VK ;
KLEIN, MP .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1843-1845
[8]   A microscope for hard x rays based on parabolic compound refractive lenses [J].
Lengeler, B ;
Schroer, CG ;
Richwin, M ;
Tümmler, J ;
Drakopoulos, M ;
Snigirev, A ;
Snigireva, I .
APPLIED PHYSICS LETTERS, 1999, 74 (26) :3924-3926
[9]   Refractive x-ray lenses [J].
Lengeler, B ;
Schroer, CG ;
Kuhlmann, M ;
Benner, B ;
Guenzler, TF ;
Kurapova, O ;
Zontone, F ;
Snigirev, A ;
Snigireva, I .
JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (10A) :A218-A222
[10]   Double multilayer monochromator for harmonic rejection in the 5-60keV range [J].
Lingham, M ;
Ziegler, E ;
Luken, E ;
Loeffen, P ;
Mullender, S ;
Goulon, J .
MULTILAYER AND GRAZING INCIDENCE X-RAY/EUV OPTICS III, 1996, 2805 :158-168