Finite element analysis of balloon-expandable coronary stent deployment: Influence of angioplasty balloon configuration

被引:65
作者
Martin, David [1 ]
Boyle, Fergal [1 ]
机构
[1] Dublin Inst Technol, Dept Mech Engn, Dublin, Ireland
关键词
finite element analysis; coronary heart disease; stent; angioplasty balloon; restenosis; coronary artery; WALL SHEAR-STRESS; MECHANICAL-PROPERTIES; DESIGN OPTIMIZATION; ELUTING STENTS; ARTERY; IMPLANTATION; BEHAVIOR; SIMULATION; HEMODYNAMICS; RESTENOSIS;
D O I
10.1002/cnm.2557
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Today, the majority of coronary stents are balloon-expandable and are deployed using a balloon-tipped catheter. To improve deliverability, the membrane of the angioplasty balloon is typically folded about the catheter in a pleated configuration. As such, the deployment of the angioplasty balloon is governed by the material properties of the balloon membrane, its folded configuration and its attachment to the catheter. Despite this observation, however, an optimum strategy for modelling the configuration of the angioplasty balloon in finite element studies of coronary stent deployment has not been identified, and idealised models of the angioplasty balloon are commonly employed in the literature. These idealised models often neglect complex geometrical features, such as the folded configuration of the balloon membrane and its attachment to the catheter, which may have a significant influence on the deployment of a stent. In this study, three increasingly sophisticated models of a typical semi-compliant angioplasty balloon were employed to determine the influence of angioplasty balloon configuration on the deployment of a stent. The results of this study indicate that angioplasty balloon configuration has a significant influence on both the transient behaviour of the stent and its impact on the mechanical environment of the coronary artery. Copyright (c) 2013 John Wiley & Sons, Ltd.
引用
收藏
页码:1161 / 1175
页数:15
相关论文
共 59 条
[1]  
Auricchio F., 2001, COMPUT METHOD BIOMEC, V4, P249, DOI DOI 10.1080/10255840108908007
[2]   Effects of different stent designs on local hemodynamics in stented arteries [J].
Balossino, Rossella ;
Gervaso, Francesca ;
Migliavacca, Francesco ;
Dubini, Gabriele .
JOURNAL OF BIOMECHANICS, 2008, 41 (05) :1053-1061
[3]  
Brauer H, 2000, MATERIALWISSENSCHAFT, V30, P876
[4]   Assessment of tissue prolapse after balloon-expandable stenting: Influence of stent cell geometry [J].
Capelli, Claudio ;
Gervaso, Francesca ;
Petrini, Lorenza ;
Dubini, Gabriele ;
Migliavacca, Francesco .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (04) :441-447
[5]   Finite element simulation of slotted tube (stent) with the presence of plaque and artery by balloon expansion [J].
Chua, SND ;
MacDonald, BJ ;
Hashmi, MSJ .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2004, 155 :1772-1779
[6]   Finite element simulation of stent and balloon interaction [J].
Chua, SND ;
Mac Donald, BJ ;
Hashmi, MSJ .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2003, 143 :591-597
[7]   Finite-element simulation of stent expansion [J].
Chua, SND ;
Mac Donald, BJ ;
Hashmi, MSJ .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2002, 120 (1-3) :335-340
[8]   Selection of coronary stents [J].
Colombo, A ;
Stankovic, G ;
Moses, JW .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (06) :1021-1033
[9]   Realistic finite element-based stent design: The impact of balloon folding [J].
De Beule, Matthieu ;
Mortier, Peter ;
Carlier, Stphane G. ;
Verhegghe, Benedict ;
Van Impe, Rudy ;
Verdonck, Pascal .
JOURNAL OF BIOMECHANICS, 2008, 41 (02) :383-389
[10]   Analysis of wall shear stress in stented coronary artery using 3D computational fluid dynamics modeling [J].
Dehlaghi, Vahab ;
Shadpoor, Mohammad Tafazoli ;
Najarian, Siamak .
JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2008, 197 (1-3) :174-181