Pool boiling heat transfer on uniform and non-uniform porous coating surfaces

被引:105
作者
Ji, Xianbing [1 ,2 ]
Xu, Jinliang [1 ,3 ]
Zhao, Ziwei [2 ,3 ]
Yang, Wolong [3 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, Beijing Key Lab Multiphase Flow & Heat Transfer, Beijing 102206, Peoples R China
[3] North China Elect Power Univ, Beijing Key Lab Energy Safety & Clean Utilizat, Beijing 102206, Peoples R China
关键词
Pool boiling; Porous heater surface; Critical heat flux; Boiling pattern; DIELECTRIC LIQUID; ENHANCEMENT; FC-72; MODEL; FLUX;
D O I
10.1016/j.expthermflusci.2013.03.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
Pool boiling heat transfer experiments were performed using acetone as the working fluid at atmospheric pressure on seven heater surfaces, which can be divided into three types. The first, second and third types refer to the plain surface with poor heat transfer, the open channel surface and uniform porous coating surface with moderate heat transfer enhancement, and the 2-D/3-D porous coating surfaces with significant heat transfer enhancement. The open channel surface and uniform porous coating surface had inter-crossed boiling curves, with better performance for the uniform porous coating surface due to the enhanced nucleation heat transfer at small or moderate wall superheats, and better performance for the open channel surface at large wall superheats due to the vapor channel provided. The 2-D porous coating surface with the pitch width of 1.6 mm yields the best heat transfer performance and the largest critical heat fluxes among the three 2-D surfaces. The 3-D porous coating surface (TS#7) significantly increases the critical heat flux, which can be 3.7 times of that for the plain surface. Boiling curves were shifted to smaller wall superheat region and critical heat fluxes were increased with increases in liquid subcoolings. Two distinct bubble patterns existed for 2-D/3-D porous coating surfaces: continuously-isolated-bubble-escape pattern at small or moderate heat fluxes, and periodically-large-bubble-escape pattern at large heat fluxes. The hollow well at the heater center and/or the porous stacks exposed in liquid are acted as the liquid supply duct at high heat fluxes. This explains the reason that the porous coating surfaces with periodically varied particle layer thicknesses had larger critical heat fluxes than other heater surfaces. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:198 / 212
页数:15
相关论文
共 19 条
  • [1] Enhanced boiling heat transfer from microporous surfaces: effects of a coating composition and method
    Chang, JY
    You, SM
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1997, 40 (18) : 4449 - 4460
  • [2] Enhanced boiling of HFE-7100 dielectric liquid on porous graphite
    El-Genk, MS
    Parker, JL
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (15-16) : 2455 - 2481
  • [3] Critical heat flux in thin, uniform particle coatings
    Hwang, GS
    Kaviany, M
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (5-6) : 844 - 849
  • [4] Boiling heat transfer on machined porous surfaces with structural optimization
    Jiang, YY
    Wang, WC
    Wang, D
    Wang, BX
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (02) : 443 - 456
  • [5] Pool boiling enhancement with surface treatments
    Kim, Yoon-Ho
    Lee, Kyu-Jung
    Han, Donghyouck
    [J]. HEAT AND MASS TRANSFER, 2008, 45 (01) : 55 - 60
  • [6] Lee L., 1975, Letters in Heat and Mass Transfer, V2, P315, DOI 10.1016/0094-4548(75)90015-6
  • [7] Evaporative heat transfer model of a loop heat pipe with bidisperse wick structure
    Lin, Fang-Chou
    Liu, Bing-Han
    Huang, Chi-Ting
    Chen, Yau-Ming
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (21-22) : 4621 - 4629
  • [8] Pool-boiling CHF enhancement by modulated porous-layer coating: theory and experiment
    Liter, SG
    Kaviany, M
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2001, 44 (22) : 4287 - 4311
  • [9] The pool boiling heat transfer enhancement from experiments with binary mixtures and porous heating covers
    Meléndez, E
    Reyes, R
    [J]. EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2006, 30 (03) : 185 - 192
  • [10] 2-D and 3-D modulated porous coatings for enhanced pool boiling
    Min, D. H.
    Hwang, G. S.
    Usta, Y.
    Cora, O. N.
    Koc, M.
    Kaviany, M.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (11-12) : 2607 - 2613