Optimal Dual-VENC Unwrapping in Phase-Contrast MRI

被引:14
作者
Carrillo, Hugo [1 ]
Osses, Axel [1 ,2 ]
Uribe, Sergio [2 ,3 ,4 ]
Bertoglio, Cristobal [5 ]
机构
[1] Univ Chile, Ctr Math Modeling, Santiago 8370456, Chile
[2] Millennium Nucleus Cardiovasc Magnet Resonance, Macul 7820436, Chile
[3] Pontificia Univ Catolica, Ctr Biomed Imaging, Santiago 7820436, Chile
[4] Pontificia Univ Catolica, Sch Med, Dept Radiol, Santiago 833002, Chile
[5] Univ Groningen, Bernoulli Inst, NL-9747 AG Groningen, Netherlands
关键词
Phase-contrast MRI; dual-VENC; unwrapping; 4D FLOW MRI;
D O I
10.1109/TMI.2018.2882553
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Dual-VENC strategies have been proposed to improve the velocity-to-noise ratio in phase-contrast MRI. However, they are based on aliasing-free high-VENC data. The aim of this paper is to propose a dual-VENC velocity estimation method allowing high-VENC aliased data. For this purpose, we reformulate the phase-contrast velocity as a least squares estimator, providing a natural framework for including multiple encoding gradient measurements. By analyzing the mathematical properties of both single-and dual-VENCproblems, we can justify theoretically high/low-VENC ratios such that the aliasing velocity can be minimized. The resulting reconstruction algorithm was assessed using three types of data: numerical, experimental, and volunteers. In clinical practice, this method would allow shorter examination times by avoiding tedious adaptation of VENC values by repeated scans.
引用
收藏
页码:1263 / 1270
页数:8
相关论文
共 16 条
[1]   RECONSTRUCTIONS OF PHASE-CONTRAST, PHASED-ARRAY MULTICOIL DATA [J].
BERNSTEIN, MA ;
GRGIC, M ;
BROSNAN, TJ ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :330-334
[2]  
Brown RW., 2014, Magnetic Resonance Imaging: Physical Principles and Sequence Design
[3]   Use of Multi-Velocity Encoding 4D Flow MRI to Improve Quantification of Flow Patterns in the Aorta [J].
Callaghan, Fraser M. ;
Kozor, Rebecca ;
Sherrah, Andrew G. ;
Vallely, Michael ;
Celermajer, David ;
Figtree, Gemma A. ;
Grieve, Stuart M. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (02) :352-363
[4]   4D flow cardiovascular magnetic resonance consensus statement [J].
Dyverfeldt, Petter ;
Bissell, Malenka ;
Barker, Alex J. ;
Bolger, Ann F. ;
Carlhall, Carl-Johan ;
Ebbers, Tino ;
Francios, Christopher J. ;
Frydrychowicz, Alex ;
Geiger, Julia ;
Giese, Daniel ;
Hope, Michael D. ;
Kilner, Philip J. ;
Kozerke, Sebastian ;
Myerson, Saul ;
Neubauer, Stefan ;
Wieben, Oliver ;
Markl, Michael .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2015, 17
[5]   Multi-VENC Acquisition of Four-Dimensional Phase-Contrast MRI to Improve Precision of Velocity Field Measurement [J].
Ha, Hojin ;
Kim, Guk Bae ;
Kweon, Jihoon ;
Kim, Young-Hak ;
Kim, Namkug ;
Yang, Dong Hyun ;
Lee, Sang Joon .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (05) :1909-1919
[6]  
Hirsch S, 2017, MAGNETIC RESONANCE ELASTOGRAPHY: PHYSICAL BACKGROUND AND MEDICAL APPLICATIONS, P1
[7]   3-POINT PHASE-CONTRAST VELOCITY-MEASUREMENTS WITH INCREASED VELOCITY-TO-NOISE RATIO [J].
LEE, AT ;
PIKE, GB ;
PELC, NJ .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) :122-126
[8]   Velocity reconstruction with nonconvex optimization for low-velocity-encoding phase-contrast MRI [J].
Loecher, Michael ;
Ennis, Daniel B. .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) :42-52
[9]   Phase unwrapping in 4D MR flow with a 4D single-step laplacian algorithm [J].
Loecher, Michael ;
Schrauben, Eric ;
Johnson, Kevin M. ;
Wieben, Oliver .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (04) :833-842
[10]   Variability of 4D flow parameters when subjected to changes in MRI acquisition parameters using a realistic thoracic aortic phantom [J].
Montalba, Cristian ;
Urbina, Jesus ;
Sotelo, Julio ;
Andia, Marcelo E. ;
Tejos, Cristian ;
Irarrazaval, Pablo ;
Hurtado, Daniel E. ;
Valverde, Israel ;
Uribe, Sergio .
MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) :1882-1892