Simple, Miniaturized Blood Plasma Extraction Method

被引:104
作者
Kim, Jin-Hee [1 ]
Woenker, Timothy [2 ]
Adamec, Jiri [3 ]
Regnier, Fred E. [1 ,4 ]
机构
[1] Novilytic Labs, W Lafayette, IN 47906 USA
[2] Chematics, North Webster, IN 46555 USA
[3] Univ Nebraska, Dept Biochem, Lincoln, NE 68588 USA
[4] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
关键词
TANDEM MASS-SPECTROMETRY; MICROFLUIDIC DEVICE; STATISTICAL-MODEL; CELL-SEPARATION; WHOLE-BLOOD; CROSS-FLOW; HEMATOCRIT; PROTEINS; SPOTS; CHROMATOGRAPHY;
D O I
10.1021/ac402735y
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid plasma extraction technology that collects a 2.5 mu L aliquot of plasma within three minutes from a finger-stick derived drop of blood was evaluated. The utility of the plasma extraction cards used was that a paper collection disc bearing plasma was produced that could be air-dried in fifteen minutes and placed in a mailing envelop for transport to an analytical laboratory. This circumvents the need for venipuncture and blood collection in specialized vials by a phlebotomist along with centrifugation and refrigerated storage. Plasma extraction was achieved by applying a blood drop to a membrane stack through which plasma was drawn by capillary action. During the course of plasma migration to a collection disc at the bottom of the membrane stack blood cells were removed by a combination of adsorption and filtration. After the collection disc filled with an aliquot of plasma the upper membranes were stripped from the collection card and the collection disc was air-dried. Intercard differences in the volume of plasma collected varied approximately 1% while volume variations of less than 2% were seen with hematocrit levels ranging from 20% to 71%. Dried samples bearing metabolites and proteins were then extracted from the disc and analyzed. 25-Hydroxy vitamin D was quantified by LC-MS/MS analysis following derivatization with a secosteroid signal enhancing tag that imparted a permanent positive charge to the vitamin and reduced the limit of quantification (LOQ) to 1 pg of collected vitamin on the disc; comparable to values observed with liquid liquid extraction (LLE) of a venipuncture sample. A similar study using conventional proteomics methods and spectral counting for quantification was conducted with yeast enolase added to serum as an internal standard. The LOQ with extracted serum samples for enolase was 1 mu M, linear from 1 to 40 mu M, the highest concentration examined. In all respects protein quantification with extracted serum samples was comparable to that observed with serum samples obtained by venipuncture.
引用
收藏
页码:11501 / 11508
页数:8
相关论文
共 48 条
[1]   Mass spectrometric quantitation of peptides and proteins using stable isotope standards and capture by anti-peptide antibodies (SISCAPA) [J].
Anderson, NL ;
Anderson, NG ;
Haines, LR ;
Hardie, DB ;
Olafson, RW ;
Pearson, TW .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (02) :235-244
[2]   Microfluidics for cell separation [J].
Bhagat, Ali Asgar S. ;
Bow, Hansen ;
Hou, Han Wei ;
Tan, Swee Jin ;
Han, Jongyoon ;
Lim, Chwee Teck .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (10) :999-1014
[3]   Separation of blood cells and plasma in microchannel bend structures [J].
Blattert, C ;
Jurischka, R ;
Schoth, A ;
Kerth, P ;
Menz, W .
LAB - ON - A - CHIP: PLATFORMS, DEVICES, AND APPLICATIONS, 2004, 5591 :143-151
[4]   Microfluidic chip for blood cell separation and collection based on crossflow filtration [J].
Chen, Xing ;
Cui, Da Fu ;
Liu, Chang Chun ;
Li, Hui .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 130 (01) :216-221
[5]   Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications [J].
Crowley, TA ;
Pizziconi, V .
LAB ON A CHIP, 2005, 5 (09) :922-929
[6]   The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs [J].
Denniff, Philip ;
Spooner, Neil .
BIOANALYSIS, 2010, 2 (08) :1385-1395
[7]   Tryptic Peptide Analysis of Ceruloplasmin in Dried Blood Spots Using Liquid Chromatography-Tandem Mass Spectrometry: Application to Newborn Screening [J].
Dewilde, Amy ;
Sadilkova, Katerina ;
Sadilek, Martin ;
Vasta, Valeria ;
Hahn, Si Houn .
CLINICAL CHEMISTRY, 2008, 54 (12) :1961-1968
[8]   EFFECTS OF DIETARY-PROTEIN, FAT AND ENERGY ON BLOOD HEMOGLOBIN AND HEMATOCRIT IN RAT [J].
EDOZIEN, JC ;
SWITZER, BR .
JOURNAL OF NUTRITION, 1977, 107 (06) :1016-1021
[9]   Top-Down Proteomics and Direct Surface Sampling of Neonatal Dried Blood Spots: Diagnosis of Unknown Hemoglobin Variants [J].
Edwards, Rebecca L. ;
Griffiths, Paul ;
Bunch, Josephine ;
Cooper, Helen J. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2012, 23 (11) :1921-1930
[10]   SCREENING FOR POMPE DISEASE USING A RAPID DRIED BLOOD SPOT METHOD: EXPERIENCE OF A CLINICAL DIAGNOSTIC LABORATORY [J].
Goldstein, Jennifer L. ;
Young, Sarah P. ;
Changela, Mohita ;
Dickerson, Gwen H. ;
Zhang, Haoyue ;
Dai, Jian ;
Peterson, Denise ;
Millington, David S. ;
Kishnani, Priya S. ;
Bali, Deeksha S. .
MUSCLE & NERVE, 2009, 40 (01) :32-36